↑ Parent Menu⌂ Main Menu
← Railway Ground Hazard Risk Management
GHRM
Railway Ground Hazard Risk Management · 2.0 · The Underworld
Sections · click a car to open it

Chapter 2.3 — Track Substructure: Ballast, Subballast and Subgrade

Formerly Geo Rail Chapter 6.3 — Railroad Track Subgrade: Special Topics

The track subgrade is the engineered foundation upon which the entire superstructure — rail, ties, ballast, and subballast — rests.
Authors: Daniel P. Colwell and Mario Ruel

Geotechnical Services Manual for Railroad Clients

A Consultant's Reference for Delivering Geotechnical Engineering Services Across North American Railroad Capital Programs

Typical Values for This Chapter — from the GHRM Soil & Rock Properties Database

Subgrade support, compaction, frost, ballast and subballast values for track substructure design. English units; every value cites its library source, table and page. For preliminary design and checking test results, not a substitute for site testing.

Subgrade support (CBR and IBR) (35 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
California bearing ratio (soaked, design)Competent broken rock, gravel sizesGW, GPDrainage: All20%LOOK T13.9, p.183
California bearing ratio (soaked, design)Competent broken rock with some fines; gravels, sandsGM, GC, SW, SPDrainage: All15%LOOK T13.9, p.183
California bearing ratio (soaked, design)Sands, silty or clayeySM, SCDrainage: Good10%LOOK T13.9, p.183
California bearing ratio (soaked, design)Sands, silty or clayeySM, SCDrainage: Poor7%LOOK T13.9, p.183
California bearing ratio (soaked, design)Inorganic silts, low plasticityMLDrainage: Poor5%LOOK T13.9, p.183
California bearing ratio (soaked, design)Inorganic silts (high plasticity) and claysMH, CL, CHDrainage: Good3%LOOK T13.9, p.183
California bearing ratio (soaked, design)Inorganic silts (high plasticity) and claysMH, CL, CHDrainage: Poor3%LOOK T13.9, p.183
California bearing ratioHeavy clayPI = 70; water table >2 ft below formation2%CB T7.2, p.166
California bearing ratioHeavy clayPI = 70; water table <2 ft below formation1%CB T7.2, p.166
California bearing ratioHeavy clayPI = 60; water table >2 ft below formation2%CB T7.2, p.166
California bearing ratioHeavy clayPI = 60; water table <2 ft below formation1.5%CB T7.2, p.166
California bearing ratioHeavy clayPI = 50; water table >2 ft below formation2.5%CB T7.2, p.166
California bearing ratioHeavy clayPI = 50; water table <2 ft below formation2%CB T7.2, p.166
California bearing ratioHeavy clayPI = 40; water table >2 ft below formation3%CB T7.2, p.166
California bearing ratioHeavy clayPI = 40; water table <2 ft below formation2%CB T7.2, p.166
California bearing ratioSilty clayPI = 30; water table >2 ft below formation5%CB T7.2, p.166
California bearing ratioSilty clayPI = 30; water table <2 ft below formation3%CB T7.2, p.166
California bearing ratioSilty clayPI = 20; water table >2 ft below formation6%CB T7.2, p.166
California bearing ratioSilty clayPI = 20; water table <2 ft below formation4%CB T7.2, p.166
California bearing ratioSilty clayPI = 10; water table >2 ft below formation7%CB T7.2, p.166
California bearing ratioSilty clayPI = 10; water table <2 ft below formation5%CB T7.2, p.166
California bearing ratioSiltWater table >2 ft below formation2%CB T7.2, p.166
California bearing ratioSiltWater table <2 ft below formation1%CB T7.2, p.166
California bearing ratioSand, poorly gradedNon-plastic; water table >2 ft below formation20%CB T7.2, p.166
California bearing ratioSand, poorly gradedNon-plastic; water table <2 ft below formation10%CB T7.2, p.166
California bearing ratioSand, well gradedNon-plastic; water table >2 ft below formation40%CB T7.2, p.166
California bearing ratioSand, well gradedNon-plastic; water table <2 ft below formation15%CB T7.2, p.166
California bearing ratioSandy gravel, well gradedNon-plastic; water table >2 ft below formation60%CB T7.2, p.166
California bearing ratioSandy gravel, well gradedNon-plastic; water table <2 ft below formation20%CB T7.2, p.166
Illinois bearing ratioIllinois soilsA-11527.540%IDOT T5.5.16-1, p.184
Illinois bearing ratioIllinois soilsA-2-4, A-2-581420%IDOT T5.5.16-1, p.184
Illinois bearing ratioIllinois soilsA-2-6, A-2-761320%IDOT T5.5.16-1, p.184
Illinois bearing ratioIllinois soilsA-351015%IDOT T5.5.16-1, p.184
Illinois bearing ratioIllinois soilsA-4, A-5, A-62610%IDOT T5.5.16-1, p.184
Illinois bearing ratioIllinois soilsA-7-5, A-7-614.58%IDOT T5.5.16-1, p.184
Open this set in the database ↗
Compaction by USCS class (28 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
Maximum dry unit weightGravel–sand, well graded, cleanGWAASHTO T 99127.3132.1136.9pcfCB T3.2, p.80
Optimum moisture contentGravel–sand, well graded, cleanGWAASHTO T 9989.511%CB T3.2, p.80
Maximum dry unit weightGravel–sand, poorly graded, cleanGPAASHTO T 99117.8122.5127.3pcfCB T3.2, p.80
Optimum moisture contentGravel–sand, poorly graded, cleanGPAASHTO T 991112.514%CB T3.2, p.80
Maximum dry unit weightGravel–sand, well graded, small silt contentGMAASHTO T 99121128.9136.9pcfCB T3.2, p.80
Optimum moisture contentGravel–sand, well graded, small silt contentGMAASHTO T 9981012%CB T3.2, p.80
Maximum dry unit weightGravel–sand, well graded, small clay contentGCAASHTO T 99117.8122.5127.3pcfCB T3.2, p.80
Optimum moisture contentGravel–sand, well graded, small clay contentGCAASHTO T 99911.514%CB T3.2, p.80
Maximum dry unit weightSand, well graded, cleanSWAASHTO T 99111.4122.5133.7pcfCB T3.2, p.80
Optimum moisture contentSand, well graded, cleanSWAASHTO T 99912.516%CB T3.2, p.80
Maximum dry unit weightSand, poorly graded, small silt contentSPAASHTO T 99101.9111.5121pcfCB T3.2, p.80
Optimum moisture contentSand, poorly graded, small silt contentSPAASHTO T 991216.521%CB T3.2, p.80
Maximum dry unit weightSand, well graded, small silt contentSMAASHTO T 99111.4119.3127.3pcfCB T3.2, p.80
Optimum moisture contentSand, well graded, small silt contentSMAASHTO T 991113.516%CB T3.2, p.80
Maximum dry unit weightSand, well graded, small clay contentSCAASHTO T 99108.2117.8127.3pcfCB T3.2, p.80
Optimum moisture contentSand, well graded, small clay contentSCAASHTO T 99111519%CB T3.2, p.80
Maximum dry unit weightSilts, low plasticityMLAASHTO T 9995.5108.2121pcfCB T3.2, p.80
Optimum moisture contentSilts, low plasticityMLAASHTO T 99121824%CB T3.2, p.80
Maximum dry unit weightClays, low plasticityCLAASHTO T 9995.5108.2121pcfCB T3.2, p.80
Optimum moisture contentClays, low plasticityCLAASHTO T 99121824%CB T3.2, p.80
Maximum dry unit weightOrganic silts, low plasticityOLAASHTO T 9982.892.3101.9pcfCB T3.2, p.80
Optimum moisture contentOrganic silts, low plasticityOLAASHTO T 992126.532%CB T3.2, p.80
Maximum dry unit weightSilts, high plasticityMHAASHTO T 997082.895.5pcfCB T3.2, p.80
Optimum moisture contentSilts, high plasticityMHAASHTO T 99243240%CB T3.2, p.80
Maximum dry unit weightClays, high plasticityCHAASHTO T 9982.895.5108.2pcfCB T3.2, p.80
Optimum moisture contentClays, high plasticityCHAASHTO T 991927.536%CB T3.2, p.80
Maximum dry unit weightOrganic silts/clays, high plasticityOHAASHTO T 9966.884.3101.9pcfCB T3.2, p.80
Optimum moisture contentOrganic silts/clays, high plasticityOHAASHTO T 99213345%CB T3.2, p.80
Open this set in the database ↗
Frost susceptibility (5 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
Frost susceptibility groupAll soils with less than 3% finer than 0.02 mmNFSNFSCB T9.2, p.197
Frost susceptibility groupGravelly soils: 3–20% finer than 0.02 mmF1F1CB T9.2, p.197
Frost susceptibility groupSands: 3–15% finer than 0.02 mmF2F2CB T9.2, p.197
Frost susceptibility groupGravelly soils with >20% finer than 0.02 mm; sands (except silty fine sands) with >15% finer; clays with PI > 12; varved clays with uniform conditionsF3F3CB T9.2, p.197
Frost susceptibility groupSilts, including sandy silts; fine silty sands with >15% finer than 0.02 mm; lean clays with PI < 12; varved clays with non-uniform conditionsF4F4CB T9.2, p.197
Open this set in the database ↗
Coefficient of subgrade reaction (8 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
Coefficient of subgrade reaction (1-ft plate)Loose sand18.438.658.9pciROB T9, p.84
Coefficient of subgrade reaction (1-ft plate)Medium dense sand36.8165.8294.7pciROB T9, p.84
Coefficient of subgrade reaction (1-ft plate)Dense sand221340.8460.5pciROB T9, p.84
Coefficient of subgrade reaction (1-ft plate)Clayey sand110.5202.6294.7pciROB T9, p.84
Coefficient of subgrade reaction (1-ft plate)Silty sand73.7128.9184.2pciROB T9, p.84
Coefficient of subgrade reaction (1-ft plate)Clayey soil, su < 1,044 psf (50 kPa)36.855.273.7pciROB T9, p.84
Coefficient of subgrade reaction (1-ft plate)Clayey soil, su 1,044–2,089 psf (50–100 kPa)73.7128.9184.2pciROB T9, p.84
Coefficient of subgrade reaction (1-ft plate)Clayey soil, su > 2,089 psf (100 kPa)184.2pciROB T9, p.84
Open this set in the database ↗
Ballast acceptance limits (AREMA) (28 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
Ballast – material passing No. 200 sieveBallast – Granite and traprockAREMA limit (max); ASTM C1171%AREMA19 T1-2-1, p.1-2-11
Ballast – material passing No. 200 sieveBallast – QuartziteAREMA limit (max); ASTM C1171%AREMA19 T1-2-1, p.1-2-11
Ballast – material passing No. 200 sieveBallast – LimestoneAREMA limit (max); ASTM C1171%AREMA19 T1-2-1, p.1-2-11
Ballast – material passing No. 200 sieveBallast – Dolomitic limestoneAREMA limit (max); ASTM C1171%AREMA19 T1-2-1, p.1-2-11
Ballast – bulk specific gravityBallast – Granite and traprockAREMA limit (min); ASTM C1272.6–AREMA19 T1-2-1, p.1-2-11
Ballast – bulk specific gravityBallast – QuartziteAREMA limit (min); ASTM C1272.6–AREMA19 T1-2-1, p.1-2-11
Ballast – bulk specific gravityBallast – LimestoneAREMA limit (min); ASTM C1272.6–AREMA19 T1-2-1, p.1-2-11
Ballast – bulk specific gravityBallast – Dolomitic limestoneAREMA limit (min); ASTM C1272.65–AREMA19 T1-2-1, p.1-2-11
Ballast – absorptionBallast – Granite and traprockAREMA limit (max); ASTM C1271%AREMA19 T1-2-1, p.1-2-11
Ballast – absorptionBallast – QuartziteAREMA limit (max); ASTM C1271%AREMA19 T1-2-1, p.1-2-11
Ballast – absorptionBallast – LimestoneAREMA limit (max); ASTM C1272%AREMA19 T1-2-1, p.1-2-11
Ballast – absorptionBallast – Dolomitic limestoneAREMA limit (max); ASTM C1272%AREMA19 T1-2-1, p.1-2-11
Ballast – clay lumps and friable particlesBallast – Granite and traprockAREMA limit (max); ASTM C1420.5%AREMA19 T1-2-1, p.1-2-11
Ballast – clay lumps and friable particlesBallast – QuartziteAREMA limit (max); ASTM C1420.5%AREMA19 T1-2-1, p.1-2-11
Ballast – clay lumps and friable particlesBallast – LimestoneAREMA limit (max); ASTM C1420.5%AREMA19 T1-2-1, p.1-2-11
Ballast – clay lumps and friable particlesBallast – Dolomitic limestoneAREMA limit (max); ASTM C1420.5%AREMA19 T1-2-1, p.1-2-11
Ballast – Los Angeles abrasion loss (LAA)Ballast – Granite and traprockAREMA limit (max); ASTM C535 or C13135%AREMA19 T1-2-1, p.1-2-11
Ballast – Los Angeles abrasion loss (LAA)Ballast – QuartziteAREMA limit (max); ASTM C535 or C13130%AREMA19 T1-2-1, p.1-2-11
Ballast – Los Angeles abrasion loss (LAA)Ballast – LimestoneAREMA limit (max); ASTM C535 or C13130%AREMA19 T1-2-1, p.1-2-11
Ballast – Los Angeles abrasion loss (LAA)Ballast – Dolomitic limestoneAREMA limit (max); ASTM C535 or C13130%AREMA19 T1-2-1, p.1-2-11
Ballast – sodium sulfate soundness, 5 cyclesBallast – Granite and traprockAREMA limit (max); ASTM C885%AREMA19 T1-2-1, p.1-2-11
Ballast – sodium sulfate soundness, 5 cyclesBallast – QuartziteAREMA limit (max); ASTM C885%AREMA19 T1-2-1, p.1-2-11
Ballast – sodium sulfate soundness, 5 cyclesBallast – LimestoneAREMA limit (max); ASTM C885%AREMA19 T1-2-1, p.1-2-11
Ballast – sodium sulfate soundness, 5 cyclesBallast – Dolomitic limestoneAREMA limit (max); ASTM C885%AREMA19 T1-2-1, p.1-2-11
Ballast – flat or elongated particlesBallast – Granite and traprockAREMA limit (max); ASTM D4791 Method A5%AREMA19 T1-2-1, p.1-2-11
Ballast – flat or elongated particlesBallast – QuartziteAREMA limit (max); ASTM D4791 Method A5%AREMA19 T1-2-1, p.1-2-11
Ballast – flat or elongated particlesBallast – LimestoneAREMA limit (max); ASTM D4791 Method A5%AREMA19 T1-2-1, p.1-2-11
Ballast – flat or elongated particlesBallast – Dolomitic limestoneAREMA limit (max); ASTM D4791 Method A5%AREMA19 T1-2-1, p.1-2-11
Open this set in the database ↗
Ballast gradations (AREMA) (40 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
Ballast gradation – percent passing 3" sieveAREMA No. 24 ballast (2½"–¾")Main line ballast100%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing 2½" sieveAREMA No. 24 ballast (2½"–¾")Main line ballast9095100%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing 1½" sieveAREMA No. 24 ballast (2½"–¾")Main line ballast2542.560%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing ¾" sieveAREMA No. 24 ballast (2½"–¾")Main line ballast0510%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing ½" sieveAREMA No. 24 ballast (2½"–¾")Main line ballast02.55%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing 3" sieveAREMA No. 25 ballast (2½"–⅜")Main line ballast100%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing 2½" sieveAREMA No. 25 ballast (2½"–⅜")Main line ballast8090100%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing 2" sieveAREMA No. 25 ballast (2½"–⅜")Main line ballast6072.585%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing 1½" sieveAREMA No. 25 ballast (2½"–⅜")Main line ballast506070%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing 1" sieveAREMA No. 25 ballast (2½"–⅜")Main line ballast2537.550%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing ½" sieveAREMA No. 25 ballast (2½"–⅜")Main line ballast512.520%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing ⅜" sieveAREMA No. 25 ballast (2½"–⅜")Main line ballast0510%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing No. 4 sieveAREMA No. 25 ballast (2½"–⅜")Main line ballast01.53%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing 2½" sieveAREMA No. 3 ballast (2"–1")Main line ballast100%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing 2" sieveAREMA No. 3 ballast (2"–1")Main line ballast9597.5100%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing 1½" sieveAREMA No. 3 ballast (2"–1")Main line ballast3552.570%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing 1" sieveAREMA No. 3 ballast (2"–1")Main line ballast07.515%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing ½" sieveAREMA No. 3 ballast (2"–1")Main line ballast02.55%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing 2½" sieveAREMA No. 4A ballast (2"–¾")Main line ballast100%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing 2" sieveAREMA No. 4A ballast (2"–¾")Main line ballast9095100%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing 1½" sieveAREMA No. 4A ballast (2"–¾")Main line ballast607590%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing 1" sieveAREMA No. 4A ballast (2"–¾")Main line ballast1022.535%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing ¾" sieveAREMA No. 4A ballast (2"–¾")Main line ballast0510%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing ⅜" sieveAREMA No. 4A ballast (2"–¾")Main line ballast01.53%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing 2" sieveAREMA No. 4 ballast (1½"–¾")Main line ballast100%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing 1½" sieveAREMA No. 4 ballast (1½"–¾")Main line ballast9095100%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing 1" sieveAREMA No. 4 ballast (1½"–¾")Main line ballast2037.555%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing ¾" sieveAREMA No. 4 ballast (1½"–¾")Main line ballast07.515%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing ⅜" sieveAREMA No. 4 ballast (1½"–¾")Main line ballast02.55%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing 1½" sieveAREMA No. 5 ballast (1"–⅜")Yard ballast100%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing 1" sieveAREMA No. 5 ballast (1"–⅜")Yard ballast9095100%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing ¾" sieveAREMA No. 5 ballast (1"–⅜")Yard ballast4057.575%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing ½" sieveAREMA No. 5 ballast (1"–⅜")Yard ballast152535%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing ⅜" sieveAREMA No. 5 ballast (1"–⅜")Yard ballast07.515%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing No. 4 sieveAREMA No. 5 ballast (1"–⅜")Yard ballast02.55%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing 1½" sieveAREMA No. 57 ballast (1"–No. 4)Yard ballast100%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing 1" sieveAREMA No. 57 ballast (1"–No. 4)Yard ballast9597.5100%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing ½" sieveAREMA No. 57 ballast (1"–No. 4)Yard ballast2542.560%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing No. 4 sieveAREMA No. 57 ballast (1"–No. 4)Yard ballast0510%AREMA19 T1-2-2, p.1-2-12
Ballast gradation – percent passing No. 8 sieveAREMA No. 57 ballast (1"–No. 4)Yard ballast02.55%AREMA19 T1-2-2, p.1-2-12
Open this set in the database ↗
Ballast fouling: categories, sources and intervention limits (29 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
Fouling index FI = P4 + P200Ballast – CleanSelig & Waters categories1%AREMA19 T1-2-3, p.1-2-15
Fouling ratio (volume of fouling / volume of ballast voids basis)Ballast – CleanIndraratna (2006) categories2%MATC T5.1.2, p.52
Fouling index FI = P4 + P200Ballast – Moderately cleanSelig & Waters categories15.510%AREMA19 T1-2-3, p.1-2-15
Fouling ratio (volume of fouling / volume of ballast voids basis)Ballast – Moderately cleanIndraratna (2006) categories2610%MATC T5.1.2, p.52
Fouling index FI = P4 + P200Ballast – Moderately fouledSelig & Waters categories101520%AREMA19 T1-2-3, p.1-2-15
Single-sieve criterion – percent passing ¾-in. sieveBallast – Moderately fouledSingle-sieve field test2532.540%LI16 T3.4, p.86
Fouling ratio (volume of fouling / volume of ballast voids basis)Ballast – Moderately fouledIndraratna (2006) categories101520%MATC T5.1.2, p.52
Fouling index FI = P4 + P200Ballast – FouledSelig & Waters categories203040%AREMA19 T1-2-3, p.1-2-15
Single-sieve criterion – percent passing ¾-in. sieveBallast – FouledSingle-sieve field test404550%LI16 T3.4, p.86
Fouling ratio (volume of fouling / volume of ballast voids basis)Ballast – FouledIndraratna (2006) categories203550%MATC T5.1.2, p.52
Fouling index FI = P4 + P200Ballast – Highly fouledSelig & Waters categories40%AREMA19 T1-2-3, p.1-2-15
Single-sieve criterion – percent passing ¾-in. sieveBallast – Highly fouledSingle-sieve field test50%LI16 T3.4, p.86
Fouling ratio (volume of fouling / volume of ballast voids basis)Ballast – Highly fouledIndraratna (2006) categories50%MATC T5.1.2, p.52
Ballast cleaning intervention limitSelig & Waters – Fouling indexHighly fouled – clean or undercut40%LI16 T3.5, p.86
Ballast cleaning intervention limitSelig & Waters – Fouling indexDrainage reduction30%LI16 T3.5, p.86
Ballast cleaning intervention limitSpoornet – FI(Spoornet)Gradation change80%LI16 T3.5, p.86
Ballast cleaning intervention limitA Class I railroad (Ruel) – Percent passing ¾ in. (19 mm)Highly fouled40%LI16 T3.5, p.86
Ballast cleaning intervention limitUIC – Percent passing ½ in. (14 mm)–30%LI16 T3.5, p.86
Ballast cleaning intervention limitERRI – Percent passing ⅞ in. (22.4 mm)–30%LI16 T3.5, p.86
Ballast hydraulic conductivity by fouling categoryBallast – CleanParsons (1990)2.5×10⁰3.6×10⁰5.1×10⁰cm/sLI16 T6.2, p.279
Ballast hydraulic conductivity by fouling categoryBallast – Moderately cleanParsons (1990)2.5×10⁻¹7.9×10⁻¹2.5×10⁰cm/sLI16 T6.2, p.279
Ballast hydraulic conductivity by fouling categoryBallast – Moderately fouledParsons (1990)1.5×10⁻¹1.9×10⁻¹2.5×10⁻¹cm/sLI16 T6.2, p.279
Ballast hydraulic conductivity by fouling categoryBallast – FouledParsons (1990)5.0×10⁻⁴8.7×10⁻³1.5×10⁻¹cm/sLI16 T6.2, p.279
Ballast hydraulic conductivity by fouling categoryBallast – Highly fouledParsons (1990)5.0×10⁻⁴cm/sLI16 T6.2, p.279
Source of ballast fouling (share by weight)Ballast breakdownAverage of North American sites76%SELIG Fig. 8.33, p.8.25
Source of ballast fouling (share by weight)Infiltration from underlying granular layersAverage of North American sites13%SELIG Fig. 8.33, p.8.25
Source of ballast fouling (share by weight)Ballast surface (spillage, wind-blown)Average of North American sites7%SELIG Fig. 8.33, p.8.25
Source of ballast fouling (share by weight)Subgrade infiltrationAverage of North American sites3%SELIG Fig. 8.33, p.8.25
Source of ballast fouling (share by weight)Tie wearAverage of North American sites1%SELIG Fig. 8.33, p.8.25
Open this set in the database ↗
Fouled ballast: permeability, resistivity and strength (53 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
Ballast hydraulic conductivity by fouling categoryBallast – CleanParsons (1990)2.5×10⁰3.6×10⁰5.1×10⁰cm/sLI16 T6.2, p.279
Ballast hydraulic conductivity by fouling categoryBallast – Moderately cleanParsons (1990)2.5×10⁻¹7.9×10⁻¹2.5×10⁰cm/sLI16 T6.2, p.279
Ballast hydraulic conductivity by fouling categoryBallast – Moderately fouledParsons (1990)1.5×10⁻¹1.9×10⁻¹2.5×10⁻¹cm/sLI16 T6.2, p.279
Ballast hydraulic conductivity by fouling categoryBallast – FouledParsons (1990)5.0×10⁻⁴8.7×10⁻³1.5×10⁻¹cm/sLI16 T6.2, p.279
Ballast hydraulic conductivity by fouling categoryBallast – Highly fouledParsons (1990)5.0×10⁻⁴cm/sLI16 T6.2, p.279
Permeability of fouled ballastBallast fouled with coal dustFouling ratio 10%4.9×10⁻¹cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with crushed ballast finesFouling ratio 20%2.3×10⁰cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with clayFouling ratio 20%6.3×10⁻¹cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with coal dustFouling ratio 20%1.1×10⁻¹cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with crushed ballast finesFouling ratio 30%1.1×10⁰cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with clayFouling ratio 30%1.8×10⁻¹cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with coal dustFouling ratio 30%9.6×10⁻²cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with crushed ballast finesFouling ratio 40%3.8×10⁻¹cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with clayFouling ratio 40%8.1×10⁻²cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with coal dustFouling ratio 40%8.7×10⁻²cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with crushed ballast finesFouling ratio 50%1.7×10⁻¹cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with clayFouling ratio 50%6.1×10⁻²cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with coal dustFouling ratio 50%5.4×10⁻²cm/sMATC T5.1.1, p.48
Electrical resistivity of fouled ballastBallast fouled with coal dustFouling ratio 10%, 18 h40,000ohm-cmMATC T5.2.4, p.57
Electrical resistivity of fouled ballastBallast fouled with crushed ballast finesFouling ratio 20%, 18 h73,000ohm-cmMATC T5.2.4, p.57
Electrical resistivity of fouled ballastBallast fouled with clayFouling ratio 20%, 18 h23,630ohm-cmMATC T5.2.4, p.57
Electrical resistivity of fouled ballastBallast fouled with coal dustFouling ratio 20%, 18 h26,000ohm-cmMATC T5.2.4, p.57
Electrical resistivity of fouled ballastBallast fouled with crushed ballast finesFouling ratio 30%, 18 h40,500ohm-cmMATC T5.2.4, p.57
Electrical resistivity of fouled ballastBallast fouled with clayFouling ratio 30%, 18 h19,202ohm-cmMATC T5.2.4, p.57
Electrical resistivity of fouled ballastBallast fouled with coal dustFouling ratio 30%, 18 h15,800ohm-cmMATC T5.2.4, p.57
Electrical resistivity of fouled ballastBallast fouled with crushed ballast finesFouling ratio 40%, 18 h18,000ohm-cmMATC T5.2.4, p.57
Electrical resistivity of fouled ballastBallast fouled with clayFouling ratio 40%, 18 h14,375ohm-cmMATC T5.2.4, p.57
Electrical resistivity of fouled ballastBallast fouled with coal dustFouling ratio 40%, 18 h11,500ohm-cmMATC T5.2.4, p.57
Electrical resistivity of fouled ballastBallast fouled with crushed ballast finesFouling ratio 50%, 18 h11,000ohm-cmMATC T5.2.4, p.57
Electrical resistivity of fouled ballastBallast fouled with clayFouling ratio 50%, 18 h8,500ohm-cmMATC T5.2.4, p.57
Electrical resistivity of fouled ballastBallast fouled with coal dustFouling ratio 50%, 18 h8,000ohm-cmMATC T5.2.4, p.57
Friction angle of fouled ballast (large direct shear)Clean ballastClean53degMATC T5.5.1, p.88
Friction angle of fouled ballast (large direct shear)Ballast fouled with coal dustFouling ratio 10%35.5degMATC T5.5.1, p.88
Friction angle of fouled ballast (large direct shear)Ballast fouled with coal dustFouling ratio 20%35.4degMATC T5.5.1, p.88
Friction angle of fouled ballast (large direct shear)Ballast fouled with coal dustFouling ratio 30%37degMATC T5.5.1, p.88
Friction angle of fouled ballast (large direct shear)Ballast fouled with coal dustFouling ratio 40%33degMATC T5.5.1, p.88
Friction angle of fouled ballast (large direct shear)Ballast fouled with coal dustFouling ratio 50%22.1degMATC T5.5.1, p.88
Friction angle of fouled ballast (large direct shear)Ballast fouled with crushed ballast finesFouling ratio 20%47degMATC T5.5.1, p.88
Friction angle of fouled ballast (large direct shear)Ballast fouled with crushed ballast finesFouling ratio 30%45.8degMATC T5.5.1, p.88
Friction angle of fouled ballast (large direct shear)Ballast fouled with crushed ballast finesFouling ratio 40%48.2degMATC T5.5.1, p.88
Friction angle of fouled ballast (large direct shear)Ballast fouled with crushed ballast finesFouling ratio 50%39.7degMATC T5.5.1, p.88
Friction angle of fouled ballast (large direct shear)Ballast fouled with clayFouling ratio 20%49degMATC T5.5.1, p.88
Friction angle of fouled ballast (large direct shear)Ballast fouled with clayFouling ratio 30%37.6degMATC T5.5.1, p.88
Friction angle of fouled ballast (large direct shear)Ballast fouled with clayFouling ratio 40%33degMATC T5.5.1, p.88
Friction angle of fouled ballast (large direct shear)Ballast fouled with clayFouling ratio 50%30.1degMATC T5.5.1, p.88
Hydraulic conductivity of fouled ballast – crushed-ballast finesBallast fouled with crushed ballast fines20% fouling2.3×10⁰cm/sPARSONS15 T5.1, p.33
Hydraulic conductivity of fouled ballast – clay finesBallast fouled with clay20% fouling6.3×10⁻¹cm/sPARSONS15 T5.1, p.33
Hydraulic conductivity of fouled ballast – crushed-ballast finesBallast fouled with crushed ballast fines30% fouling1.1×10⁰cm/sPARSONS15 T5.1, p.33
Hydraulic conductivity of fouled ballast – clay finesBallast fouled with clay30% fouling1.8×10⁻¹cm/sPARSONS15 T5.1, p.33
Hydraulic conductivity of fouled ballast – crushed-ballast finesBallast fouled with crushed ballast fines40% fouling3.8×10⁻¹cm/sPARSONS15 T5.1, p.33
Hydraulic conductivity of fouled ballast – clay finesBallast fouled with clay40% fouling8.1×10⁻²cm/sPARSONS15 T5.1, p.33
Hydraulic conductivity of fouled ballast – crushed-ballast finesBallast fouled with crushed ballast fines50% fouling1.7×10⁻¹cm/sPARSONS15 T5.1, p.33
Hydraulic conductivity of fouled ballast – clay finesBallast fouled with clay50% fouling6.1×10⁻²cm/sPARSONS15 T5.1, p.33
Open this set in the database ↗
Ballast and subballast properties (17 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
Ballast friction angleClean ballast4047.555degLI16 T3.6, p.89
Ballast lateral stress ratio (residual)Clean ballast15.510–LI16 T3.6, p.89
Ballast resilient modulusClean ballast205080ksiLI16 T3.6, p.89
Ballast Poisson's ratioClean ballast0.3–LI16 T3.6, p.89
Ballast unit weightBallast – LooseFouling index 095pcfLI16 T3.7, p.90
Ballast unit weightBallast – CompactFouling index 0110pcfLI16 T3.7, p.90
Ballast unit weightBallast – Moderately fouledFouling index 20125pcfLI16 T3.7, p.90
Ballast unit weightBallast – Heavily fouledFouling index 40135pcfLI16 T3.7, p.90
Subballast friction angleSubballast2532.540degLI16 T3.8, p.105
Subballast lateral stress ratioSubballast0.40.71–LI16 T3.8, p.105
Subballast resilient modulusSubballast811.515ksiLI16 T3.8, p.105
Subballast Poisson's ratioSubballast0.30.350.4–LI16 T3.8, p.105
Subballast minimum permeabilitySubballastMinimum1.2×10⁻¹cm/sLI16 T3.8, p.105
Subballast fines (passing No. 200)SubballastAREMA maximum5%AREMA19 text, p.1-2-25
Subballast LA abrasion lossSubballastReasonable acceptance limit50%LI16 text, p.105
Subballast sodium sulfate soundness lossSubballastReasonable acceptance limit5%LI16 text, p.105
Subgrade fines content requiring subballastUFC 4-860-01 track structure85% silt and clayUFC486001 text, p.60
Open this set in the database ↗
Subballast filter criteria (5 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
Filter ratio R50 = D50 filter / D50 protected soilSubballast over subgrade – Uniform grain size (Cu 3 to 4)After USBR (1963)57.510–AREMA19 T1-2-4, p.1-2-25
Filter ratio R50 = D50 filter / D50 protected soilSubballast over subgrade – Well to poorly graded, subrounded grainsAfter USBR (1963)123558–AREMA19 T1-2-4, p.1-2-25
Filter ratio R15 = D15 filter / D15 protected soilSubballast over subgrade – Well to poorly graded, subrounded grainsAfter USBR (1963)122640–AREMA19 T1-2-4, p.1-2-25
Filter ratio R50 = D50 filter / D50 protected soilSubballast over subgrade – Well to poorly graded, angular particlesAfter USBR (1963)919.530–AREMA19 T1-2-4, p.1-2-25
Filter ratio R15 = D15 filter / D15 protected soilSubballast over subgrade – Well to poorly graded, angular particlesAfter USBR (1963)61218–AREMA19 T1-2-4, p.1-2-25
Open this set in the database ↗
Track curve geometry (Class I railroad superelevation and spirals) (5 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
Track curve geometryMaximum design superelevation5inRRSUPER text, p.1–3
Track curve geometryMinimum superelevation0.5inRRSUPER text, p.1–3
Track curve geometryMaximum superelevation runoff rate (freight torsion)62ft per inRRSUPER text, p.1–3
Track curve geometryMinimum tangent between spirals of reverse curves100ftRRSUPER text, p.1–3
Track curve geometryMaximum reduction of passenger-comfort spiral length25%RRSUPER text, p.1–3
Open this set in the database ↗
Track structure minimums and design track modulus (UFC 4-860-01) (17 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
Suggested design track modulusMain trackDesign wheel load 20–25 kips1,500lb/in./in.UFC486001 T5-7, p.45
Suggested design track modulusAuxiliary trackDesign wheel load 20–25 kips1,200lb/in./in.UFC486001 T5-7, p.45
Suggested design track modulusMain trackDesign wheel load 25–30 kips1,800lb/in./in.UFC486001 T5-7, p.45
Suggested design track modulusAuxiliary trackDesign wheel load 25–30 kips1,300lb/in./in.UFC486001 T5-7, p.45
Suggested design track modulusMain trackDesign wheel load 30–35 kips2,000lb/in./in.UFC486001 T5-7, p.45
Suggested design track modulusAuxiliary trackDesign wheel load 30–35 kips1,500lb/in./in.UFC486001 T5-7, p.45
Suggested design track modulusMain trackDesign wheel load 35–40 kips2,300lb/in./in.UFC486001 T5-7, p.45
Suggested design track modulusAuxiliary trackDesign wheel load 35–40 kips1,700lb/in./in.UFC486001 T5-7, p.45
Suggested design track modulusMain trackDesign wheel load 40–45 kips2,600lb/in./in.UFC486001 T5-7, p.45
Suggested design track modulusAuxiliary trackDesign wheel load 40–45 kips2,000lb/in./in.UFC486001 T5-7, p.45
Suggested design track modulusMain trackDesign wheel load 45–50 kips2,900lb/in./in.UFC486001 T5-7, p.45
Suggested design track modulusAuxiliary trackDesign wheel load 45–50 kips2,200lb/in./in.UFC486001 T5-7, p.45
Suggested limit on ballast surface stress pm = qo/AbUFC 4-860-01 track structure65psiUFC486001 text, p.48
Minimum ballast depth below wood or composite tiesUFC 4-860-01 track structure8inUFC486001 text, p.59
Minimum shoulder ballast widthUFC 4-860-01 track structure6inUFC486001 text, p.59
Subgrade fines content requiring subballastUFC 4-860-01 track structure85% silt and clayUFC486001 text, p.60
Frost check factor on frost penetrationUFC 4-860-01 track structure0.6×UFC486001 text, p.52
Open this set in the database ↗
Track stiffness and subgrade plastic strain parameters (14 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
Vertical track support stiffness for dynamic modelsRail–tie connection (pad)Per support2851,7105,700kip/inLI16 T2.3, p.51
Vertical track support stiffness for dynamic modelsTie–foundation connection (ballast)Per support1145702,850kip/inLI16 T2.3, p.51
Cumulative plastic strain coefficient aFat clayCHLi & Selig (1996) model0.821.21.5–LI16 T4.7, p.174
Cumulative plastic strain exponent bFat clayCHLi & Selig (1996) model0.120.180.27–LI16 T4.7, p.174
Cumulative plastic strain exponent mFat clayCHLi & Selig (1996) model1.32.43.9–LI16 T4.7, p.174
Cumulative plastic strain coefficient aLean clayCLLi & Selig (1996) model0.31.13.5–LI16 T4.7, p.174
Cumulative plastic strain exponent bLean clayCLLi & Selig (1996) model0.080.160.34–LI16 T4.7, p.174
Cumulative plastic strain exponent mLean clayCLLi & Selig (1996) model122.6–LI16 T4.7, p.174
Cumulative plastic strain coefficient aElastic siltMHLi & Selig (1996) model0.84–LI16 T4.7, p.174
Cumulative plastic strain exponent bElastic siltMHLi & Selig (1996) model0.080.130.19–LI16 T4.7, p.174
Cumulative plastic strain exponent mElastic siltMHLi & Selig (1996) model1.324.2–LI16 T4.7, p.174
Cumulative plastic strain coefficient aSiltMLLi & Selig (1996) model0.64–LI16 T4.7, p.174
Cumulative plastic strain exponent bSiltMLLi & Selig (1996) model0.060.10.17–LI16 T4.7, p.174
Cumulative plastic strain exponent mSiltMLLi & Selig (1996) model1.41.72–LI16 T4.7, p.174
Open this set in the database ↗
References (13)
  1. AREMA19 – AREMA (2019). Manual for Railway Engineering, Chapter 1 – Roadway and Ballast. American Railway Engineering and Maintenance-of-Way Association.
  2. CB – Carter, M. & Bentley, S.P. (2016). Soil Properties and their Correlations, 2nd ed. Wiley.
  3. RRSUPER – A Class I railroad (2002). RM 1305-0, Method for Determining Superelevation, Spiral Length, and Maximum Train Speed on Curves (December 2002).
  4. RRPIPE1 – A Class I railroad (2018). Specifications for the Design and Construction of Pipeline Occupancies (revised June 5, 2018).
  5. IDOT – Illinois DOT (2015). Geotechnical Manual.
  6. LI16 – Li, D., Hyslip, J., Sussmann, T. & Chrismer, S. (2016). Railway Geotechnics. CRC Press / Taylor & Francis.
  7. LOOK – Look, B.G. (2007). Handbook of Geotechnical Investigation and Design Tables. Taylor & Francis.
  8. MATC – Parsons, R., Han, J. et al. (2014). Permeability, Resistivity and Strength of Fouled Railroad Ballast. Mid-America Transportation Center Report MATC-UK:148, University of Kansas.
  9. PARSONS15 – Parsons, R.L., Han, J. et al. (2015). Mechanical and Hydraulic Properties of Recycled Railroad Ballast. Mid-America Transportation Center Report MATC-KU 465, University of Kansas.
  10. ROB – Robertson, P.K. & Cabal, K.L. (2010). Guide to Cone Penetration Testing for Geotechnical Engineering, 4th ed. Gregg Drilling & Testing.
  11. SELIG – Selig, E.T. & Waters, J.M. (1994). Track Geotechnology and Substructure Management. Thomas Telford.
  12. UFC486001 – U.S. Department of Defense (2022). UFC 4-860-01, Railroad Design and Rehabilitation, 23 June 2022.
  13. RRSHORE – Two Class I railroads (2004). Guidelines for Temporary Shoring (published October 25, 2004).
Correlations (9)
EstimateCorrelationLimits / notesSource
Fouling indexFI = P4 + P200 (percent passing No. 4 and No. 200 sieves)Selig & Waters (1994); categories clean < 1 … highly fouled > 40LI16 Eq. 3.1, p.84
Spoornet fouling indexFI(Spoornet) = 0.4 P19 + 0.3 P6.7 + 0.2 P1.18 + 0.1 P0.15 (percent passing 19, 6.7, 1.18, 0.15 mm)Intervention at about 80LI16 Eq. 3.2, p.86
Cumulative plastic strain of subgradeεp(%) = a (σd/σs)^m N^bσd = deviator stress, σs = soil compressive strength, N = load cycles; a, b, m by soil type in the databaseLI16 4.7, p.174
E80 lateral pressure on shoring (Boussinesq strip)σh = (2q/π)(β − sin β cos 2α); q = 80,000/(5 × tie length) psfβ and α are angles to the edges of the tie strip; q = 1778 psf for 9-ft tiesRRSHORE App. A, p.A-1
E80 impact factor for buried structuresIF = 1.75 for cover ≤ 5 ft; IF = 1.75 − 0.03 (H − 5) for 5–30 ft; IF = 1.0 below 30 ftH = height of cover (ft)RRPIPE1 3.2.3, p.13
Subballast filter (piping subgrade)D15(subballast) < 5 × D85(subgrade); P200(subballast) ≤ 5%Plus R50 and R15 ratios by filter character (database)AREMA19 1-2-4, p.1-2-25
Curve superelevationE = 0.0007 D S² − Eu (E, Eu in in.; D = degree of curve; S = speed, mph)Eu = unbalance; Eu = 0 is balancedRRSUPER Eq. 1, p.1
Minimum spiral lengthL = max(1.63 Eu Sp, 62 E) (ft)Passenger comfort and freight torsion; Sp = max passenger speed (mph)RRSUPER Eq. 2–3, p.2
Ballast surface stresspm = qo / Ab ≤ 65 psiqo = maximum rail seat load (lb); Ab = 270 in.² for 6×8 ties, 312 in.² for 7×9 tiesUFC486001 Eq. 5-11, p.48
All correlations ↗

Full database  ·  Laboratory tests  ·  Download Excel  ·  Library documents for this chapter  ·  Calculators for this chapter

Track Substructure Practice — failure mechanisms, fouling, maintenance and work near the track, summarized from the reference library railroad, geohazard and manual folders

1. Track subgrade problems: cause, type and what you see
CauseProblemContributing factorsWhat you see
Dead loadMassive shear failureWeight of train, track and fill; inadequate soil strengthHigh fills and cuts; often triggered by a rise in water content
Dead loadConsolidation settlementEmbankment weight on saturated fine-grained soilSettlement under higher static stress than before construction
Live loadSubgrade attritionBallast grinding a hard, clay-rich subgrade with water; no subballastMuddy ballast
Live loadCyclic mobility / liquefactionRepeated loading of saturated silt or fine sand (can occur in subballast)Large displacement, worse with vibration
Live loadProgressive shear failureRepeated overstressing of wet fine-grained soilSqueezing near the subgrade surface, heave in cribs or shoulder, depressions under ties
Live loadCumulative plastic deformationRepeated loading of soft or loose soilDifferential settlement, ballast pockets
EnvironmentFrost heave and thaw softeningFreezing with free water in frost-susceptible soilRough track in winter and spring
EnvironmentSwelling and shrinkageHighly plastic soil with changing moistureRough track surface
EnvironmentSlope erosionSurface and subsurface water, windSoil washed or blown away
EnvironmentSoil collapseWetting of loose depositsGround settlement

Source: LI16 Table 3.9, p. 113.

2. Ballast fouling: where it comes from and how to measure it
  • On average about 76% of fouling is ballast breakdown, 13% infiltration from the granular layer below, 7% from the surface, 3% from the subgrade and 1% tie wear – so clay pumping is the exception, not the rule (Selig & Waters Fig. 8.33)
  • Fouling index FI = P4 + P200: clean < 1, moderately clean 1–10, moderately fouled 10–20, fouled 20–40, highly fouled > 40 (AREMA Table 1-2-3; ballast limits and gradations unchanged in the 2025 edition)
  • The railroad's single ¾-in. field sieve: 25–40% passing is moderately fouled, 40–50% fouled, over 50% highly fouled; A Class I railroad intervenes at 40% (Li et al. Tables 3.4–3.5)
  • Drainage collapses as fouling rises: about 2.5–5 cm/s clean, below 0.0005 cm/s highly fouled (Li et al. Table 6.2)
  • Resistivity and friction angle both fall with fouling – clay fouling at 50% dropped φ from 53° to about 30° in large direct shear (MATC report Tables 6.2.4, 6.5.1)
  • GPR reads fouling and moisture because wet, fine material has a much higher dielectric constant than clean ballast (Li et al. Table 8.5)

Fouling values in the database ↗

Source: SELIG p. 8.25; AREMA19 p. 1-2-15; LI16 pp. 84–86, 279, 371; MATC pp. 48–88.

3. Drainage-related softening

Much subgrade failure is softening caused by water held in the upper track foundation, from drainage that is missing, blocked or poorly maintained. A fault-chart approach traces a track defect back through its causes (fouled ballast, ponding, blocked ditches or culverts) so drainage maintenance can be targeted where it prevents the most failures.

Source: USMAN pp. 547–555 (abstract and approach).

4. Embankment and subgrade maintenance – what not to do
  • Do not let water pond against an embankment – add culverts or improve surface drainage
  • Do not over-deepen side (cess) drains close to the track, or undercut the toe of an embankment
  • Do not let debris collect in or upstream of culverts, or let culvert outlets discharge onto the embankment slope
  • Do not steepen embankments or dump soil and rock on the slopes to widen them
  • Do not raise an embankment without internal drainage and without widening its base
  • Do not push material back into a blow-out – fix the drainage first and use free-draining, compactable fill
  • Do not build toe buttresses or widen fills with large rock – bigger is not always better
  • Get professional design for retaining structures, tunnel drainage and any riprap or fill in a stream

Source: CANTRELL §8.2.

5. Work next to the track
  • Temporary shoring (a Class I railroad): no excavation within 12 ft of track centerline; shoring movement ≤ 3/8 in. (12–18 ft) or 1/2 in. (18–24 ft) and rail movement ≤ 1/4 in.; E80 lateral pressure by Boussinesq strip with q = 1778 psf; embedment FS 1.3, anchored walls 1.5 × calculated embedment; backfill 95% modified Proctor
  • Buried structures: Cooper E80 with impact – 3,800 psf at 2 ft of cover to 150 psf at 30 ft (Class I railroad Table 1)
  • Pipelines: cased pipe at least 5.5 ft below base of rail; uncased gas 10 ft; longitudinal lines 4–6 ft of cover within 50 ft of track
  • Culverts: E80 and 100-year storm, HW/D ≤ 1.5, at least 36 in. diameter, open cut only where fill ≤ 10 ft; no concrete pipe under company tracks without approval
  • Railroad walls are typically soldier piles with lagging; design them for E80 surcharge and the deflection limits above

Loading, crossing and clearance values ↗

Source: RRSHORE §6–9 and App. A; RRPIPE1 §2.3, §3.2.3; RRPIPE2; RRCULV.

6. Investigation requirements from the railroads
  • Class I public projects: a series of three borings about every quarter mile (top of grade between ballast edge and shoulder, midslope, and ditch at the toe); in cuts, a boring atop the cut to 5 ft below the proposed ditch flowline; borings at each culvert extension; a soils engineer, not the driller, selects locations
  • Class I railroad bridges: borings to about twice the footing width or 10 ft below the estimated pile tip, preferably at the toe of the embankment, with a railroad representative present; report pile capacity vs depth, driving criteria and p-y springs
  • Class I railroad pipelines: borings on each side of the track for casings of 48 in. and larger, continuous sampling to 5 ft below invert, rock cored
  • Track alignment surveys: one boring every 500, 200 or 100 ft for high, medium or low subgrade strength; sample 10–15 ft below grade (Li et al. Table 8.1)

Source: RRGEO p. 1; RRBRG pp. 1–2; RRPIPE1 §3.1; LI16 p. 358.

7. Aerial geohazard and beaver dam inspection

The railroad's helicopter procedure runs GIS mapping with live GPS on a laptop, with a second screen for back-seat inspectors. Before the flight, build a base map with track and mileposts, the drainage network (1:20,000 or better), contours, access roads, culverts, bridges and crossings, flight hazards (towers and power lines), watershed outlines and known beaver dams. In flight, outline each watershed and give it a quick field rating, mark each beaver dam with a severity rating (a plus sign for active beavers), and add hazard points, lines and comments; the tables export to a spreadsheet for follow-up.

Beaver dam failure can release stored water and sediment and reshape the channel downstream, so dams upstream of culverts and bridges belong in the hazard inventory.

Source: BAHA pp. 1–15; WELSH abstract.

8. Water at the track: hydrology, scour and piping
  • Size culverts and ditches by the rational method for small basins (Q = C i A); railroad yard runoff coefficients are 0.20–0.40 (HDS-2 Table 5.7)
  • Railroads design culverts for 50–100-year storms, ditches for 5–10 years; most highways use 10–50 years (HDS-2 Table 1.1; Li et al. Table 6.3)
  • Flood risk is higher than the return period suggests: a 100-year culvert has about a 40% chance of seeing its design flood in 50 years, R = 1 − (1 − 1/Tr)^n (HDS-2 Table 4.25)
  • Rate channel stability at bridges and culverts with HEC-20's 13 weighted indicators: below 32 excellent, above 78 poor – a quick input to the hydraulic erosion hazard rating
  • Riprap: apply a stability factor of 1.0–1.2 in straight, uniform reaches, 1.3–1.6 at moderate bends and 1.6–2.0 at sharp bends, debris, ice or abutments (HEC-11 Table 1)
  • Piping under culverts and walls: check Lane's weighted creep ratio, from 2.5 for boulders to 8.5 for very fine sand or silt (UFC 3-220-05 Table 4-3)
  • Dewatering: get permeability from field pumping tests; table values and Hazen's k = C·D10² are first estimates only (UFC 3-220-05)
  • Flood and retaining walls: USACE sets overturning criteria as a minimum percentage of the base in compression and sliding criteria as minimum safety factors for each loading case, and requires checking cracks in cohesive foundations (EM 1110-2-2502 §4-9, §4-17, §4-18)

Hydrology and drainage values ↗

Source: HDS2 pp. 1-5, 4-90, 5-33; LI16 p. 282; HEC20 p. D.6; HEC11 p. 41; UFC pp. 3-6, 4-40; EM2502 Ch. 4.

9. Curve geometry and track work
  • A Class I railroad balances superelevation with E = 0.0007 D S² and caps design superelevation at 5 in.; the minimum is the larger of ½ in. or 2 in. below balanced for freight (3 in. passenger)
  • Superelevation must run off no faster than 1 in. per 62 ft; minimum spiral length is the larger of 1.63 Eu Sp and 62 E
  • Keep at least 100 ft of tangent between the spirals of reverse curves
  • GHRM note: subgrade repairs, undercutting and track raises on curves should restore the design superelevation and spirals – check these limits before returning track to service

Source: RRSUPER pp. 1–4.

10. Track structure minimums (UFC 4-860-01)
  • Ballast surface stress pm = qo/Ab should stay at or below 65 psi; use larger ties or closer spacing if not
  • Minimum ballast below wood or composite ties is 8 in. (6 in. over subballast); steel ties need 10 in. from the top of tie; main tracks usually need more
  • Shoulder ballast at least 6 in. wide, 12 in. for continuously welded rail
  • Subballast is required where the subgrade has 85% or more silt and clay, or LL > 50 and PI > 20
  • Frost check: 0.6 × frost penetration should not exceed the total ballast and subballast thickness
  • Design track modulus about 1,500–2,900 lb/in./in. for main track as wheel loads rise from 20 to 50 kips

Source: UFC486001 pp. 45–60.

References
  1. HDS2 – FHWA (2002). Highway Hydrology, Hydraulic Design Series No. 2, 2nd ed. FHWA-NHI-02-001 (superseded by HDS-2 Highway Hydrology 3rd ed., FHWA-HIF-24-007 (2024)).
  2. HEC20 – FHWA (2001). Hydraulic Engineering Circular No. 20, Stream Stability at Highway Structures, 3rd ed. FHWA NHI 01-002 (superseded by HEC-20 4th ed., FHWA-HIF-12-004 (2012)).
  3. HEC11 – FHWA. Hydraulic Engineering Circular No. 11, Design of Riprap Revetment (metric version).
  4. UFC – U.S. Department of Defense (2004). UFC 3-220-05, Dewatering and Groundwater Control (16 January 2004).
  5. EM2502 – U.S. Army Corps of Engineers (1989). EM 1110-2-2502, Retaining and Flood Walls (29 September 1989).
  6. RRSUPER – A Class I railroad (2002). RM 1305-0, Method for Determining Superelevation, Spiral Length, and Maximum Train Speed on Curves (December 2002).
  7. UFC486001 – U.S. Department of Defense (2022). UFC 4-860-01, Railroad Design and Rehabilitation, 23 June 2022.
  8. AREMA25 – AREMA (2025). Manual for Railway Engineering, Chapter 1 – Roadway and Ballast. American Railway Engineering and Maintenance-of-Way Association.
  9. LI16 – Li, D., Hyslip, J., Sussmann, T. & Chrismer, S. (2016). Railway Geotechnics. CRC Press / Taylor & Francis.
  10. SELIG – Selig, E.T. & Waters, J.M. (1994). Track Geotechnology and Substructure Management. Thomas Telford.
  11. AREMA19 – AREMA (2019). Manual for Railway Engineering, Chapter 1 – Roadway and Ballast. American Railway Engineering and Maintenance-of-Way Association.
  12. MATC – Parsons, R., Han, J. et al. (2014). Permeability, Resistivity and Strength of Fouled Railroad Ballast. Mid-America Transportation Center Report MATC-UK:148, University of Kansas.
  13. USMAN – Usman, K., Burrow, M. & Ghataora, G. (2015). Railway track subgrade failure mechanisms using a fault chart approach. Procedia Engineering 125, 547–555.
  14. CANTRELL – Cantrell Rail Services (2001). Manual on What to Do and What Not to Do When Performing Sub-grade Maintenance (prepared for Australian Rail Track Corporation).
  15. RRSHORE – Two Class I railroads (2004). Guidelines for Temporary Shoring (published October 25, 2004).
  16. RRGEO – A Class I railroad. Public Projects – Geotechnical Requirements.
  17. RRPIPE1 – A Class I railroad (2018). Specifications for the Design and Construction of Pipeline Occupancies (revised June 5, 2018).
  18. RRPIPE2 – A Class I railroad. Pipeline Crossing and Longitudinal Occupancy Specifications (form US-0510).
  19. RRCULV – A Class I railroad. Guidelines for Under Track Culverts.
  20. RRBRG – Ruel, M. (2003). General Requirements for Geotechnical Investigations for Bridge Construction Projects (a Class I railroad).
  21. BAHA – Ruel, M. (2008). MapInfo – BAHA Geo-hazard Inspection Instructions (Class I railroad helicopter geohazard and beaver dam inspection procedure).
  22. WELSH – Welsh, S.B. (2012). Geomorphic Changes Following Beaver Dam Failure and Abandonment. M.S. Plan B report, Utah State University.

All library documents for track substructure ↗

Further reading — ICE Manual of Geotechnical Engineering
The chapters below cover the same ground in more depth. They are cited, not reproduced; see Appendix G for the full cross-reference and edition notes.
2.3.0 Executive Summary

The track subgrade is the engineered foundation upon which the entire superstructure — rail, ties, ballast, and subballast — rests. Unlike highway or airfield pavement subgrades, railroad subgrades are subjected to high-frequency, high-magnitude cyclic loading from heavy-axle freight traffic (286,000 lb gross rail load is the North American standard), combined with dynamic amplification, repeated wetting and drying, freeze-thaw action, and the progressive accumulation of ballast fines over time. Subgrade failures — progressive shear failure, ballast pocket formation, pumping, differential frost heave — are among the most common and expensive maintenance problems faced by North American freight railroads.

This chapter provides the geotechnical consultant's framework for characterizing, designing, and remediating railroad track subgrades. It covers the Talbot load distribution method, stress at top of subgrade, ballast and subballast specification per AREMA Manual for Railway Engineering Chapter 1, blanket layer design, subgrade failure mode identification, track modulus, ballast fouling index, subgrade drainage, and ground-penetrating radar (GPR) as a diagnostic tool. Owner railroads set their own subgrade requirements; confirm them when the work is scoped.

Empirical Equations — Use and Limitations

The correlations used in this chapter are listed below. Each gives an estimate, not a test result. The full equation, variables, range of applicability, constraints and source for each one, and the note to record whenever one is used, are in the Empirical Equations & Correlations reference.

IDCorrelationGives
IS-18Shear-wave velocity from CPTVₛ
RK-10UCS from point load indexσ꜀
IX-13Small-strain shear modulus (Hardin)G_max
IS-07Undrained shear strength of clay from SPTSᵤ
IX-05Secondary compression ratioC_α
2.3.1 Background: The Railroad Track Structure

The railroad track structure transmits wheel loads through a layered system:

Rail → Tie (Crosstie) → Ballast → Subballast → Subgrade

The geotechnical consultant is primarily responsible for the subgrade and subballast layers, but must understand the full load path to correctly compute stress at the top of subgrade and specify appropriate materials.

2.3.1.1 Layer Functions
LayerMaterialPrimary Function
Rail115–141 RE steelCarry and distribute wheel load longitudinally
Tie (Crosstie)Concrete or timber, 8.5 ft longDistribute rail load to ballast; maintain gage
BallastCrushed stone (AREMA No. 4 or No. 24)Distribute tie load; drain; damp vibration; resist movement
SubballastGranular filter/transition materialDrainage; frost protection; separate ballast from subgrade
SubgradeNative or engineered fillUltimate load-bearing platform

AREMA MRE Chapter 1 governs ballast and subballast specification for owner railroads, with client-specific supplements as noted below.

The substructure, zone by zone

Selig and Waters divide the track at the tie–ballast interface. Rail, fastenings and ties make up the superstructure. Ballast, subballast and subgrade make up the substructure. The substructure gets less attention, but its properties vary far more and are harder to define, and it drives a large share of track maintenance cost.

Ballast zones. Describe and sample each zone separately:

  • Crib: between the ties.
  • Shoulder: beyond the tie ends.
  • Top ballast: the upper part, which tamping disturbs.
  • Bottom ballast: the lower part, which tamping does not reach. It is usually the most fouled.

“Boxing” is the cribs plus the upper shoulders. A clean crib tells you nothing about the bottom ballast.

What the subballast has to do. The book lists seven functions:

  • Reduce stress on the subgrade.
  • Insulate against frost.
  • Keep ballast and subgrade from mixing.
  • Stop subgrade fines from migrating upward.
  • Protect a hard subgrade surface from attrition by the ballast.
  • Shed surface water to the ditches.
  • Let water seeping up from the subgrade escape.

Functions 3 to 5 are the “blanket” functions. Expect track built without subballast to need high maintenance. Stabilized soil, asphalt and geosynthetics can stand in for some of these functions, but not all of them (Section 2.3.4; Chapter 7.2).

How deep the subgrade matters. Train-induced stress is significant to about 16 ft below the bottom of tie. Model studies show that rail deflection is still about half the surface value 80 in. down. The subgrade therefore controls much of the track’s resilience even where stress has dropped off. Set trackbed boring and CPT depths to match (Chapter 3.9).

Ballast gradation changes in service. Three things change it:

  • Mechanical breakdown from construction, tamping and traffic.
  • Weathering.
  • Fines moving in from the surface and from the layers below.

A specification for clean new ballast only covers its condition on day one.

After Selig & Waters (1994), chs. 1, 2 and 5. Full reference under Supplemental References.

Supplemental reference

Why substructure demands keep rising: heavy axle loads

The AAR Heavy Axle Load program (from 1988, with testing at FAST, Pueblo) led the industry to accept 286,000-lb gross-weight cars in interchange in 1991. By 2010, nearly all coal and about 30% of general freight moved in 286k cars (about 40% of all traffic), and net benefits were about $6 billion from 1994 to 2010. The earlier move to 100-ton (263k) cars in the 1970s had “caused havoc” with track that was adequate for 70-ton cars, and rail fatigue life on tangent track fell from about 580 MGT under mixed freight to 267 MGT under 100-ton unit trains. Phase II economic studies predicted that 286k operation would raise life-cycle costs for rail, ties, ballast and subgrade, turnouts and bridges, mainly through maintenance rather than capital cost:

Why Do Train Tracks Have Stones
Why Do Train Tracks Have Stones

Table 2-S1. Predicted cost relative to 263k operation (HAL Phase II, Hargrove et al., 1996)

West 286k (80 MGT)West 315kEast 286k (30 MGT)East 315k
Track maintenance111.3%132.7%122.6%147.5%
Track capital102.6%108.6%106.5%110.0%
Bridges112.7%156.9%114.0%137.7%
Operations90.4%93.8%91.1%95.3%
Total92.6%97.5%94%99.6%

Spot surfacing — the maintenance activity most tied to substructure performance — was among those most affected. On short lines, only about 55% of route-miles (63% for regionals) were open to 286k in 2011, and bridges were the main constraint. When a line is upgraded for heavier cars, the subgrade and ballast checks in this chapter should be repeated for the new axle load rather than carried over from the original design.

Source: Martland, C. D. (2013). “Introduction of Heavy Axle Loads by the North American Rail Industry.” Journal of the Transportation Research Forum 52(2): 103–125

How fast the load spreads: contact stress at each layer

Profillidis follows a 22-kip static wheel load down through the track. The contact area grows from about 0.2 in.² at the wheel–rail contact to about 1,550 in.² at the track bed–subgrade interface, and the stress falls from about 110,000 psi to about 6 psi — a reduction of 1,000 to 5,000 times. The calculation assumes the tie under the wheel carries 40% of the wheel load (finite-element and field results, see §2.2) and ignores dynamic effects.

Figure 2.3-11. Base area of each track component and the stress it carries under a 11-ton wheel load. Profillidis Fig. 7.3.
Figure 2.3-11. Base area of each track component and the stress it carries under a 11-ton wheel load. Profillidis Fig. 7.3.
Figure 2.3-44. Load reaching the subgrade over a much larger area, if the structure above is intact.
Figure 2.3-44. Load reaching the subgrade over a much larger area, if the structure above is intact.

He defines the subgrade as extending to about 6.5 ft below the top of subgrade, the depth to which train loading has a mechanical effect. That depth is a useful minimum for exploration and for the zone over which subgrade parameters are needed.

After Profillidis (2014), §7.2, Fig. 7.3. Full reference under Supplemental References.

Field view: typical ballast section and how load spreads

Table 2.3-18. Typical ballast layer dimensions (course guidance)
ParameterTypical value
Depth below ties12–18 in. (8 in. for yard and secondary track)
Shoulder width, tangent and inside of curves8–12 in.
Shoulder width, outside of curves12–18 in.
Shoulder slope2:1 to 3:1 (excess width or slope can block internal drainage)

Stress under passing trains is about 6,000 psf just below the ties and falls to about 200 psf at 5 ft depth, before any dynamic allowance. At the rail, a loaded tank car’s weight spreads over about 19 ft (roughly 11 ties), and it continues to spread through the ballast and subgrade. A thin or degraded ballast and sub-ballast section concentrates stress into a smaller area of subgrade than the design assumed. The course states that substructure condition is the leading cause of track-geometry degradation, and that the substructure is what fails about 80% of the time when track has a problem.

How to Design a Railway Track
How to Design a Railway Track
Figure 2.3-42. Axle-load distribution at the rail: a car’s weight spread over roughly 19 ft.
Figure 2.3-42. Axle-load distribution at the rail: a car’s weight spread over roughly 19 ft.
Figure 2.3-43. The same load spreading through the ballast.
Figure 2.3-43. The same load spreading through the ballast.

After Geotechnology for Railroaders Program, Module 3; §02–03, §13. Full reference under Supplemental References.

2.3.2 Load Distribution — Talbot Method

The Talbot (1920) equation estimates the vertical pressure at depth h below the tie from the average tie–ballast contact pressure p_a:

p_c = 16.8 p_a / h^1.25 (psi; h in inches below the tie base) [AREMA MRE Ch. 1, Part 2, Section 2.11.2.3]

For quick checks, this chapter also uses a simple load-spread approximation that treats the ballast and subballast as one bearing layer (Section 2.3.2.1). Section 2.3.2.3 applies the full Talbot method.

2.3.2.1 Stress at Top of Subgrade

The vertical stress at the top of subgrade beneath a single tie is estimated with a load-spread approximation:

σ_s = (P_d) / (A_eff) (psf)

where:

P_d = P_w × DLF (lb, dynamic wheel load)

A_eff = (B_t + 2 × d × tan θ) × (L_t + 2 × d × tan θ) (ft²)

  • P_w = static wheel load (lb); for Cooper E-80: P_w = 80,000 lb per axle = 40,000 lb per wheel (per AREMA Ch. 8)
  • DLF = dynamic load factor (1.2 to 1.5 by client; see Introduction)
  • B_t = tie base width ≈ 0.917 ft (11 in.) for concrete ties, 0.75 ft (9 in.) for timber
  • L_t = tie length = 8.5 ft
  • d = combined ballast + subballast thickness (ft)
  • θ = pressure distribution angle, assumed 35° in this chapter (not an AREMA value); tan(35°) = 0.700
Figure 2.3-12. Distribution of a wheel load over successive ties: 7%, 23%, 40%, 23%, 7%. Profillidis Fig. 8.10.
Figure 2.3-12. Distribution of a wheel load over successive ties: 7%, 23%, 40%, 23%, 7%. Profillidis Fig. 8.10.

For a single dynamic wheel load P_d = 40,000 × 1.3 = 52,000 lb, an 11-in. concrete tie and d = 2.0 ft (12 in. ballast + 12 in. subballast):

A_eff = (0.917 + 2 × 2.0 × 0.700) × (8.5 + 2 × 2.0 × 0.700)

= (0.917 + 2.80) × (8.5 + 2.80)

= 3.717 × 11.30 = 42.0 ft²

σ_s = 52,000 / 42.0 = 1,238 psf = 0.62 tsf

This is the design stress at the top of subgrade used for bearing capacity checks and to assess subgrade failure potential.

Which design variables actually move the stresses

Selig and Waters ran a multilayer model study (GEOTRACK, 32,900-lb wheel) to see which design choices change rail seat load, ballast pressure and subgrade stress most. Use it to decide where design effort pays.

Table 2-SW1. Sensitivity of track response to design variables (multilayer model)
ChangeEffect
Tie spacing 10 → 36 in.Rail seat load ×3; stress at ballast surface ×4; subgrade stress +50%
Rail moment of inertia 38.7 → 150 in.4Rail seat load −40%
Ballast depth 24 → 6 in.Subgrade stress more than doubles: the strongest lever on subgrade stress
Ballast modulus 100,000 → 8,000 psiBallast strain ×9
Tie stiffnessStiff ties act as rigid footings and push peak ballast pressure to the tie ends; flexible ties peak under the rail seat. Subgrade stress is similar either way.

Rail seat load is shared about 36% by the tie under the wheel, 22% by each adjacent tie and 10% by the next.

Quick hand checks.

  • Maximum rail seat load ≈ maximum rail support force per unit length × tie spacing.
  • Average pressure at the tie base ≈ 2 × rail seat load ÷ tie bearing area.

Measured values for comparison. At FAST, wheel loads of 14,000 to 32,900 lb gave the following:

  • Subgrade stress under concrete ties: 6.8–10.1 psi.
  • Subgrade stress under wood ties: 3.8–5.7 psi.
  • Resilient subgrade deflection: 0.025–0.033 in.

Ballast type (limestone, traprock or granite) had no detectable effect on the resilient response. These values are consistent with the roughly 10-psi subgrade stress in Table 2.3-1, which makes them a useful reasonableness check.

After Selig & Waters (1994), ch. 5. Full reference under Supplemental References.

Inputs for the equations in this section (9)
SymbolWhat it isComes fromHow to get itTypical range
σsintermediate value computed on this pageAnother equationComputed: σ_s = ( P_d ) / ( A_eff ) (psf)project-specific
Pdintermediate value computed on this pageAnother equationComputed: P_d = P_w × DLF (lb, dynamic wheel load)project-specific
Aeffintermediate value computed on this pageAnother equationComputed: A_eff = ( B_t + 2 × d × tan θ) × ( L_t + 2 × d × tan θ) (ft²)project-specific
Pwstatic wheel load (lb)Loading criteriaFrom the loading criteria: AREMA MRE (Cooper E-80, impact), structural loads from the designer, or equipment specifications.project-specific
DLFdynamic load factor (1.2 to 1.5 by clientChart, table or correction factorRead from the cited chart or table for the site conditions; values listed in the definition.project-specific
Bttie width = 0.667 ft (8 in.) for concrete ties, 0.583 ft (7 in.) for timberProject geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific
Lttie length = 8.5 ftProject geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific
dcombined ballast + subballast thickness (ft)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific
θpressure distribution angle = 35° (AREMA ChChart, table or correction factorRead from the cited chart or table for the site conditions; values listed in the definition.project-specific
2.3.2.2 Stress at Subgrade — Simplified Table
Table 2.3-1. Approximate σ_s at Top of Subgrade by the load-spread method of Section 2.3.2.1 (Cooper E-80 wheel, DLF = 1.3, 11-in. concrete tie, θ = 35°)
Ballast + Subballast Thickness (in.)σ_s (psf)σ_s (tsf)
181,6260.81
241,2380.62
309810.49
368000.40
426670.33
485660.28

Subgrade bearing capacity is checked against σ_s. For soft fine-grained subgrades (CBR < 4), ballast and subballast thickness ≥ 36 in. is typically required to reduce stress to manageable levels.

AREMA subgrade-pressure equations and allowable pressure by soil type

AREMA allows several equations for stress at the top of subgrade:

  • Talbot: Pc = 16.8 Pm / h1.25 (h in inches). It is empirical and was calibrated on lighter loads.
  • Japanese National Railways: Pc = 50 Pm / (10 + h1.35) (h in cm).
  • Boussinesq.
  • Love’s circular-area solution.

Here Pm = 2 × rail seat load × impact factor ÷ effective tie bearing area. The effective area and the limit on Pm depend on tie type:

  • Wood ties: about two-thirds of the tie bearing area; Pm ≤ 65 psi.
  • Concrete ties: the full bearing area; Pm ≤ 85 psi.

The traditional universal subgrade limit of 20 psi is too high for soft soils and too conservative for strong ones. Table 2-SW2 gives soil-specific values.

Table 2-SW2. Allowable subgrade pressure by soil type (0.6 × NAVFAC static allowable)
Subgradepsi
Compact till or hardpan65–100
Gravel, very compact / loose55–85 / 25–50
Coarse-to-medium sand, very compact / loose30–50 / 15–25
Fine sand, loose8–15
Clay, very stiff to hard25–50
Clay, medium to stiff8–25
Clay, soft4–8
Silt, very stiff / soft15–30 / 4–8

These values come from static bearing practice and may still be unconservative under millions of load repetitions. For soft or wet fine-grained subgrade, check the granular depth with the threshold-stress approach in Section 2.3.4.2.

After Selig & Waters (1994), ch. 10. Full reference under Supplemental References.

Load sharing between ties, dynamic increment and subgrade stress (finite-element results)

The classical assumption is that the tie under a wheel carries 50% of the wheel load and each neighbor 25%. Stress measurements and finite-element analysis give a different split: 40% on the tie under the load, 23% on each adjacent tie and 7% on each second tie, with negligible effect beyond.

Track and wheel defects add a dynamic load, so analysis should use Qtot = Qstat + Qdyn, where Qdyn can reach 50% of the static wheel load. For a 11-ton wheel at 124 mph the measured increment was 4.4–6.6 tons. The book separates three frequency bands: 0.5–15 Hz (sprung mass, rolling-stock dependent), 20–100 Hz (unsprung mass, governed by track quality and stiffness) and 100–2,000 Hz (rail corrugation). Empirical dynamic impact factors close to measured values range from 1.35 to 1.6 at 125 mph, and 1.5 is suggested near that speed. Compare these with the AREMA impact allowance used in this section, which remains the design basis.

Figure 2.3-13. Track defect producing an additional dynamic load Qdyn on top of the static load Qstat. Profillidis Fig. 8.14.
Figure 2.3-13. Track defect producing an additional dynamic load Qdyn on top of the static load Qstat. Profillidis Fig. 8.14.
Figure 2.3-15. Dynamic impact factor η vs. speed according to various theories and measurements. Profillidis Fig. 8.15.
Figure 2.3-15. Dynamic impact factor η vs. speed according to various theories and measurements. Profillidis Fig. 8.15.

Elastoplastic finite-element runs (Figure 2.3-14) show that stress at the top of subgrade depends mainly on subgrade quality and only secondarily on track-bed thickness. With all else equal, moving the subgrade up one class (S1→S2, S2→S3, S3→rock) increases the stress developed in the subgrade by about 50%: a stiffer subgrade attracts more load, but carries it with far less settlement.

Figure 2.3-14. Vertical stress at the subgrade level vs. track-bed thickness e (ballast + subballast) for subgrade classes S1–S3 and rock, by tie type. Profillidis Fig. 8.7.
Figure 2.3-14. Vertical stress at the subgrade level vs. track-bed thickness e (ballast + subballast) for subgrade classes S1–S3 and rock, by tie type. Profillidis Fig. 8.7.

After Profillidis (2014), §7.11.2, §8.4.7–8.4.8, §8.6–8.7, Figs. 8.7, 8.10, 8.14, 8.15. Full reference under Supplemental References.

How the track spreads a wheel load, and why no component can be designed alone

The track is a load-spreading system. It takes a concentrated wheel load at the rail head and spreads it along the track, across it and down through the section until the subgrade can carry it. Track that is well designed, built and maintained shares the load evenly, so each component carries its part. The designer’s job, on new track or on an upgrade of existing track, is to select a section that carries the design wheel load without overstressing any of the four main components: rail, ties, ballast and subgrade.

Along the track. When a wheel sits directly over a tie, that tie carries less than half of the wheel load. The rest goes to the two ties on each side (Figure 2-S5). For a 30,000-lb wheel on good track the UFC example split is 40% / 20% / 10%. That is close to the 40 / 23 / 7 finite-element split given above.

Example load sharing along the track: a 30,000-lb wheel centered over tie 3. UFC 4-860-01FA Fig. 3.1-10.
Figure 2-S5. Example load sharing along the track: a 30,000-lb wheel centered over tie 3. UFC 4-860-01FA Fig. 3.1-10.

Down through the section. Pressure at the wheel–rail contact, about 60,000 psi over roughly ½ sq in., falls to about 300 psi on the tie plate, about 40 psi at the base of the tie and about 10 psi (1,440 psf) at the top of subgrade (Figure 2-S6). That is the same order as the Table 2.3-1 values for 18 to 24 in. of ballast and subballast, so it is a quick reasonableness check on a Talbot calculation. Actual pressures vary with wheel load, track section and track condition.

Track Design Calculations
Track Design Calculations
Example vertical pressure reduction from rail head to subgrade under a 30,000-lb wheel. UFC 4-860-01FA Fig. 3.1-11.
Figure 2-S6. Example vertical pressure reduction from rail head to subgrade under a 30,000-lb wheel. UFC 4-860-01FA Fig. 3.1-11.

Design point. Track is simple to build, but its behavior under load is not. Strengthening one component can increase the load on another. When a rehabilitation changes one component (rail section, tie type or spacing, ballast depth), recheck the others, including the stress at top of subgrade in Section 2.3.2.1.

After UFC 4-860-01FA (2004), ch. 6, §5, Figs. 3.1-10 and 3.1-11. Comparison with Section 2.3.2 and Table 2.3-1 added by the authors. Full reference under Supplemental References.

Selecting the design wheel load from the car mix

Set the design wheel load from the heaviest loaded car that commonly runs over the track, not the rare heaviest movement. A locomotive usually puts down the heaviest single wheel. On most track, though, loaded-car wheels far outnumber locomotive wheels, so the car wheel load governs in most cases. Check both before the design is final.

The design wheel load is the static wheel load of that car plus an allowance for speed and for track and wheel irregularities. Table 2-S8 gives planning values for slow-speed track:

  • 10–25 mph: connecting track between the site and the serving railroad.
  • ≤ 10 mph: yard, industry-lead and terminal track.
  • Light use: track used mainly by a switch engine, for empty-car storage or only occasionally.
Table 2-S8. Planning design wheel loads by car type and track use (lb per wheel)
Most common heavy car10–25 mph≤ 10 mphLight use
Box, 40T20,00017,60016,000
Box, 50T26,25023,10021,000
Box, 70T34,37530,25027,500
Flat, 40T17,50015,40014,000
Flat, 50T23,75020,90019,000
Flat, 80T (6-axle)23,75020,90019,000
Flat, 100T (6-axle)32,50028,60026,000
Flat, 140T (6-axle)38,75034,10031,000
COFC, 70T30,00026,40024,000
COFC, double stack50,00044,00040,000
TOFC, 70T30,00026,40024,000
Gondola, 40T high side18,75016,50015,000
Gondola, 50T22,50019,80018,000
Tank, 7,500 gal16,25014,30013,000
Tank, 10,000 gal22,50019,80018,000
Tank, 20,000 gal36,25031,90029,000
Hopper, 50T21,25018,70017,000
Hopper, 70T30,00026,40024,000
Hopper, 100T (263K)41,12536,19032,900
Hopper, 120T (286K)44,75039,38035,800
Hopper, 125T (315K)49,25043,34039,400
Locomotive, EMD GP7 / GP937,50033,00030,000
Locomotive, EMD SW831,25027,50025,000
Locomotive, 80-ton industrial25,00022,00020,000
Locomotive, GE 65-ton20,00017,60016,000
Locomotive, GE 40-ton13,75012,10011,000

Authors' check: the Light use column equals the static wheel load (gross rail load ÷ 8 for a four-axle car; e.g., 286,000 ÷ 8 ≈ 35,800 lb). The ≤ 10 mph and 10–25 mph columns are the static value × 1.10 and × 1.25.

Limits on use. These speed allowances are lower than the 1.2 to 1.5 dynamic load factors used elsewhere in this manual because they assume slow operation. Use Table 2-S8 only for industrial, yard, terminal and light-density track. For mainline work, use Cooper E-80 or 286,000-lb loading with the client’s dynamic load factor (Chapter 1.0, §I.4).

After UFC 4-860-01FA (2004), ch. 2, §4, Table 1.4-2. Car and locomotive designations as given in the source; factor check added by the authors. Full reference under Supplemental References.

Dynamic loads, rare heavy impacts and the fourth-power rule

How large the dynamic load is depends on the traffic. North American static wheel loads range from about 12,000 lb (light rail) to 39,000 lb (heavy haul). Measured dynamic loads compare as follows:

  • FAST heavy-haul unit trains with good wheels: dynamic loads were close to static.
  • High-speed passenger corridor mixed traffic: dynamic loads ran well above static at the 2% exceedance level. Almost all of the excess came from passenger cars (23,000-lb static wheels) with wheel flats at 80–110 mph.
  • Continuous welded rail with good maintenance: dynamic loads typically run 10–20% above static.
  • Wheel and rail defects: loads near 3× static, with vibration above 100 Hz.

Rare heavy loads can control settlement. In box tests the order of loading did not change the final settlement. Once the largest load had been applied, smaller loads added almost nothing. A small share of heavy impacts, even 1 in 1,000, can therefore govern ballast settlement. Removing wheel flats, battered joints and rail defects is a substructure measure as well as a rail measure.

Uplift. The rail lifts the tie ahead of the wheel and then drives it back down. Where water is present, this pumps it.

Axle load and maintenance cost. German (DB) experience puts ballast maintenance cost roughly in proportion to the fourth power of ballast pressure, and British Rail concurs. By that rule, a 20% increase in axle load (for example, 100-ton to 125-ton cars) about doubles ballast maintenance. In box tests, raising the wheel load from 36 to 50 kips doubled the fines produced and tripled coarse breakage. DB responded with these changes:

  • 24-in. tie spacing.
  • 8.5-ft ties.
  • 121 lb/yd rail.

Together they stretched tamping intervals from 1–2 years to 4–5 years. British Rail found lab settlement roughly proportional to axle load and to tie spacing. Going from 113 to 131 lb/yd rail cut settlement about 20%. Use these figures when a client asks what a heavier car fleet will cost in substructure maintenance (Chapter 1.1).

After Selig & Waters (1994), chs. 2, 6 and 8. Full reference under Supplemental References.

2.3.2.3 Ballast and Subgrade Stress Calculator (Talbot Method)

The stress that reaches the subgrade decides whether a track section will hold its surface. The classic railroad method combines three steps: the share of a wheel load carried by the tie under it, the average pressure between that tie and the ballast, and Talbot's empirical decay of pressure with depth through the granular layers. The library's notes on stresses from surface loads give the elastic (Boussinesq) solutions that Talbot's equation is compared with.

2.3.2.3.1 Method

Equation 2.3-1. Tie-ballast pressure

qr = P (1 + IF/100) DF;  pa = 2 qr / Ab;  IF = 33 V / (100 D) percent

where P is the static wheel load, DF the distribution factor for the tie spacing, Ab the tie bearing area, V speed in mph and D the wheel diameter in inches.

Equation 2.3-2. Talbot equation and required granular depth

pc = 16.8 pa / h1.25  (psi, inches);  h = (16.8 pa / pallow)0.8
Table 2.3-20. Typical inputs
ItemTypical valueNote
Wheel load35.75 kips (286k car); 39.4 kips (315k car)Gross weight / 8 wheels
Distribution factorAbout 0.45 to 0.60Increases with tie spacing
Impact, roadbed method33V/(100D): 55% at 60 mph on 36-in. wheelsTie bending design uses larger factors
Allowable tie-ballast pressureAbout 85 psi (timber ties)Confirm against the governing standard
Allowable subgrade pressureAbout 20 psi for competent subgradeLower for soft or wet subgrade

2.3.2.3.2 Worked example: heavy-axle traffic

Table 2.3-21. 315,000-lb car at 60 mph, 9 in. × 102 in. ties (calculator output)
ResultValue
Rail-seat load qr30.54 kips
Tie-ballast pressure pa66.5 psi
Subgrade pressure under 24 in. of ballast and subballast21.0 psi
Granular depth for 20 psi25.0 in.

Twenty-four inches of granular material leaves the subgrade just over the 20-psi target under 315,000-lb cars at 60 mph, consistent with the common practice of 12 in. of ballast over 12 in. of subballast for heavy-haul main track on a competent subgrade. A weak subgrade needs either more depth or improvement (Chapter 7.2). The calculator also shows a Boussinesq curve under a single tie; it falls below Talbot because it ignores the overlap from adjacent ties.

Open the track substructure stress calculator →
Rail-seat load, tie-ballast pressure, Talbot stress at depth, required ballast plus subballast depth, and a Boussinesq comparison.

Example 2.3-6: Talbot Stress Under Heavy-Axle Cars

Table 2.3-21 gives calculator output for 315,000-lb cars at 60 mph. Worked by hand, the three steps of the Talbot method are: the share of the wheel load carried by one tie, the pressure under that tie, and the decay of pressure with depth.

Competent subgrade, pallow = 20 psiBallast + subballastD = 36 in., V = 60 mphP = 39.4 kipsh = 24 in.Ab = 9 × 102 in., DF = 0.50Rail-seat load, pa = ?p at 24 in. = ? h for 20 psi = ?GivenStatic wheel 39.4 kips (315,000-lb car)V = 60 mph; D = 36 in.DF = 0.50; tie 9 × 102 in.h = 24 in.; pallow = 20 psiRequiredRail-seat load, tie-ballast pressureSubgrade pressure at 24 in.Depth h for 20 psiBlack = given; red = required
Given and required for Example 2.3-6.

Given

VariableValueDescription
P39.4 kipsStatic wheel load: 315,000 lb / 8 wheels
V60 mphSpeed
D36 in.Wheel diameter
DF0.50Distribution factor used by the calculator for the tie spacing
Ab9 in. × 102 in. = 918 in.²Tie bearing area
h24 in.Ballast plus subballast depth
pallow20 psiAllowable subgrade pressure, competent subgrade

Required

  • Rail-seat load and tie-ballast pressure
  • Subgrade pressure under 24 in.
  • Granular depth for 20 psi

Equations

  1. Eq. 1: IF = 33V / (100D) — impact factor, as a fraction
  2. Eq. 2 (Equation 2.3-1): qr = P(1 + IF) DF; pa = 2qr / Ab — rail-seat load and tie-ballast pressure
  3. Eq. 3 (Equation 2.3-2): pc = 16.8 pa / h1.25; h = (16.8 pa / pallow)0.8 — Talbot, psi and inches

Steps

Step 1 · Impact factor (Eq. 1)
33 × 60 / (100 × 36)
IF = 0.55 (55%)
↓
Step 2 · Rail-seat load (Eq. 2)
39.4 × 1.55 × 0.50
qr = 30.5 kips
↓
Step 3 · Tie-ballast pressure (Eq. 2)
2 × 30,540 / 918
pa = 66.5 psi
Spot check: Below the 85-psi allowable for timber ties (Table 2.3-20).
↓
Step 4 · Subgrade pressure at 24 in. (Eq. 3)
241.25 = 53.1; 16.8 × 66.5 / 53.1
pc = 21.0 psi
↓
Step 5 · Depth for 20 psi (Eq. 3)
(16.8 × 66.5 / 20)0.8 = 55.90.8
h = 25.0 in.
Spot check: ln 55.9 = 4.02; 0.8 × 4.02 = 3.22; e3.22 = 25.0.
↓
Solution
pc = 21.0 psi at 24 in.; 25 in. needed for 20 psi.

Solution

Rail-seat load 30.5 kips, tie-ballast pressure 66.5 psi, subgrade pressure 21.0 psi under 24 in., and 25.0 in. of granular material for 20 psi.

The hand calculation reproduces the calculator. Twenty-four inches leaves the subgrade just over the target, which is consistent with the common heavy-haul section of 12 in. of ballast over 12 in. of subballast on a competent subgrade. A weaker subgrade with a lower allowable pressure needs more depth or improvement (Chapter 7.2).

2.3.2.3.3 Sources in the library

These documents are in the reference library. The method summaries above are paraphrased; equations are standard forms.

  • Stresses in Soil due to Surface Loads, Stresses in Soil and Stresses and Strains (course notes), Shear Stress folder.Find source ↗Library entry
  • Boussinesq and Westergaard Stresses (ENCE 361 lecture 9), Shear Stress folder.Find source ↗
  • Chapter 2.3 of this manual for ballast and subballast specifications.Find source ↗
2.3.3 Ballast Specification
2.3.3.1 AREMA Ballast Gradations

AREMA MRE Chapter 1, Table 1-2-2 defines the standard ballast gradations. Numbers 24, 25, 3, 4A and 4 are main-line gradations; Numbers 5 and 57 are yard gradations. Two of the main-line gradations:

Table 2.3-2. AREMA Ballast Gradations No. 4 and No. 24 (after AREMA MRE Ch. 1, Table 1-2-2)
Sieve SizeAREMA No. 4, 1½–¾ in. (% Passing)AREMA No. 24, 2½–¾ in. (% Passing)
3 in.—100
2½ in.—90–100
2 in.100—
1½ in.90–10025–60
1 in.20–55—
¾ in.0–150–10
½ in.—0–5
⅜ in.0–5—

AREMA No. 24 (2½–¾ in.) and No. 4A (2–¾ in.) are the coarser main-line gradations commonly used for heavy-axle freight. No. 4 (1½–¾ in.) is the smallest main-line gradation. Confirm the gradation against the owner railroad's specification.

2.3.3.2 Ballast Quality Requirements

Per AREMA Chapter 1, Part 2, Table 1-2-1 (Section 2.3.3):

  • Los Angeles abrasion (degradation): ≤ 25% to 40% by rock type (traprock 25%; quartzite, limestone and dolomitic limestone 30%; granite 35%; blast furnace slag 40%). Owner railroads often set tighter limits for main track.
  • Sodium sulfate soundness (5 cycles, ASTM C88): ≤ 5.0%
  • Flat and/or elongated particles (ASTM D4791): ≤ 5.0%
  • Material passing No. 200 sieve (ASTM C117): ≤ 1.0%
  • Clay lumps and friable particles (ASTM C142): ≤ 0.5%
  • Absorption (ASTM C127): ≤ 1.0% for granite, traprock and quartzite; 2.0% for limestones and steel furnace slag; 5.0% for blast furnace slag
  • Bulk specific gravity (ASTM C127): ≥ 2.60 for natural rock

These requirements vary by owner railroad. Confirm them against the owner railroad's current standards when the work is scoped, and record the edition used.

Screening a ballast source beyond LA Abrasion

Petrography first. A thin-section examination flags rock that will break down in track whatever the index tests say. Selig and Waters list these “fatal flaws” (after Watters et al.):

  • High content of soft minerals (clay, mica, chlorite).
  • Argillaceous sedimentary rock (mudstone, shale).
  • Mica-rich metamorphic rock (slate, phyllite, schist).
  • Igneous rock with altered feldspar.
  • Sulfide content above 2–3%; pyrite oxidizes to acid.
  • Poor consolidation, or porosity above 5%.
  • Vesicular volcanics.
  • Friable crystalline rock.
  • Closely spaced joints, bedding or foliation.
  • Smooth particle surfaces, or tabular or elongated particles.

Abrasion tests measure different things.

  • LA Abrasion measures toughness. Its fines are mostly coarser than the No. 200 sieve.
  • Mill Abrasion (wet, 10,000 revolutions) measures hardness. Over 90% of its fines pass the No. 200 sieve, which is closer to what track produces.
  • The railroad combines the two as the Abrasion Number, AN = LAA + 5 × MA. The railroad pairs AN with gradation to estimate ballast life in MGT.

In an AAR test on a Class I railroad at about 300 MGT per year, fouling (minus No. 4) grew 0.4–0.6% per year, and 75–90% of it came from ballast breakdown. Fouling correlated with AN.

Aggregate Testing
Aggregate Testing

Shape. AREA adopted the Corps definitions in 1986: flat means thickness ÷ width < 1/3, and elongated means length ÷ width > 3, with a limit of 5% by weight. Flaky, angular particles raise shear strength, but they also break more, accumulate more permanent strain and lower stiffness.

Gradation. In laboratory tests, uniform ballast (Cu 1.14) showed about twice the plastic strain and 4–5 times the degradation of a broader gradation (Cu 4.1). The broader grading is stronger and settles less. But it has less void space to store fines, it can segregate, and it is more susceptible to fouling. The railroad ranks coarse uniform gradations best for fouling life, then fine uniform, then broad. The book finds no basis for a single optimum size. Durability and room to store fines govern.

Other indicators. Higher specific gravity goes with durability. Low absorption goes with weathering resistance. Higher rodded unit weight goes with lateral stability. Where limestone or other soft stone sits in wet track, a wet attrition (Deval) test is worth requesting. British Rail limited it to 4%.

After Selig & Waters (1994), chs. 3, 7 and 8. Full reference under Supplemental References.

Supplemental reference

Additional ballast quality screens

Section 2.3.3.2 gives the AREMA limits. Li et al. (2016) add two screens that are worth requesting when qualifying a new quarry: the Mill Abrasion test (Selig & Waters, 1994), which wears the stone in water and is more sensitive than LA Abrasion to the soft, clay-bearing rocks that turn to mud in track, and petrographic analysis of the parent rock. The railroad's limits show how far a freeze–thaw railroad tightens the AREMA values:

Table 2-S2. AREMA vs. Class I railroad ballast limits (Li et al., 2016, Table 3.3)

TestProcedureAREMAClass I railroad
Los Angeles AbrasionASTM C53535% max.45% max. (paired with Mill Abrasion)
Mill AbrasionSelig & Waters (1994)–9% max.
AbsorptionASTM C1271.0% max.0.5% max.
Sulfate soundnessASTM C885.0% max.1.0% max. (mainline)
Los Angeles Abrasion Test for Aggregate
Los Angeles Abrasion Test for Aggregate

Table 2-S3. Rock properties that lead to poor ballast performance (after Watters et al., 1987)

Rock propertyDeterioration problem
Soft minerals (e.g., clay shale)Rapid wear and crushing
Minerals that weather or deteriorate rapidlyWeathering of the stone in track
Poorly consolidated textureRapid abrasion
High porosityFreeze–thaw deterioration
Smooth particle surfacePoor stability
Long, flat particle shapePoor stability; breakage of elongated pieces

Li et al. recommend petrographic analysis of the parent rock whenever a new source is being qualified, because it shows secondary minerals and textures that the index tests can miss.

Source: Li, D., Hyslip, J., Sussmann, T. and Chrismer, S. (2016). Railway Geotechnics. CRC Press / Taylor & Francis

European ballast categories (EN 13450) for comparison with AREMA

The European standard designates ballast by a pair of sieve sizes, 1¼ in. lower and 2 in. or 2½ in. upper, and lets the supplier declare a category for each property. The Los Angeles test is the reference hardness test (in the EN version: 22-lb sample, 1,000 revolutions at 31–33 rpm). Many older regulations simply require LA < 25.

Figure 2.3-17. Gradation of railway ballast by grading category, EN 13450 (1¼–2 in. and 1¼–2½ in.). Profillidis Table 12.2.
Figure 2.3-17. Gradation of railway ballast by grading category, EN 13450 (1¼–2 in. and 1¼–2½ in.). Profillidis Table 12.2.
Table 2.3-9. EN 13450 ballast categories by Los Angeles and Micro-Deval coefficient
Los Angeles coefficientCategoryMicro-Deval coefficientCategory
≤ 12LARB12≤ 5MDERB5
≤ 14LARB14≤ 7MDERB7
≤ 16LARB16≤ 11MDERB11
≤ 20LARB20≤ 15MDERB15
≤ 24LARB24> 15declared
> 24declared
Table 2.3-10. EN 13450 limits on fines, fine particles and flakiness
PropertyCategory limits
Fine particles (passing No. 35)A: 0.6%  ·  B: 1.0%  ·  declared > 1.0%
Fines (passing No. 230)A: 0.5%  ·  B: 1.0%  ·  C: 1.5%  ·  declared > 1.5%
Flakiness index≤ 15, ≤ 20, ≤ 35, declared > 35
Shape index≤ 10, ≤ 20, ≤ 30, 5–35, declared > 30
Particles ≥ 4 in. long (sample > 88 lb)A: 4%  ·  B: 6%  ·  C: 8%  ·  D: 12%

Deval requirements in older regulations range from a coefficient greater than 12 (limestone) or 14 (hard rock) to greater than 16, which may exclude limestone and push a railway toward granite. French practice requires the LA and Deval results to plot together inside an acceptance band (Figure 2.3-18).

Figure 2.3-16. Typical gradation of normal ballast with “excellent” and rejection limits, French regulations. Profillidis Fig. 12.1.
Figure 2.3-16. Typical gradation of normal ballast with “excellent” and rejection limits, French regulations. Profillidis Fig. 12.1.
Figure 2.3-18. Acceptable combination of Los Angeles and Deval coefficients, French regulations. Profillidis Fig. 12.5.
Figure 2.3-18. Acceptable combination of Los Angeles and Deval coefficients, French regulations. Profillidis Fig. 12.5.

After Profillidis (2014), §12.2–12.4, Tables 12.2–12.9, Figs. 12.1, 12.5; after EN 13450 (2002). Full reference under Supplemental References.

Ballast shoulder, crib fill and lateral track resistance

Lateral (transverse) track resistance has three parts: friction under the tie (proportional to tie weight), friction along the tie sides from crib ballast, and passive resistance at the tie ends from the shoulder. The crib component is about 40–50% of the total for timber ties, 30% for monoblock concrete and 15–25% for twin-block ties, so under-filled cribs cost timber track the most.

Figure 2.3-22. Lateral resistance by tie type (timber, steel, monoblock, twin-block). Profillidis Fig. 13.7.
Figure 2.3-22. Lateral resistance by tie type (timber, steel, monoblock, twin-block). Profillidis Fig. 13.7.
Figure 2.3-47. Exposed tie ends with no standard shoulder: a lateral-restraint deficiency.
Figure 2.3-47. Exposed tie ends with no standard shoulder: a lateral-restraint deficiency.
  • Widening the shoulder and heaping it above tie level gives more resistance than widening alone; the shoulder slope matters less (Figure 2.3-20).
  • Immediately after tamping, lateral resistance is about 50% of its stabilized value. It is almost fully recovered after about 2 million tons of traffic; dynamic stabilization and crib compaction shorten the recovery (Figure 2.3-21).
  • Fully stabilized twin-block concrete track resists more than twice as much as timber; monoblock concrete sits between. Lengthening ties from 8 ft to 8.5 ft (German practice) added 15–20%. Hard, smooth tropical-hardwood ties give about 15% less than other timber; grooving their seat adds 20–25%.
  • Closer tie spacing slightly lowers resistance per tie but raises it per unit length of track.
Figure 2.3-19. Tie end, ballast shoulder width c and shoulder heap height h. Profillidis Fig. 13.2.
Figure 2.3-19. Tie end, ballast shoulder width c and shoulder heap height h. Profillidis Fig. 13.2.
Figure 2.3-20. Lateral resistance vs. shoulder width c, with and without a heaped shoulder. Profillidis Fig. 13.3.
Figure 2.3-20. Lateral resistance vs. shoulder width c, with and without a heaped shoulder. Profillidis Fig. 13.3.
Figure 2.3-21. Recovery of lateral resistance after maintenance vs. traffic, with and without crib compaction. Profillidis Fig. 13.6.
Figure 2.3-21. Recovery of lateral resistance after maintenance vs. traffic, with and without crib compaction. Profillidis Fig. 13.6.

These numbers explain why slow orders follow surfacing and undercutting, and why shoulder width and crib fill should be checked wherever a ground-hazard repair has disturbed the ballast section.

After Profillidis (2014), §13.3–13.6, Figs. 13.2, 13.3, 13.6, 13.7. Full reference under Supplemental References.

The six functions of ballast and what good ballast requires

Ballast does six jobs: drainage, load distribution, vertical stiffness, longitudinal hold, lateral hold, and making surfacing practical. Failure of a function shows in the geometry: 2.5 in. or more of rail deflection at a joint means load distribution has failed, uneven support shows as cross-level, and ballast plowed in the direction of travel means it is too fine to hold the track. Judge ballast by digging, not by the surface.

Figure 2.3-46. Cross-level deviation, the visible symptom of uneven substructure support.
Figure 2.3-46. Cross-level deviation, the visible symptom of uneven substructure support.

Ballast shear strength comes from friction, which depends on size, angularity and interlocking. Prefer hard, dark, fine-grained extrusive rock (andesite, basalt, micro-diorite). Limestone, quartz, metamorphic rock and shale are unsuitable, and soft rock can grind into a mud spot within 2–3 years. Ballast life is roughly 200–900 MGT depending on rock type: some limestone lasts about 300 MGT, andesite about 900 MGT.

Figure 2.3-45. Angular, dark, extrusive rock: the preferred ballast material.
Figure 2.3-45. Angular, dark, extrusive rock: the preferred ballast material.

Shoulder width is a standard to enforce, not tolerate. A minimum 12-in. shoulder is what holds the ties laterally, and inadequate shoulders can contribute to derailments.

After Geotechnology for Railroaders Program, Module 3, Module 2; Module 3 §04–05, §11; after Selig & Waters (1994). Full reference under Supplemental References.

Project management · Seeley (1993)

Taking Off Ballast, Ties and Track: A Worked Example

Seeley’s chapter on measuring rail track (CESMM3 Class S) sets out conventions that carry over to North American work:

  • Supply and laying are separate items, because the owner often furnishes track materials. Track foundations (ballast) are the exception: one item covers both supplying and placing them.
  • Bottom ballast and top ballast are separate items. Bottom ballast is placed before the track is laid; top ballast is placed after.
  • No deduction for ties. The volume of top ballast is measured without deducting the space the ties occupy. The ballast rate includes boxing, trimming to line and level, and tamping.
  • Ties are counted as track length divided by tie spacing, plus one.
  • Track laying is measured along the centerline, including the length through turnouts and diamonds. Turnouts and diamonds are also enumerated by type, and curves are “extra over” items split at a radius of about 984 ft (roughly a 5.8° curve).
  • Lifting, packing and slewing existing track is enumerated, stating the track length, the maximum lift and the maximum slew.

His example is 492 ft of straight single track with ballast 10.33 ft wide, a 6-in. bottom ballast layer and about 5 in. of top ballast, timber ties at 29.5-in. centers, and 113 lb/yd rail.

Table 2-PM1. Table: Take-off for 492 ft of single track (after Seeley 1993, Example XVIII, converted to US units)

ItemCalculationQuantity
Bottom ballast492 × 10.33 × 0.49 ft92.7 CY
Top ballast (no deduction for ties)492 × 10.33 × 0.43 ft80.3 CY
Ties492 ft / 2.46 ft + 1201 each
Rail, supply only2 rails × 492 ft at 113 lb/yd18.5 tons
Track layingcenterline length492 ft
Example 2.3-4: Ballast and Tie Take-Off for Single Track

Seeley’s example, converted from metric, shows the measurement conventions in Section 2.4 applied to a short length of track. The take-off is the first step of any ballast or tie cost estimate (Chapter 3.7).

top ballast tt = 0.427 ftbottom ballast tb = 0.492 ftw = 10.34 ft (3.15 m)s = 2.46 ftL = 492.1 ft (150 m), planBottom and top ballast volumes = ? Ties = ?GivenSingle straight track L = 492.1 ftBallast width w = 10.34 ftBottom ballast 0.492 ftTop ballast 0.427 ftTie spacing 2.46 ftRequiredBottom and top ballast volumesNumber of tiesBlack = given; red = required
Given and required for Example 2.3-4.

Given

VariableValueDescription
L150 m = 492.1 ftLength of straight single track
w3.15 m = 10.34 ftBallast width
tb0.15 m = 0.492 ftBottom ballast thickness
tt0.13 m = 0.427 ftTop ballast thickness
s0.75 m = 2.46 ftTie spacing

Required

  • Bottom and top ballast volumes
  • Number of ties

Equations

  1. Eq. 1: V = L × w × t / 27 — ballast volume in cubic yards; no deduction for ties
  2. Eq. 2: N = L / s + 1 — number of ties

Steps

Step 1 · Bottom ballast (Eq. 1)
492.1 × 10.34 × 0.492 / 27
92.7 CY
↓
Step 2 · Top ballast (Eq. 1)
492.1 × 10.34 × 0.427 / 27
80.3 CY
Spot check: Metric check: 150 × 3.15 × 0.13 = 61.4 m³ = 80.3 CY.
↓
Step 3 · Ties (Eq. 2)
492 / 2.46 + 1
201 ties
↓
Solution
92.7 CY bottom ballast, 80.3 CY top ballast, 201 ties.

Solution

Bottom ballast 92.7 CY; top ballast 80.3 CY; 201 ties.

Rounded US dimensions (0.49 and 0.43 ft) give slightly different volumes; carry the unrounded conversions when checking a converted example. Top ballast is measured without deducting the ties, because the rate includes boxing and tamping around them.

For railroad work: when a geotechnical design calls for undercutting and new subballast and ballast, give the quantities in the same structure that the track contractor and the railroad’s material desk use. List separately:

  • subballast, as a compacted neat volume converted to tons
  • bottom ballast placed before the track panel goes down
  • top ballast placed after it
  • surfacing passes
  • track lift or slew, with its maximum value

State whether the ballast volume deducts the ties, and convert to tons with a unit weight measured for the actual quarry source. That way the engineer’s tonnage and the tonnage the railroad orders are computed on the same basis.

Source: Seeley, I. H. (1993). Civil Engineering Quantities, 5th ed. Basingstoke: The Macmillan Press, pp. 237–241. Summarized and paraphrased. Full reference under Supplemental References.

2.3.4 Subballast Requirements and Blanket Layer Design
2.3.4.1 Subballast Gradation

Subballast serves as a transition filter between ballast and subgrade, provides drainage, and distributes load. AREMA Chapter 1, Part 2, Section 2.11 designs subballast as a filter between ballast and subgrade (Table 1-2-4 in the 2019 edition) and notes that standard dense-graded aggregate and aggregate base gradations may meet it. A typical gradation is shown below; confirm it against the filter check and the project specification.

Table 2.3-3. Typical Subballast Gradation
Sieve% Passing
1½ in.100
¾ in.55–85
No. 430–60
No. 1020–50
No. 4010–25
No. 2000–7

Filter compatibility between subballast and subgrade must be verified using Terzaghi filter criteria:

D₁₅(subballast) / D₈₅(subgrade) < 5 (piping criterion)

D₁₅(subballast) / D₁₅(subgrade) > 5 (permeability criterion, for drainage)

Subballast material, filter and placement criteria

Material. Selig and Waters base North American subballast requirements on ASTM D1241 (withdrawn 2024):

  • The coarse fraction is durable, with LA Abrasion ≤ 50%. This is higher than the ballast limit because contact stresses are lower.
  • The fraction finer than No. 40 has LL ≤ 25 and PI ≤ 6.
  • No clay lumps or organic matter.

Under saturated repeated loading, crushed rock with no plastic fines performed best and natural rounded gravel performed worst.

Filter criteria. The subballast must satisfy these against the subgrade below and against the ballast above:

  • D15(filter) ≤ 5 × D85(soil): retention.
  • D50(filter) ≤ 25 × D50(soil): avoids gap grading.
  • D15(filter) ≥ 4–5 × D15(soil): drainage. Apply this only where water must drain up out of the subgrade. It can be disregarded on embankments or sand subgrade.

For medium- to high-plasticity clay with no silt or sand, D15 of the filter may be up to 0.016 in., provided Cu ≤ 20 to limit segregation. Confirm with a repeated-load filter test, because the criteria were developed for steady seepage.

Permeability balance. Subballast should be at least 10 times less permeable than the ballast, with a sloped surface, so that rain sheds sideways instead of soaking the subgrade. It still needs to be more permeable than the subgrade so upward seepage can escape. In frost areas, do not add fines to lower the permeability.

When one gradation will not work. A single layer between AREMA No. 4 ballast and a fine subgrade would have to span fine gravel to silt. In that case, use two layers. The upper, coarser layer is matched to the ballast. The lower layer is a blanketing sand matched to the subgrade (Table 2-SW3).

Table 2-SW3. British Rail blanketing sand gradation
Sieve% passing
½ in.100
No. 880–100
No. 1670–90
No. 3048–76
No. 5024–60
No. 1005–42
No. 2000–10

Frost. Where frost and water can reach the subballast, keep silt plus clay below about 5%.

Placement. Shape and compact the subgrade to drain before placing subballast. Then:

  • Place in loose lifts of 4–6 in. and roller-compact at suitable moisture.
  • Make each distinct layer at least 6 in. thick when compacted, to allow for construction variability.
Layered Aggregate Sample – Road Construction
Layered Aggregate Sample – Road Construction

After Selig & Waters (1994), ch. 9. Full reference under Supplemental References.

2.3.4.2 Blanket Layer (Engineered Fill Layer)

Where native subgrade is soft (CBR < 3) or frost-susceptible, a blanket layer of select granular material is required between the subgrade and subballast. This is often called a "capping layer" or "sub-base" in international railroad practice.

Minimum blanket thickness to reduce σ_s to acceptable level:

From Table 2.3-1, select d (ballast + subballast + blanket total) to achieve σ_s ≤ σ_allow(subgrade).

For soft clay subgrade with q_u = 1,200 psf (s_u = 600 psf), a bearing check with FS = 3.0 for cyclic loading gives:

σ_allow = (π + 2) × s_u / FS, with s_u = q_u / 2 and FS ≥ 3.0 for cyclic loading

σ_allow = 5.14 × 600 / 3.0 ≈ 1,028 psf

From Table 2.3-1, this requires d of about 29 in. (use 30 in., σ_s ≈ 981 psf), or supplemental ground improvement (see Chapter 7.2).

Granular layer depth: minimums and the threshold-stress method

Typical minimums. North American practice has used the following:

  • Ballast: 6–12 in..
  • Subballast: 4–12 in..
  • The AREA norm: 12 in. of ballast plus 6 in. of subballast, 18 in. in total.

These values set ballast depth for tamping, fines storage and filtering. They do not, by themselves, protect a weak subgrade. Size the combined ballast and subballast (the “granular layer”) separately, to prevent progressive shear and excessive cumulative plastic settlement.

Threshold stress. Repeated-load triaxial tests show a cyclic deviator stress that separates two behaviors:

  • Below it, plastic strain accumulates at a decreasing rate and the soil stabilizes.
  • Above it, plastic strain accumulates at an increasing rate and the soil runs away to failure.

The threshold rises roughly linearly with confining stress. British Rail sets the granular depth where the traffic-induced stress drops to the threshold stress. For example, a 35-kip axle on a subgrade with a 8.7-psi threshold needs about 24 in..

British Rail practice.

  • Take the threshold as about 50% of the unconfined or undrained triaxial strength, or estimate it from subgrade modulus, CBR or a soil description.
  • Raise the design axle load 15–30% for vehicle body roll.
  • Use greater depth for cohesive clays.
  • Refer very soft soils and peat to a specialist.

Field validation. Subgrade movement (in. per million axles) was rapid where the actual granular depth was less than the design depth and slow where it was greater. Deepening the ballast stabilized a previously unstable site.

This method complements the Li–Selig method above. Use the threshold check as a quick screen, and use Li–Selig where the design tonnage and cumulative deformation must be shown explicitly.

After Selig & Waters (1994), ch. 10. Full reference under Supplemental References.

Inputs for the equations in this section (1)
SymbolWhat it isComes fromHow to get itTypical range
σallowintermediate value computed on this pageAnother equationComputed: σ_allow = (π + 2) × s_u / FS, with s_u = q_u / 2 and FS ≥ 3.0 for cyclic loadingproject-specific
Supplemental reference

Choosing a granular layer thickness method

The Talbot equation in AREMA (h = (16.8 p a /p c ) 0.8 in inches, about 0.24 (p a /p c ) 0.8 in meters, with a universal allowable subgrade stress of 20 psi) dates from field tests in the 1910s–1920s. Li et al. note it ignores subgrade type, repeated loading and material quality, so it is unconservative on soft soils and overly conservative on good ones. They compare four methods:

Table 2-S7. Comparison of granular layer design methods (Li et al., 2016, Table 5.1)

FeatureAREMA equationsRaymondBritish RailLi–Selig
TrafficSingle wheelSingle wheelSingle wheelMultiple wheel loads and total tonnage
Subgrade propertyNoneSoil typeThreshold strengthResilient modulus and compressive strength
Ballast propertyNoneNoneNoneResilient modulus
Design criteria20 psi allowableAllowable stress by soil classProgressive shearProgressive shear and cumulative deformation
Stress modelEmpiricalHomogeneousHomogeneousMultilayer
Figure 2.3-24. Modulus of elasticity and CBR ranges for subgrade classes S0–S3. Profillidis Fig. 9.5.
Figure 2.3-24. Modulus of elasticity and CBR ranges for subgrade classes S0–S3. Profillidis Fig. 9.5.
Figure 2.3-49. Fine-fouled ballast at a rail joint.
Figure 2.3-49. Fine-fouled ballast at a rail joint.

For heavy-haul mainline work on soft subgrade, the Li–Selig method (which checks both progressive shear and cumulative plastic deformation over the design tonnage) is the most defensible of the four; the Talbot result can be shown alongside it for comparison with the owner railroad's standards.

Source: Li, D., Hyslip, J., Sussmann, T. and Chrismer, S. (2016). Railway Geotechnics. CRC Press / Taylor & Francis

UIC subgrade quality classes and the formation layer

UIC Code 719R classes the subgrade by its expected behavior: S3 good (low settlement, very good support), S2 medium, S1 poor (large settlement), and S0 very poor, plus R for sound rock, which later UIC editions fold into S3. The class follows from fines content, plasticity, Los Angeles value for rock, and whether hydrogeological conditions are good or bad.

Table 2.3-11. UIC classification of subgrade quality (after UIC 719R)
Soil or rock descriptionHydrogeological conditionsSubgrade class
Rock of very good quality–R
Well-graded soils with < 5% fines; hard rock with LA < 30–S3
Soils with 5–15% fines; sand with < 5% fines; moderately hard rock (30 < LA < 40)good / badS3 / S2
Soils with 15–40% fines; rock moderately susceptible to weathering; soft rock (LA > 40); silty sand and schist with PI > 7good / badS2 / S1
Rock very susceptible to weathering; soils with > 40% fines; slightly plastic silt–S1
Organic soils; soils with > 15% fines at high moisture; soluble soils (rock salt, gypsum); thixotropic soils (quick clay); mixed material / organic; contaminated ground–S0
Figure 2.3-23. Classification of subgrade quality as a function of geotechnical characteristics and hydrogeological conditions (original table). Profillidis Table 9.2, after UIC 719R.
Figure 2.3-23. Classification of subgrade quality as a function of geotechnical characteristics and hydrogeological conditions (original table). Profillidis Table 9.2, after UIC 719R.

Fines = particles smaller than 60 µm. Some railways place the mixed/organic soils in S1.

S0 soils settle heavily, are inhomogeneous, change with time and let ballast punch in. Avoid them in alignment where possible or replace them; where neither is possible, especially under high embankments, combine ground improvement with thicker ballast and subballast and a geotextile.

On S1 and S2 subsoil, UIC practice adds a formation layer of better material compacted to 100% Standard Proctor, against the 95% usually specified for embankment subsoil. It only works if the subsoil has a low water content (otherwise fines migrate up and spoil the crossfall) and the layer is homogeneous, without pockets of fine material.

Table 2.3-12. Required formation-layer thickness, UIC groups 1–4
Subsoil classFormation layer qualityThickness (in.)
S1S212–22
S1S38–16
S2S38–12

After Profillidis (2014), §9.5–9.7, Tables 9.2–9.3, Fig. 9.5; after UIC Code 719R (1994). Full reference under Supplemental References.

UIC track-bed thickness formula with a worked example

UIC sizes the total track bed (ballast + subballast) by adding corrections to a base value for subgrade class. The formula comes from the finite-element stress results in Figure 2.3-14:

e (in.) = N + a + b + c + d + f + g
Table 2.3-13. Terms of the UIC track-bed thickness formula
TermDepends onValues (in.)
NSubgrade classS1: 27.6 · S2: 21.7 · S3: 17.7
aUIC groupGroups 1–2 or V > 99 mph: 0 · 3–4: −2.0 · 5: −3.9 · 6: −5.9
bTie type and length LTimber (8.5 ft): 0 · concrete: (98.4 − L)/2, with tie length L in inches
cMaintenance volumeMedium: 0 · high, groups 1–5: −3.9 · high, group 6: −2.0
dAxle load22 tons: 0 · 25 tons: +2.0 · 28 tons: +4.7 · 33 tons: +9.8
fSpeedV < 99 mph: 0 · high speed on S3: 0, on S2: +2.0, on S1: +3.9
gGeotextileGeotextile thickness, or 0 if none

Book example. UIC group 4 line, 8.5-ft monoblock concrete ties, S2 subgrade, 22-ton axles, medium maintenance, 124 mph, 0.2-in. geotextile: e = 21.7 − 2.0 − 2.0 + 0 + 0 + 2.0 + 0.2 = 19.9 in. (about 20 in.). With the usual 6-in. subballast, the ballast is 14 in., close to the 15 in. that British practice would give. The same site with a frost index of 540 °F-days needs 31 in. of track bed for frost protection (Figure 2.3-29), and the larger value governs.

Figure 2.3-29. Ballast + subballast thickness required to keep frost out of the subgrade vs. frost index and mean annual temperature. Profillidis Fig. 12.6.
Figure 2.3-29. Ballast + subballast thickness required to keep frost out of the subgrade vs. frost index and mean annual temperature. Profillidis Fig. 12.6.

North American check. The formula's axle loads are metric tonnes. A 286k car on 4 axles carries about 32.4 t (35.75 short tons) per axle, at the top of the formula's range (d = +9.8 in. at 33 t). Treat the formula as a cross-check on the AREMA/Talbot thickness in this chapter, not as a substitute.

UIC subballast is usually 6 in. of well-graded gravel with Micro-Deval < 15–20 and LA < 20–25 depending on the line’s importance; some railways require at least 30% crushed stone on new lines. Some railways omit subballast and use a thicker formation layer instead.

After Profillidis (2014), §12.1.2, §12.5.1–12.5.5, Eq. 12.8. Full reference under Supplemental References.

Sub ballast in practice

Sub ballast is a compacted, well-graded sand–gravel layer 6–12 in. thick between ballast and subgrade. It is often missing on century-old mainline. It drains as part of the lateral path, adds vertical strength, and separates ballast from fine-grained subgrade in both directions. Course specification: crushed or screened pit-run gravel graded 0–3 in. or 0–¾ in., less than 8% fines, no organics, well graded, and ideally at least 50% fractured faces. Watch for contractors offering fill with more fines than specified: it compacts well dry but performs poorly once wet.

Figure 2.3-48. Fines pulled from a fouled section: what sub ballast is meant to keep separated.
Figure 2.3-48. Fines pulled from a fouled section: what sub ballast is meant to keep separated.

After Geotechnology for Railroaders Program, Module 3, Module 2; Module 3 §08; Module 2 §09. Full reference under Supplemental References.

Case study: 2.3.18.1 Zoning the best subgrade material, and losing it in the stockpile (Look 2023), in Section 2.3.18 Case Studies.

2.3.5 Subgrade Failure Modes
2.3.5.1 Progressive Shear Failure

Progressive shear occurs when σ_s exceeds the undrained shear strength of the subgrade, typically in saturated fine-grained soils under repeated loading. Manifests as pumping, subgrade mud, and progressive track settlement.

Figure 2.3-55. A subgrade cavity, invisible until it fails.
Figure 2.3-55. A subgrade cavity, invisible until it fails.

FS against progressive shear:

FS_shear = (π + 2) × s_u / (DLF × σ_s_static) ≥ 3.0 (this manual's target for cyclic loading; not an AREMA requirement)

where s_u = undrained shear strength of subgrade (psf); σ_s_static = static stress at top of subgrade (psf).

Progressive shear (cess heave): signs, monitoring and repair

Mechanism. Repeated overstress at the top of a soft, fine-grained subgrade remolds the soil and squeezes it sideways and upward beside the track. It heaves the cess (the area beside the track) and leaves a depression under the ties. The heave then walls off the side drainage, raises the water table under the track and speeds up the failure. Segmented tubing columns installed through the shoulder show whether the heave is still active.

Massive shear needs much higher stress than progressive failure. It usually happens when strength drops because of water, such as heavy rain or flooding, sometimes with no train present.

What does not work.

  • Dumping ballast into the sag deepens the granular layer locally, but the depression in the subgrade stays and becomes a water trap.
  • A general ballast lift, where clearances allow, adds stability for heavier axles. It does not restore a site that has already failed, because the deformed subgrade surface keeps ponding water.

Repair. Remove the ballast and excavate the failed subgrade to a lower, regular surface sloped to drain. Rebuild with subballast or blanket and clean ballast to the depth from Section 2.3.4.2, and restore the side drainage. The two preventive measures are adequate granular depth and drainage that keeps the water table low.

After Selig & Waters (1994), ch. 10. Full reference under Supplemental References.

Inputs for the equations in this section (2)
SymbolWhat it isComes fromHow to get itTypical range
σsstaticstatic stress at top of subgrade (psf).Another equationStress increase from the applied load: Boussinesq influence factor or 2:1 distribution (settlement chapter), or the track load-spread equations.project-specific
suundrained shear strengthLab or field testLab: UU triaxial (ASTM D2850) or unconfined compression (D2166). Field: vane shear (D2573), CPT su = (qt − σv)/Nkt, or pocket penetrometer/Torvane for screening.soft 250–500, stiff 1,000–2,000 psf · by USCS group
2.3.5.2 Ballast Pocket Formation

Ballast pockets form when fine-grained subgrade material is pumped upward through ballast voids under dynamic loading. Indicators:

  • Clay smear on ballast particles
  • Rapid track geometry degradation
  • High fouling index (see Section 2.3.6)
  • Positive mud in standpipe piezometers

Prevention: Properly designed subballast filter layer; maintain drainage; GPR monitoring.

2.3.5.3 Differential Frost Heave

Ice lens formation in frost-susceptible subgrade causes differential heave across a cross-section or along the track. Railroads in seasonal-frost regions commonly experience frost heave problems.

Differential heave threshold: FRA 49 CFR Part 213 (§213.63) limits the deviation from uniform profile on either rail to 2 in. at the midordinate of a 62-ft chord for Class 4 track (1¼ in. for Class 5).

Design mitigation:

  • Use non-frost-susceptible blanket layer (USACE FS-0 or FS-1 material) of sufficient thickness to keep the 32°F isotherm above natural subgrade
  • Required blanket thickness determined from modified Berggren equation (see Chapter 7.3, Section 7.3.6)

Frost: three conditions, and the subballast fines limit

Frost heave needs freezing temperatures, a supply of water and a frost-susceptible soil, all at once. Remove any one and heave stops. Ice lenses can heave the ground by much more than the roughly 10% volume increase of freezing water alone. On thaw, the released water softens the subgrade and geometry is lost quickly.

How susceptible the soil is depends on its type:

  • Silts are the most susceptible.
  • Clays are next.
  • Clean sands and gravels are not susceptible.

Ballast and subballast insulate the subgrade, and the required thickness is usually set by local experience. Where frost and water reach the subballast, keep its fines below about 5%. On a frost-susceptible embankment over a shallow water table, a geomembrane placed above the water table and below the maximum frost depth can cut off capillary supply (Chapter 7.2).

After Selig & Waters (1994), chs. 9 and 12. Full reference under Supplemental References.

2.3.5.4 Subgrade Attrition

Repeated cyclic loading degrades the subgrade surface through abrasion, generating fines that contaminate ballast. Most common in granular subgrades under high-axle-load traffic. Prevent with properly graded subballast and geotextile separator.

Attrition and pumping: diagnose correctly, and do not rely on fabric alone

Where it occurs. Selig and Waters tie subgrade attrition to ballast bearing on hard fine-grained soil (stiff clay) or soft rock (chalk, mudstone, shale) with standing water at the subgrade surface. The ballast grinds the surface into a slurry, and traffic pumps the slurry up to the tie, often at rail joints. The slurry then blocks the drains. This is a narrower setting than the general description above, and it matters when choosing the remedy.

Look-alikes. Ballast and tie wear in wet conditions, and plain dirty ballast, also produce mud at the surface. Before choosing a fix, compare the fines in the slurry with the subgrade, checking plasticity, color and mineralogy.

What fixes it. Two measures together:

  • A sand blanket or subballast that meets the filter criteria in Section 2.3.4.1.
  • Drainage that keeps water below the ballast–subgrade interface.

Ballast cleaning alone gives only temporary relief. British Rail made attrition failures rare by blanketing.

The record on geotextiles.

  • In laboratory pumping tests, clay pumped through every geotextile tested, including fabrics sold for this purpose.
  • At Conrail’s Pottstown site (clay-rich mudstone, water at tie bottom), slurry came through the fabric and mud boils reached the surface within 2 years at about 15 MGT per year.
  • At British Rail’s Fenny Compton trial, 2 in. of sand under geotextile and geogrid kept the ballast clean for 3 years. A geotextile plus geomembrane with no sand was the worst performer.

Design point: a sand blanket stops clay pumping, and fabric alone does not.

After Selig & Waters (1994), chs. 10 and 12. Full reference under Supplemental References.

Supplemental reference

The full family of subgrade problems

Sections 2.3.5.1–2.3.5.4 cover four subgrade problems; Li et al. recognize ten. Li et al. group them by what drives them — dead load, live (train) load, or the environment — which is a useful way to tie field symptoms back to a cause before selecting a remedy.

Figure 2.3-50. A mud hole is a substructure symptom; the cause lies below.
Figure 2.3-50. A mud hole is a substructure symptom; the cause lies below.

Table 2-S6. Characteristics of track subgrade problems (Li et al., 2016, Table 3.9)

CauseTypeContributing factorsField features
Dead loadMassive shear failureWeight of train, track and subgrade; inadequate soil strengthHigh embankments and cut slopes; often triggered by a rise in water content
Dead loadConsolidation settlementEmbankment weight; saturated fine-grained soilsIncreased static stress vs. pre-construction
Live loadSubgrade attritionBallast bearing directly on hard subgrade; clay-rich rock or soil; waterMuddy ballast; missing or inadequate subballast
Live loadCyclic mobility / liquefactionRepeated loading of saturated silt and fine sandLarge displacement; worse with vibration; can occur in subballast
Live loadProgressive shear failureRepeated overstressing of wet fine-grained soilSqueezing at subgrade surface; heave in crib or shoulder; depression under ties
Live loadCumulative plastic deformationRepeated loading of soft or loose soilDifferential settlement; ballast pockets
EnvironmentFrost actionFreezing temperatures, free water, frost-susceptible soilRough surface in winter/spring
EnvironmentSwelling / shrinkageHigh-plasticity soil with changing moistureRough track surface
EnvironmentSlope erosionSurface and subsurface water; windSoil washed or blown away
EnvironmentSoil collapseWater inundation of loose depositsGround settlement
Figure 2.3-51. Subgrade deformation beneath track.
Figure 2.3-51. Subgrade deformation beneath track.
Figure 2.3-57. End of winter: a series of ice lenses at the base of the embankment.
Figure 2.3-57. End of winter: a series of ice lenses at the base of the embankment.
Figure 2.3-59. A water-filled ballast pocket, the source of about 25% of frost heaves.
Figure 2.3-59. A water-filled ballast pocket, the source of about 25% of frost heaves.
Figure 2.3-60. Spring silt liquefaction: pale wet silt pushed up through the ballast.
Figure 2.3-60. Spring silt liquefaction: pale wet silt pushed up through the ballast.

Usman et al. (2015) add a drainage-focused view: most live-load failures on fine-grained subgrade start with water retained in the track section (fouled ballast, blocked ditches, clogged pipe drains), which softens the clay, lowers its strength and bearing capacity, and leads to shear/plastic deformation and ballast pockets. Their cause-and-effect chart (Figure 2-S4) is a practical checklist for tracing a wet spot back to the drainage element that failed. UK surveys cited in the paper found an average of about five wet spots per mile of track.

Cause-and-effect chart linking flooding, precipitation, fouling and drainage deficiencies to clay subgrade softening and progressive shear / plastic deformation.
Supplemental Figure 2-S4. Cause-and-effect chart linking flooding, precipitation, fouling and drainage deficiencies to clay subgrade softening and progressive shear / plastic deformation. Source: Usman, K., Burrow, M. and Ghataora, G. (2015). “Railway track subgrade failure mechanisms using a fault chart approach.” Procedia Engineering 125, 547–555 (open access, CC BY-NC-ND 4.0), p. 551.

Source: Li, D., Hyslip, J., Sussmann, T. and Chrismer, S. (2016). Railway Geotechnics. CRC Press / Taylor & Francis · Usman, K., Burrow, M. and Ghataora, G. (2015). “Railway track subgrade failure mechanisms using a fault chart approach.” Procedia Engineering 125, 547–555 (open access, CC BY-NC-ND 4.0)

Progressive shear failure: the subgrade surface is sheared and remolded by cyclic overstress and squeezes outward and upward along the path of least resistance (after Li and Selig).
Supplemental Figure 2-S1. Progressive shear failure: the subgrade surface is sheared and remolded by cyclic overstress and squeezes outward and upward along the path of least resistance (after Li and Selig). Source: Usman, K., Burrow, M. and Ghataora, G. (2015). “Railway track subgrade failure mechanisms using a fault chart approach.” Procedia Engineering 125, 547–555 (open access, CC BY-NC-ND 4.0), p. 548.
Excessive subgrade plastic deformation forming a ballast pocket that traps water beneath the track.
Supplemental Figure 2-S2. Excessive subgrade plastic deformation forming a ballast pocket that traps water beneath the track. Source: Usman, K., Burrow, M. and Ghataora, G. (2015). “Railway track subgrade failure mechanisms using a fault chart approach.” Procedia Engineering 125, 547–555 (open access, CC BY-NC-ND 4.0), p. 549.
Wet spot with mud pumping through the ballast &mdash; the typical surface expression of subgrade attrition and fouling.
Supplemental Figure 2-S3. Wet spot with mud pumping through the ballast — the typical surface expression of subgrade attrition and fouling. Source: Usman, K., Burrow, M. and Ghataora, G. (2015). “Railway track subgrade failure mechanisms using a fault chart approach.” Procedia Engineering 125, 547–555 (open access, CC BY-NC-ND 4.0), p. 549.

Cyclic loading: when subgrade plastic strain stops stabilizing

For soils, fatigue shows up as accumulating plastic strain rather than sudden fracture. Repeated-load triaxial tests on clays (Figure 2.3-25) use R, the ratio of the first-cycle deviator stress to the deviator stress that causes failure. Above R ≈ 0.9, plastic strain increases very rapidly with the number of cycles. Below it, strain grows roughly with log N and levels off. The runaway behavior was observed in S0 and S1 subgrades.

Figure 2.3-25. Plastic strain εp in clay vs. number of loading cycles N for stress ratios R = 0.67 to 1.03. Profillidis Fig. 9.7.
Figure 2.3-25. Plastic strain εp in clay vs. number of loading cycles N for stress ratios R = 0.67 to 1.03. Profillidis Fig. 9.7.

For the effect of traffic on subgrade stress the book uses Dormon’s rule from highway practice: σ1/σ2 = (N2/N1)λ, with λ ≈ 0.2. For two lines with the same axle load, the allowable subgrade stress therefore scales with (T2/T1)0.2: doubling tonnage lowers the allowable stress by about 13%.

Subgrade fines can also migrate upward. Figure 2.3-26 shows the combinations of plasticity index and liquid limit for which strong infiltration of subgrade fines into a gravel subballast was observed. It is a useful screen when deciding whether a separation geotextile or sand blanket is needed.

Figure 2.3-26. PI–LL zone in which strong infiltration of subgrade fines into the gravel subballast was observed. Profillidis Fig. 9.19.
Figure 2.3-26. PI–LL zone in which strong infiltration of subgrade fines into the gravel subballast was observed. Profillidis Fig. 9.19.

After Profillidis (2014), §9.8, §9.10, §9.15.2, Figs. 9.7, 9.19. Full reference under Supplemental References.

Frost index and frost-protection thickness

The frost index is the time integral of below-freezing temperature (°F × hours or °F × days). A railway must choose whether to design for the coldest winter or for an average winter and accept occasional frost penetration. Silt is very frost-susceptible, clay is susceptible, and sand and gravel are not.

Table 2.3-14. Frost index design level and expected exceedance
Frost indexProbability of freezing throughExpected number of underratings
F250%1 in a 2-year period
F520%1 in a 5-year period
F1010%1 in a 10-year period
F1001%1 in a 100-year period

The required frost-protection layer under 14 in. of ballast increases with frost index and depends on the material (gravel needs the most, peat/bark the least; Figure 2.3-27). A foam-plastic insulation board 2–4 in. thick sharply reduces the required thickness (Figure 2.3-28). On existing track, frost protection is normally installed at renewal using one of four details: a gravel or cinder layer, stone with a peat filter, foam plastic, or insulation over a frost-storage bottom layer.

Figure 2.3-27. Thickness of frost-protection layer under 14 in. of ballast vs. frost index, for gravel, cinders and peat/bark. Profillidis Fig. 9.8.
Figure 2.3-27. Thickness of frost-protection layer under 14 in. of ballast vs. frost index, for gravel, cinders and peat/bark. Profillidis Fig. 9.8.
Figure 2.3-28. Thickness of frost-protection layer under 10 in. of ballast with 50- or 4-in. foam-plastic insulation. Profillidis Fig. 9.9.
Figure 2.3-28. Thickness of frost-protection layer under 10 in. of ballast with 50- or 4-in. foam-plastic insulation. Profillidis Fig. 9.9.
Figure 2.3-30. Frost protection on existing track: gravel or cinder layer (min. 31 in., 13 ft wide). Profillidis Fig. 9.10.
Figure 2.3-30. Frost protection on existing track: gravel or cinder layer (min. 31 in., 13 ft wide). Profillidis Fig. 9.10.
Figure 2.3-31. Frost protection with foam plastic. Profillidis Fig. 9.12.
Figure 2.3-31. Frost protection with foam plastic. Profillidis Fig. 9.12.
Figure 2.3-32. Insulation combined with a drainage layer and frost-storage bottom layer. Profillidis Fig. 9.13.
Figure 2.3-32. Insulation combined with a drainage layer and frost-storage bottom layer. Profillidis Fig. 9.13.

After Profillidis (2014), §9.11, §12.5.2, Table 9.6, Figs. 9.8–9.13, 12.6. Full reference under Supplemental References.

Mud spots, cavities and silt pumping: diagnosing what is below

Before touching a mud spot, ask what kind it is and how deep the problem goes. The cause is usually ballast degradation, subgrade liquefaction and pumping, plastic deformation, subgrade failure, or poor drainage. The fix ranges from tamping (temporary) to undercutting or reinforcing the subgrade (durable). One railroad spent nearly $10M in a year on mud spots and wasted about 90% of it treating symptoms. On another system, over 95% of a $200M+/year ballast budget went into the upper 20 in. of the structure.

Figure 2.3-54. Excavation showing a mud-spot failure zone far larger than the surface symptom.
Figure 2.3-54. Excavation showing a mud-spot failure zone far larger than the surface symptom.

On a steep embankment, uncorrected ballast pockets can become a slope failure. In one silt-pumping case, an investigation trench beside sinking track showed silt rising as the track went down. The fix was filter cloth, gravel backfill and deeper ditches, which addressed the water path rather than the sinking.

Figure 2.3-53. Investigation trench with silt rising as the track sank.
Figure 2.3-53. Investigation trench with silt rising as the track sank.

After Geotechnology for Railroaders Program, Module 3; §02, §09, §11. Full reference under Supplemental References.

Frost heave and spring silt liquefaction: field mechanism and remedies

Frost heave needs five conditions at once: saturated soil, frost-susceptible soil (silt), sub-zero temperature, a slowly advancing freezing front, and a water supply from below. Remove any one and it cannot occur. About 75% of heave problems trace to poorly maintained ditches and about 25% to poor ballast drainage (ballast pockets), even on high fills. In spring, ice lenses can push the rail up several inches over 10–40 ft of track, usually by different amounts on each rail. Shimming is reactive; treat the cause.

Figure 2.3-56. Capillary water rising to the frost front, freezing into ice lenses and pushing the ground up.
Figure 2.3-56. Capillary water rising to the frost front, freezing into ice lenses and pushing the ground up.
Figure 2.3-58. Spring: rail pushed up several inches over a 10–40 ft stretch.
Figure 2.3-58. Spring: rail pushed up several inches over a 10–40 ft stretch.

Marking and salting is the most practical remedy once drainage alone is not enough. Mark the start and end of the heave tie by tie in spring, then salt in the fall; salting earlier lets rain carry the salt too deep. Provide a transition between salted and unsalted ground so a depression does not form. Other options are drainage and subdrainage, shimming, excavating and replacing silty soil, insulation and injection.

Figure 2.3-63. Salting completed: typically good for several years.
Figure 2.3-63. Salting completed: typically good for several years.

Spring silt liquefaction happens when the thawed top of a silt layer is squeezed by traffic against still-frozen ground below. Pore pressure cannot drain down, so it fractures upward and carries silt onto the shoulder. In one case cross-level moved 3–4 in. under a train. The condition clears once the frost is out. A lateral trench drain speeds recovery:

  • excavate at the point of bulging silt, down to the soft silt at the frost front, and drain any water pocket;
  • place nonwoven geotextile in direct contact with the silt;
  • backfill with free-draining angular stone compacted in lifts, which acts as a shear key; wrap the fabric over the trench about 2 ft below base of rail; finish with clean ballast sloped to a clean ditch;
  • space trenches about 15–20 ft along the weak zone; use a vacuum truck where cables are buried; record locations, since trenches may need redoing in 2–6 years.
Figure 2.3-61. Lateral trench excavated to the soft silt at the frost front.
Figure 2.3-61. Lateral trench excavated to the soft silt at the frost front.
Figure 2.3-62. Geotextile wrapped over the trench before the final ballast layer.
Figure 2.3-62. Geotextile wrapped over the trench before the final ballast layer.

After Geotechnology for Railroaders Program, Module 6.6; §02–05. Full reference under Supplemental References.

Subgrade stability first, and a screening bearing check for light-density track

If the subgrade is not stable, the track will not hold alignment, surface or cross level, however much maintenance is spent on it. Settle the subgrade before the track section. Investigate the alignment (Chapter 3.9). Design cuts, fills and subgrade preparation to AREMA Chapter 1, Part 2. Confirm soil suitability against the AREMA table of soil types and their suitability as railroad subgrade.

For cohesive subgrades, UFC 4-860-01FA sets the design bearing capacity of the track structure from the unconfined compressive strength, qu, measured at natural water content:

Table 2-S9. UFC design bearing capacity for cohesive subgrade
Annual trafficDesign bearing capacityApproximate equivalent
Less than 5 MGTqu2 su
5 MGT or more0.8 qu1.6 su

Use as a screening check only. The UFC rule was written for low-tonnage installation track. The progressive-shear check in Section 2.3.5.1 (FS ≥ 3 on (π + 2) s u ) allows a stress of about 1.7 su divided by the dynamic load factor, so the UFC rule is less conservative. Use it to screen industry, yard and light-density branch-line track. For mainline and heavy-haul track, design to Section 2.3.5.1 and the granular layer methods in Section 2.3.4.

Chemical stabilization in frost areas. Use lime or cement stabilized subgrade under track with caution in seasonal-frost areas, and only after laboratory testing that includes frost susceptibility and freeze–thaw durability (Chapter 7.2).

Figure 2.3-52. A mud “volcano”: subgrade pumping, common in cuts and high-water-table areas.
Figure 2.3-52. A mud “volcano”: subgrade pumping, common in cuts and high-water-table areas.

After UFC 4-860-01FA (2004), ch. 6, §8. Comparison with Section 2.3.5.1 added by the authors. Full reference under Supplemental References.

2.3.6 Track Modulus

Track modulus (u) characterizes the stiffness of the combined track-subgrade system. It is the support force per unit length of rail per unit of rail deflection (beam on elastic foundation):

Track stiffness: k = P_w / w_max (lb/in.)

Track modulus follows from the measured stiffness (Equation 2.3-4):

u = k^(4/3) / (64 EI)^(1/3) (lb/in./in., often written psi)

where:

  • P_w = wheel load (lb)
  • w_max = maximum rail deflection under wheel load (in.)

Typical track modulus values:

Table 2.3-4. Typical Track Modulus by Condition
Conditionu (lb/in./in.)Rating (Table 2.3-23)
Soft subgrade, worn ballast1,000–2,000Poor
Average track, mixed subgrade2,000–4,000Average
Good track, granular subgrade4,000–6,000Good
High-quality concrete tie, stiff subgrade6,000–8,000Within suggested optimum
Stiff track on a very stiff subgrade> 8,000Stiff; check dynamic loads

Track modulus directly affects bending moment and deflection in the rail. The characteristic length:

l = (4EI / u)^(1/4) (in.)

where:

  • E = rail elastic modulus = 30 × 10⁶ psi
  • I = rail moment of inertia (in.⁴); 136 RE rail: I = 95.0 in.⁴; 141 RE: I = 103.1 in.⁴
  • u = track modulus (psi)

The maximum rail bending moment:

M_max = P_w × l / 4 (in.·lb)

Higher track modulus reduces deflection but increases dynamic impact forces. A modulus of about 2,000 lb/in./in. is the commonly cited minimum for satisfactory performance, and heavy-axle and high-speed owners usually aim higher (Table 2.3-23). Confirm targets with the owner railroad.

Supplemental reference

Measuring trackbed stiffness in the field

McHenry and Rose (2012) reviewed the in-situ tests available for railroad subgrade. Beyond borings and CPT, the options most relevant to track modulus are:

  • Dynamic cone penetrometer (DCP) and PANDA — hand-driven cones that locate ballast/subballast/subgrade interfaces and give a strength profile from the shoulder or crib. The PANDA records blow energy and penetration electronically.
  • Falling weight / light weight deflectometer (FWD, LWD; ASTM D4694) — drop a known weight and back-calculate a layer modulus (EFWD = 0.24P / (dr·r)). Widely used on highway subgrade; LWD is increasingly used on new rail formations in Europe and Asia.
  • Seismic CPT — adds shear-wave velocity, giving a small-strain modulus that better matches the small cyclic strains under train loading than a resilient modulus does.
  • Rail-bound stiffness vehicles — the TTCI Track Loading Vehicle (Pueblo, CO), the Chinese Academy of Railway Sciences two-car system, the University of Nebraska laser deflection system, and the French Portancemètre measure track stiffness continuously. Their output is the best way to pick boring locations on long corridors.
How Does a Railway Track Transfer Train Load to Soil?
How Does a Railway Track Transfer Train Load to Soil?

Source: McHenry, M. and Rose, J. (2012). Railroad Subgrade Performance Indicators — A Review of Available Testing Methods. University of Kentucky

Reaction coefficients, ballast thickness and the stiffness balance

Profillidis expresses stiffness as a reaction coefficient ρ = load / settlement at the level considered (56 kip/in. per t/mm in the source). Typical component values are: rail 280,000–560,000 kip/in.; timber tie 50–80; concrete tie 1,200–1,500; ballast 10–30; rubber pad 560–1,120 kip/in.. The subgrade is the softest element in the chain:

Figure 2.3-33. Elastic line (deflected shape) of a timber tie on rock and on S3, S2 and S1 subgrades under two 11-ton loads. Profillidis Fig. 8.12.
Figure 2.3-33. Elastic line (deflected shape) of a timber tie on rock and on S3, S2 and S1 subgrades under two 11-ton loads. Profillidis Fig. 8.12.
Table 2.3-15. Subgrade reaction coefficients
Subgradeρ (kip/in.)
Silty28–84
Clay84–112
Gravel or rock112–450
Frozen450–560

Existing track with ballast only (no subballast): total ρ = 8.4–56 kip/in., average 17 kip/in.. Bridges: 560–840 kip/in..

Table 2.3-16. Effect of ballast thickness e on subgrade stress and track stiffness (Boussinesq, multilayer elastic)
e (in.)068121620
λ (subgrade stress ratio)10.700.500.350.250.20
ρ / ρ011.402.002.854.005.00

Design should satisfy two principles: stresses reaching the subgrade must stay below failure values, and the track must remain flexible. A rock subgrade is more than three times as stiff as a clay subgrade, so even rock cuts need a full ballast and subballast section. In the finite-element breakdown (Figure 2.3-34), the subgrade supplies about 40–43% of total track elasticity, the track bed 20–22% and the rail pads 25–34%.

Figure 2.3-34. Contribution of each component to total track elasticity, timber vs. concrete ties. Profillidis Fig. 8.16.
Figure 2.3-34. Contribution of each component to total track elasticity, timber vs. concrete ties. Profillidis Fig. 8.16.

After Profillidis (2014), §8.2.2–8.2.3, §8.4.9, §8.8, Table 8.1, Figs. 8.12, 8.16. Full reference under Supplemental References.

Measuring track modulus: method, slack and nonlinearity

Track modulus lumps the fastenings, ties, ballast, subballast and subgrade into one spring. It cannot be calculated from the components. It has to be measured. Selig and Waters describe three methods:

  • Single point load (preferred). Measure the maximum rail deflection under one load: u = [P / (2 ymax)]4/3 / (4 EI)1/3 = ¼ (EI)−1/3 (P / ymax)4/3. This follows from ymax = Pβ / (2u) with β = [u / (4 EI)]1/4 (Winkler beam on elastic foundation; Hetényi 1946; Selig and Waters 1994, Ch. 14).
  • Deflection basin (Talbot). The load equals u times the area of the deflection basin. This averages over a length of track.
  • Multi-axle vehicle. Convenient, but it relies on superposition.

Remove slack. With all three methods, use the difference between a light seating load and a heavy load. This removes gaps and slack under the ties. Load–deflection curves are strongly nonlinear, and more so as track settles, so always report the load levels with the modulus.

Field values and correlation. At eight U.S. sites, u ranged from 2,200 to 7,000 psi. CPT soundings to at least 16 ft below the tie, back-analyzed with a multilayer model, gave a subgrade resilient modulus of about Er ≈ 14 qc for all the data, or about 21 qc with outliers removed. This makes CPT a practical way to estimate track stiffness along a corridor.

Sensitivity. In the model, fastener stiffness had the largest effect on u, but it varies little in real track (about 10%). Ballast modulus, ballast depth, tie spacing and rail section each changed u by 10–20%. The subgrade remains the most influential variable in the field.

After Selig & Waters (1994), chs. 5 and 10. Full reference under Supplemental References.

Empirical equation note · this section

Values from these correlations are estimates, not test results. State the equation ID and source when one is used, confirm the soil or rock is within its range, and calibrate against site testing before design.

  • IS-18 Shear-wave velocity from CPT VₛUse: Young, uncemented Holocene–Pleistocene soils. Limits: Underpredicts Vs in aged or cemented soils. Measure Vs directly for seismic site class.
  • RK-10 UCS from point load index σ꜀Use: Hard, isotropic rock; quick strength index in field. Limits: K varies widely with rock type and anisotropy; calibrate with lab UCS. Unreliable in weak rock (σc < ~3,600 psi).
2.3.6.1 Track Modulus and Rail Deflection

Track modulus u is the support force per unit length of rail per unit of rail deflection. It lumps the fasteners, ties, ballast, subballast and subgrade into one spring bed under the rail. The beam-on-elastic-foundation model that defines it is too simple to give stresses inside the substructure (Chapter 2.1 uses a multilayer model for that), but u remains the standard single number for track support, and it can be measured directly from rail deflection under a known load.

2.3.6.1.1 Method

Equation 2.3-3. Beam on elastic foundation (one wheel load P)

β = [u/(4EI)]1/4   δ0 = Pβ/(2u)   M0 = P/(4β)   q0 = uδ0

Away from the load: δ(x) = (Pβ/2u)e−βx(cosβx + sinβx) and M(x) = (P/4β)e−βx(cosβx − sinβx); wheels are superposed.

Equation 2.3-4. Track stiffness and modulus from a measured deflection

k = P/δ0   u = k4/3/(64EI)1/3

Track stiffness k includes the rail's bending rigidity; track modulus u does not.

Table 2.3-22. Rail moments of inertia (North American sections)
Rail100 RE115 RE132 RE136 RE140 RE
I (in.4)49.065.688.294.996.8
Table 2.3-23. Track modulus as a measure of support
Track modulus (lb/in./in.)Rating
Below 2,000Poor; 2,000 is the commonly cited minimum for satisfactory performance
2,000 to 4,000Average
Above 4,000Good
5,000 to 10,000Suggested optimum range

Parametric studies show the subgrade modulus dominates: raising it from about 2,000 to 20,000 psi raised the track modulus roughly eightfold, while granular layer thickness and modulus had a much smaller effect. A thicker soft subgrade over rock lowers the modulus. Below about 4,000 lb/in./in., deflections and subgrade stresses rise steeply, which is why soft-subgrade sites show up first in track geometry records.

2.3.6.1.2 Worked example: 136 RE rail, two-wheel truck

Table 2.3-24. 39-kip wheels at 70 in., u = 3,000 lb/in./in., ties at 19.5 in. (calculator output)
ResultValue
Characteristic length 1/β44.1 in.
Rail deflection under a wheel (both wheels acting)0.177 in.
Rail bending moment under a wheel340.9 kip-in.
Rail-seat load10.4 kips
Measured case: 20 kips gives 0.10 in. deflection; track modulus2,063 lb/in./in.

The second wheel adds about a fifth to the deflection but reduces the moment, because at 70 in. it sits beyond the point where the moment under a single wheel changes sign. The measured case (20 kips producing 0.10 in.) back-calculates to about 2,060 lb/in./in., at the bottom of the average range.

Open the track modulus calculator →
Rail deflection, moment and rail-seat load for one or two wheels from an assumed track modulus, or track stiffness and modulus from a measured load and deflection.

Example 2.3-7: Rail Deflection, Moment and Track Modulus for a Two-Wheel Truck

Table 2.3-24 gives calculator output for 136 RE rail. Worked by hand, the example shows how a second wheel adds to the deflection under the first but reduces the moment, and how a measured deflection gives the track modulus.

Ties at s = 19.5 in.; field: 20 kips → 0.10 in.P = 39 kipsP = 39 kipsa = 70 in.springs: track modulus ul, ymax, Mmax, rail-seat load = ?u from measured case = ?GivenTwo-wheel truck, 39 kips per wheelWheel spacing a = 70 in.EI = 30×10⁶ × 94.9 in.⁴ (136 RE)Assumed u = 3,000 lb/in./in.Tie spacing 19.5 in.Measured: 20 kips gives 0.10 in.RequiredCharacteristic length, deflection,moment, rail-seat loadTrack modulus from field caseBlack = given; red = required
Given and required for Example 2.3-7.

Given

VariableValueDescription
P39 kips per wheelWheel load
a70 in.Wheel spacing
E I30 × 106 psi × 94.9 in.4136 RE rail (Table 2.3-22)
u3,000 lb/in./in.Assumed track modulus
s19.5 in.Tie spacing
Measured20 kips gives 0.10 in.Field load and deflection for the back-calculation

Required

  • Characteristic length, deflection, moment and rail-seat load
  • Track modulus from the measured case

Equations

  1. Eq. 1 (Equation 2.3-3): 1/β = (4EI / u)1/4 — characteristic length
  2. Eq. 2: δ = (Pβ / 2u)[1 + e−βa(cosβa + sinβa)] — deflection under one wheel with the second superposed
  3. Eq. 3: M = (P / 4β)[1 + e−βa(cosβa − sinβa)] — moment under one wheel
  4. Eq. 4: q = u δ s — rail-seat load
  5. Eq. 5 (Equation 2.3-4): k = P/δ0; u = k4/3 / (64EI)1/3 — track stiffness and modulus from a measurement

Steps

Step 1 · Characteristic length (Eq. 1)
(4 × 30×106 × 94.9 / 3,000)1/4 = (3.80×106)1/4
1/β = 44.1 in.
↓
Step 2 · Second-wheel term
Uses: βa = 70 / 44.1 = 1.59
e−1.59 = 0.205; cos 1.59 = −0.015; sin 1.59 = 1.000
Deflection multiplier 1 + 0.202 = 1.20; moment multiplier 1 − 0.208 = 0.79
↓
Step 3 · Deflection (Eq. 2)
39,000 / (2 × 3,000 × 44.1) = 0.147 in. × 1.20
δ = 0.177 in.
↓
Step 4 · Moment (Eq. 3)
39,000 × 44.1 / 4 = 430 kip-in. × 0.79
M = 341 kip-in.
↓
Step 5 · Rail-seat load (Eq. 4)
3,000 × 0.177 × 19.5
q = 10.4 kips
Spot check: About 27% of the wheel load, typical for this tie spacing.
↓
Step 6 · Track modulus from the measurement (Eq. 5)
k = 20,000 / 0.10 = 200,000 lb/in.; u = 200,0004/3 / (64 × 30×106 × 94.9)1/3 = 1.168×107 / 5,670
u = 2,060 lb/in./in.
↓
Solution
δ = 0.177 in.; M = 341 kip-in.; q = 10.4 kips; measured u = 2,060.

Solution

1/β = 44.1 in.; deflection 0.177 in.; moment 341 kip-in.; rail-seat load 10.4 kips. The measured case gives u = 2,060 lb/in./in.

The second wheel sits beyond the point where the single-wheel moment changes sign, so it adds about a fifth to the deflection but takes about a fifth off the moment. The measured modulus of about 2,060 is at the bottom of the average range of Table 2.3-23; soft subgrade is the usual reason, and it is the first thing to check before more ballast is added.

2.3.6.1.3 Sources in the library

These documents are in the reference library. The method summaries above are paraphrased; equations are standard or published forms.

  • Railway Geotechnics (Li, Hyslip, Sussmann and Chrismer, 2016), Chapter 4: beam on elastic foundation, track stiffness and modulus, GEOTRACK parametric study, modulus as a measure of support.Find source ↗
  • Track Geotechnology and Substructure Management (Selig and Waters, 1994), Chapter 2: rail section properties.Find source ↗Library entry
  • Qualitative Analysis for Dynamic Behavior of Railway Ballasted Track (thesis), Ballast folder.Find source ↗Library entry
2.3.7 Ballast Fouling Index

Ballast fouling reduces drainage capacity and increases subgrade stress. The Fouling Index (FI) quantifies fouling:

Figure 2.3-65. A failed area: new ballast on top, almost none functionally present beneath.
Figure 2.3-65. A failed area: new ballast on top, almost none functionally present beneath.

FI = P₄ + P₂₀₀

where:

  • P₄ = percent passing No. 4 sieve (%)
  • P₂₀₀ = percent passing No. 200 sieve (%)
Table 2.3-5. Ballast Fouling Categories (AREMA MRE Ch. 1, Table 1-2-3; recommended actions are this manual's)
FI ValueFouling ConditionRecommended Action
< 1CleanNo action; monitor
1–10Moderately cleanMonitor; plan maintenance
10–20Moderately fouledSchedule ballast cleaning
20–40FouledImmediate ballast cleaning
> 40Highly fouledBallast undercutting; possible subgrade work

Many railroads track fouling condition through periodic ballast sampling programs. Include fouling index data in geotechnical reports for mainline rehabilitation projects. GPR can estimate fouling condition non-destructively (Section 2.3.9).

Supplemental reference

Where the fouling actually comes from

Selig and Waters (1994) examined the source of fouling material at a large set of sites. Breakdown of the ballast itself was the major source at 76% of sites; upward migration from an underlying granular layer (usually old roadbed mixed in at the interface) was the major source at 13%. Contamination pumped up from the subgrade was rare. Li et al. point out that muddy ballast is often wrongly blamed on subgrade pumping when it is really ballast abraded under traffic in the presence of water — which changes the remedy from subgrade treatment to ballast renewal and drainage.

Field-friendly fouling criteria

The Selig fouling index depends on the percent passing the No. 200 sieve, which is hard to measure reliably in the field. The railroad uses the percent passing the ¾-in. sieve instead; Sussmann et al. (2012) matched the two scales:

Table 2-S4. Selig & Waters fouling index vs. A Class I railroad ¾-in. sieve criterion

CategoryFouling index (Selig & Waters)% passing ¾ in.
Clean< 1–
Moderately clean1 to < 10< 25
Moderately fouled10 to < 2025–40
Fouled20 to < 4040–50
Highly fouled> 40> 50

Table 2-S5. Ballast cleaning intervention limits used by different agencies

Agency / sourceCriterionLimitBasis
Selig & WatersFouling index40 / 30Highly fouled / drainage reduction
SpoornetFISpoornet = 0.4P19 + 0.3P6.7 + 0.2P1.18 + 0.1P0.1580Gradation change
Class I% passing ¾ in. (¾ in.)40%Highly fouled
UIC% passing ½ in. (½ in.)30%–
ERRI% passing ⅞ in. (⅞ in.)30%–

For field sampling programs, the single-sieve Class I railroad criterion lets the crew classify a sample at the tie end without shipping it to the lab; reserve full gradations (and FI) for representative samples and design stations.

Figure 2.3-66. Full undercutter in operation.
Figure 2.3-66. Full undercutter in operation.

Source: Li, D., Hyslip, J., Sussmann, T. and Chrismer, S. (2016). Railway Geotechnics. CRC Press / Taylor & Francis

Ballast cleaning trigger, renewal cycle and reuse

  • Cleaning trigger: ballast cleaning machines are used when grains smaller than 0.87 in. make up more than 30% of the ballast volume. The cleaner removes all stone smaller than 1.4 in. to a depth of 10 in. below the tie, at about 1,300 ft of track per hour.
  • Cycles on main lines: tamping every 3–5 years; ballast replacement every 15–30 years depending on stone strength and traffic (15–20 years on high-speed lines, against about 50 years for concrete ties and rail). Ballast stone tolerates only a limited number of tamping cycles.
  • Longer life: harder stone, a wider ballast section and more uniform compaction lengthened the Swiss tamping interval from 4 to 7 years and cut maintenance cost by 40% over 10 years.
  • Reuse: fouled ballast removed from track weighs about 106 pcf against 94 pcf new. If strength remains, washed spent ballast can be reused as subballast or formation layer on secondary lines, or as ballast on lines under 87 mph after treatment. France removes about 1 million tons per year this way; disposal costs (up to €60/t) often make reuse economic.
  • Vegetation contaminates ballast with debris that blocks drainage, accelerates tie decay by root expansion and hides defects from visual inspection.
Figure 2.3-67. Twelve inches of clean ballast beneath the ties, correctly profiled.
Figure 2.3-67. Twelve inches of clean ballast beneath the ties, correctly profiled.

After Profillidis (2014), §12.7, §16.8–16.9, §16.12, §9.16, Figs. 9.21, 16.10. Full reference under Supplemental References.

Fouling sources, the failure zone, and choosing a repair

Fouling comes mainly from particle breakdown under traffic, plus abraded tie material, spilled lading (coal, grain), wind-blown sand and silt, slurry pumped up from the subgrade, chemical weathering, and maintenance tools (tamping accelerates breakdown). Gradation testing shows a failure zone. Once material finer than ¾ in. passes about 25% (the ideal point to undercut) and heads toward 40% (action mandatory), degradation accelerates sharply, typically within 500 MGT. Ballast next to an active mud spot is usually near its own failure zone. Visual inspection is not enough; use sieve analysis or GPR.

Table 2.3-19. Ballast repair options when ballast is fouled
MethodCost / durationResult
TampingLow cost, very short termLow efficiency: “tamping mud”
Skin liftLow short-term costOut of the mud temporarily
Major liftMediumLonger term, but the problem may return
Shoulder cleaningMediumBetter if ballast is not too fouled; can extend ballast life
Full-depth undercuttingHighGreatest gain in internal drainage and bearing; about 15 years at 50 MGT/year

Undercut to about 12 in. below the ties, with the bar inclined to leave a 2% slope that drains to ditches or shoulders. Plan depths so every track drains on multiple-track territory, and place waste where it neither blocks drainage nor loads the shoulder. Undercutting without restoring lateral drainage gives minimal benefit. Watch for buried fiber. A documented move from reactive to planned ballast management cut ballast-related slow orders from over 600 to under 20 per year, ballast derailments from about 8 to about 0, and spending from over $250M to under $100M per year.

Figure 2.3-35. Ballast profiling machine restoring the shoulder section. Profillidis Fig. 16.10.
Figure 2.3-35. Ballast profiling machine restoring the shoulder section. Profillidis Fig. 16.10.
Figure 2.3-36. Track zones for vegetation control: inter-track (A), ballast (B), shoulder (C1, C2), walkway (D1, D2), slope (E), drainage channel (F). Profillidis Fig. 9.21.
Figure 2.3-36. Track zones for vegetation control: inter-track (A), ballast (B), shoulder (C1, C2), walkway (D1, D2), slope (E), drainage channel (F). Profillidis Fig. 9.21.
Figure 2.3-68. Ballast problems under reactive maintenance.
Figure 2.3-68. Ballast problems under reactive maintenance.
Figure 2.3-69. The same metrics after criteria-based planned maintenance.
Figure 2.3-69. The same metrics after criteria-based planned maintenance.

After Geotechnology for Railroaders Program, Module 3; §06–07, §13. Full reference under Supplemental References.

What fouling does to drainage and settlement, and how to limit it

Table 2-SW4. Ballast hydraulic conductivity by fouling index (after Parsons)
ConditionFouling indexkh, in./skh, mm/s
Clean< 11–225–50
Moderately clean1–90.1–12.5–25
Moderately fouled10–190.06–0.11.5–2.5
Fouled20–390.0002–0.060.005–1.5
Highly fouled≥ 40< 0.0002< 0.005

Settlement. In box tests, settlement increased with fouling index. A small gap under the tie (0.039–0.16 in. of lift-off between loads) increased settlement by about an order of magnitude and accelerated both fouling and tie wear. Highly fouled ballast that settles quickly after tamping is a sign that it needs cleaning.

Sources vary by railway. British Rail attributed its fouling as follows:

  • External sources (spillage, airborne): 52%.
  • Attrition: 21%.
  • Tamping: 20%.
  • Delivered with the ballast: 7%.

North American sites were dominated by ballast breakdown (see above). Sample before assuming the source. In BR tests, 20 tamping insertions broke 15–45% of the 1½–2-in. particles, and each tamp produced 4–9 lb of material finer than ½ in.

Not all fines are equal. Sand and gravel fouling is tolerable. Silt forms an abrasive slurry. Clay fouling may require 100% ballast replacement.

Figure 2.3-64. Fouled ballast: fines filling the voids that should drain water.
Figure 2.3-64. Fouled ballast: fines filling the voids that should drain water.

Six ways to limit fouling:

  • Deliver ballast clean.
  • Limit spillage from cars.
  • Tamp only when geometry requires it.
  • Specify attrition-resistant stone.
  • Keep the ballast drained.
  • Provide a blanket over fine-grained subgrade.

Undercut or clean at a fouling index of about 40 if the ballast is cleanable. Plow or sled it out if it is fouled with wet, plastic fines.

After Selig & Waters (1994), chs. 8, 13 and 16. Full reference under Supplemental References.

2.3.8 Subgrade Drainage Design

Poor drainage is the single most common root cause of subgrade problems in North American railroad practice. The geotechnical consultant is responsible for assessing existing drainage adequacy and designing improvements.

Road Drainage Fundamentals
Road Drainage Fundamentals
Culverts
Culverts
2.3.8.1 Drainage Design Criteria

Required drainage capacity:

Q = C × i × A (ft³/s) [Rational Method]

where:

  • C = runoff coefficient (about 0.20–0.40 for railroad yards, FHWA HDS-2; higher where the catchment includes pavement or other impervious areas)
  • i = design rainfall intensity (in./hr) for a duration equal to the time of concentration, at the return period the owner railroad specifies
  • A = drainage catchment area (acres)

Subgrade drainage outlet spacing:

Space outlets to suit the track grade, the ditch or pipe capacity and the owner railroad's standards. Provide an outlet at every sag in the vertical profile.

Inputs for the equations in this section (5)
SymbolWhat it isComes fromHow to get itTypical range
Crunoff coefficient (about 0.20–0.40 for railroad yards, FHWA HDS-2; higher where the catchment includes pavement or other impervious areas)Hydraulic studyFrom the hydraulic model or study (HEC-RAS, FHWA HEC-18), stream gauge records or the drainage design.project-specific
idesign rainfall intensity (in./hrPublished hazard / climate dataNOAA Atlas 14 precipitation-frequency data for the design storm and return period.project-specific
Adrainage catchment area (acres)Hydraulic studyFrom the hydraulic model or study (HEC-RAS, FHWA HEC-18), stream gauge records or the drainage design.project-specific
inetnet lateral hydraulic gradient.Chart, table or correction factorRead from the cited chart or table for the site conditions; values listed in the definition.project-specific
wwater contentLab testOven-dry water content of samples (ASTM D2216); field check by microwave (D4643) or nuclear gauge (D6938).gravels/sands 3–25%, clays 15–70% · by USCS group
2.3.8.2 Edge Drain Design

Perforated pipe edge drains at the base of the subballast layer are common on new mainline construction; confirm the owner railroad's standard. Design:

Anatomy of a Modern Road — Layers, Geogrid & Subdrainage
Anatomy of a Modern Road — Layers, Geogrid & Subdrainage

Pipe diameter: 4 in. minimum perforated HDPE; 6 in. for grades < 0.5%

Filter requirements: size the geotextile wrap with the FHWA geosynthetic filter criteria (Holtz et al., FHWA-NHI-07-092):

AOS (O₉₅) ≤ B × D₈₅ of the retained soil, with B = 1 as a conservative value (retention)

k_geotextile ≥ 10 × k_soil for critical applications, ≥ k_soil otherwise (permeability)

Groundwater depth, crossfall and geotextile filters

UIC guidance is that the groundwater level should be at least 2.6 ft below the top of subgrade. Where it is not, it must be lowered with ditches or deep drains. Individual railways set their own minimum depths below rail or formation (Figure 2.3-37). Even where groundwater is deep enough, hydrogeological conditions are not rated “good” unless drainage devices are provided and the top of subgrade has a 3–5% crossfall. Sites with large seasonal groundwater fluctuation need a separate study, where a sand filter or geotextile may be warranted.

Figure 2.3-37. Minimum depth of groundwater below a reference level for “good” hydrogeological conditions, by railway (DB, SBB, SJ, VR, NSB, OBB, SNCF, BR). Profillidis Fig. 9.3.
Figure 2.3-37. Minimum depth of groundwater below a reference level for “good” hydrogeological conditions, by railway (DB, SBB, SJ, VR, NSB, OBB, SNCF, BR). Profillidis Fig. 9.3.
Figure 2.3-38. Drainage devices along the railway subgrade: crossfall to side drains, base drainage. Profillidis Fig. 9.4.
Figure 2.3-38. Drainage devices along the railway subgrade: crossfall to side drains, base drainage. Profillidis Fig. 9.4.

Geotextiles (polypropylene or polyester, 0.016–0.12 in. thick, woven or non-woven) separate, reinforce, filter and drain. They go under the subballast, never directly under the ballast. They do not replace ballast or subballast for load spreading: railways that laid a geotextile and also cut ballast thickness or omitted subballast saw the ballast puncture the fabric and lost the crossfall. A finite-element study found about a 10% reduction in stress at the top of subgrade from the geotextile. Filter permeability criteria quoted by the book:

Figure 2.3-39. Finite-element mesh used to assess the reinforcing effect of a geotextile under a track bed. Profillidis Fig. 9.20.
Figure 2.3-39. Finite-element mesh used to assess the reinforcing effect of a geotextile under a track bed. Profillidis Fig. 9.20.
non-cohesive soils: kg ≥ tg·ks / (5·d50)     cohesive soils: kg > 100·ks

where kg = geotextile permeability (ft/day), tg = geotextile thickness (in.), ks = soil permeability (ft/day) and d50 = soil 50% passing size (in.).

After Profillidis (2014), §9.4, §9.14.1, §9.15, Eqs. 9.13–9.14, Figs. 9.3, 9.4, 9.20. Full reference under Supplemental References.

Internal drainage on multiple tracks, and why it blocks

On double track, each track drains laterally away from the centerline. On three or more tracks, the outside tracks drain outward and the inner tracks drain into longitudinal trench drains, with the subgrade and sub-ballast surfaces sloped to suit. Ballast-deck bridges need their own designed drainage. Lateral drainage blocks when there is no cross-slope, when ballast pockets have formed, or when material and vegetation build up between the ballast toe and the ditch. Water trapped in the ballast is the leading cause of mud-fouled ballast. Groundwater seepage, where the subgrade sits at or below a fluctuating water table, is the second.

Cross-section diagram of a prefabricated geocomposite edge drain in a trench, showing a 25 to 50 millimeter drainage core width and a 0.3 to 0.45 meter trench d
Photo 2.3.8-1. Prefabricated geocomposite edge drain (PGED). Koerner et al. (1996).Source: FHWA / SHRP2 R02, GeoTechTools.org technology photo sheet.
Black-and-white photograph of a truck spraying prime coat onto a roadway surface, with hills and trees in the background
Photo 2.3.8-2. Prime coat application on top of geocomposite membrane. From Elseifi, M., Al-Qadi, I., Loulizi, A., and Wilkes, J. (2001), Transportation Research Record 1772, Figure 2, p. 169. Copyright, National Academy of Sciences, Washington, D.C., 2001. Reproduced with permission of the Transportation Research Board.Source: FHWA / SHRP2 R02, GeoTechTools.org technology photo sheet.
An edge drain trench lined with geotextile and filled with aggregate along a roadway under construction, with a bulldozer and bridge visible in the distance
Photo 2.3.8-3. Geotextile in pavement drainage. From National Highway Institute Lecture notes.Source: FHWA / SHRP2 R02, GeoTechTools.org technology photo sheet.
Figure 2.3-70. Double track: each track drains away from the centerline.
Figure 2.3-70. Double track: each track drains away from the centerline.
Figure 2.3-71. Three or more tracks: inner tracks drain to longitudinal trench drains.
Figure 2.3-71. Three or more tracks: inner tracks drain to longitudinal trench drains.
Figure 2.3-72. Blocked lateral drainage: no cross-slope, ballast pockets, or buildup at the toe.
Figure 2.3-72. Blocked lateral drainage: no cross-slope, ballast pockets, or buildup at the toe.
Figure 2.3-73. Water trapped in the ballast layer.
Figure 2.3-73. Water trapped in the ballast layer.
  • Move water away from below the ties as quickly as possible.
  • Keep ballast and shoulders clean and permeable.
  • Keep the subgrade dry; drain ballast water pockets.
  • Do not let water pond in ditches, especially in side-hill cuts.

After Geotechnology for Railroaders Program, Module 4; §03, §05–06. Full reference under Supplemental References.

Can the ballast section drain the design storm?

Three requirements. Track drainage works only if all three are met:

  • The ballast is clean enough to pass water as fast as it enters.
  • The subballast and subgrade surfaces slope to the sides.
  • An outlet carries the water away. A section with no outlet is a bathtub.

Size the system for the highest inflow expected over its design life, not the average.

The center of the track ponds first. On a low-permeability subgrade, water flows mostly sideways. About two-thirds of it leaves through the shoulders. The zone within about 12 in. of the track centerline has the longest flow path and saturates first, so it sets the critical rainfall rate.

Table 2-SW5 gives the critical rainfall rate for several ballast conditions. The cases assume 12 in. of ballast below the tie and 6 in. of silty-sand subballast on an impermeable subgrade.

Table 2-SW5. Rainfall rate that saturates the center of the track section (Parsons cases)
Ballast conditionCritical rate, in./hr
Clean5.9
Clean shoulders; fouled (FI 30) below1.4
Undercut, over FI 30 ballast0.33
Undercut, over FI 40 ballast0.31
Fouled throughout (FI 30)0.06
Clean shoulders; highly fouled (FI 40) below0.02
Highly fouled throughout (FI 40)0.001

Double track that drains to one side only has about half these critical rates.

How to use it.

  • Compare the critical rate with the design rainfall intensity over the planned cleaning cycle to set an allowable fouling index.
  • For moderately fouled track, shoulder cleaning beats undercutting.
  • For highly fouled track, undercutting is better, because water under the center would otherwise have to pass through fouled ballast to reach the cleaned shoulders.
  • Full cleaning is best.

After Selig & Waters (1994), ch. 13. Full reference under Supplemental References.

Case study: 2.3.18.2 Rail formation on broken hard rock: ruts after a week, tests all passed (Look 2023), in Section 2.3.18 Case Studies.

2.3.9 Ground-Penetrating Radar (GPR) for Ballast Assessment

GPR is an efficient, non-destructive tool for mapping ballast fouling, subballast thickness, and subgrade moisture conditions along track. It is common practice for mainline rehabilitation investigations.

2.3.9.1 GPR Method Overview

GPR uses an antenna (typically 400 MHz or 1 GHz) mounted on a hi-rail vehicle to transmit and receive electromagnetic pulses through the track structure. Reflections at material boundaries provide:

  • Ballast/subballast interface depth
  • Subballast/subgrade interface depth
  • Areas of fouled or wet ballast (higher dielectric constant)
  • Subgrade anomalies (mud pockets, voids, wet zones)
2.3.9.2 GPR Interpretation — Dielectric Constant

The depth to a reflector:

d_GPR = (v × t_twtt) / 2 (ft)

where:

  • v = electromagnetic wave velocity in ballast (ft/ns); v = c / √ε_r
  • c = speed of light = 0.984 ft/ns
  • ε_r = relative dielectric constant of ballast (clean ballast: ε_r ≈ 3–4 measured, 5–6 often assumed; fouled/wet ballast: ε_r ≈ 10–30; see Table 2.3-25)
  • t_twtt = two-way travel time (ns) from radar trace
Ground Penetrating Radar
Ground Penetrating Radar
Table 2.3-6. GPR Dielectric Constants for Track Materials
Materialε_rWave Velocity (ft/ns)
Clean ballast, dry to moist (measured)3–40.492–0.568
Clean granite ballast (value often assumed in practice)5–60.402–0.440
Moderately fouled ballast8–120.284–0.348
Highly fouled/saturated15–300.180–0.254
Subballast (granular, dry)6–90.328–0.402
Clay subgrade (moist)20–400.156–0.220
Ballast voids/air10.984

Note: the clean-ballast row was revised to the measured values of 3 to 4 (Table 2.3-25 at the end of this section). The 5 to 6 often assumed is kept for comparison. Calibrate each survey at crib digs or by CMP.

Inputs for the equations in this section (4)
SymbolWhat it isComes fromHow to get itTypical range
velectromagnetic wave velocity in ballast (ft/ns)Field test (geophysics)From the dielectric constant, v = c/√εr, or measured directly by a common-midpoint (CMP) or wide-angle GPR survey (ASTM D6432).project-specific
cspeed of light = 0.984 ft/nsConstantPhysical constant or standard value.project-specific
εrrelative dielectric constant of ballast (clean ballast: ε_r ≈ 3–4 measured, 5–6 often assumed)Field test (geophysics)Back-calculated at a crib dig or boring of known depth, εr = (c·t/2d)2, or from a CMP survey. Laboratory values by ballast type, fouling and moisture are in Table 2.3-26.≈ 3–4 clean (measured); calibrate
ttwtttwo-way travel time (ns) from radar traceField test (geophysics)Read from the GPR record (ASTM D6432). Where the fouled zone has no sharp interface, use the depth of the energy drop on a short-time Fourier transform (STFT) plot.project-specific
2.3.9.3 GPR Deliverables

Standard GPR deliverables for railroad geotechnical investigations:

  • Continuous color-coded fouling index map along alignment (1 ft spatial resolution)
  • Ballast depth profiles (both rails and center)
  • Subballast thickness profile
  • Anomaly log (GPS-referenced stations flagging mud pockets, thin layers, wet zones)
  • Correlation borings recommended at anomaly stations (typically 1 boring per 5 anomaly locations)

Correlate GPR survey results with field-verified boring data before design recommendations are finalized.

Supplemental reference · Saarenketo, in Jol (ed.) (2009)

Railway GPR Practice: Antennas, Dielectric Values and Survey Lines

GPR on track is harder than on pavement. The rails and ties, especially concrete ties, and nearby electrical wires interfere with the signal, and dense sampling at track speed was long a problem for scheduling (Saarenketo, in Jol 2009). Experience summarized from North America and Europe:

  • Antenna choice varies. 1-GHz air-coupled horn antennas have worked well in North America. UK and Finnish work got the best thickness data with 400 to 500 MHz antennas. High frequencies scatter in ballast with stones larger than about 2 in. Antennas carried well above the ballast act at a somewhat higher effective frequency than the same antennas on the ground.
  • Dielectric value is the key to ballast quality, and it changes with both fouling and moisture (Table 2.3-25). The surface-reflection method used on pavements to measure the dielectric constant does not work on ballast, so use a CMP or wide-angle survey, or calibrate at crib digs.
  • Survey in frozen conditions where only ballast thickness is wanted. In Finland, freezing removes most of the moisture variation and with it the error in the dielectric value.
  • Run three lines: track center and outside each rail. Where the three records agree the substructure is usually uniform. Where they differ sharply, suspect a problem with track stability on that side (Olhoeft and Selig).
  • Combine methods. The best results came from combining GPR with other measurements: infrared thermography, track stiffness from a loading vehicle, ballast sampling and falling-weight deflection. One early comparison found no link between track stiffness and average GPR amplitude, but later combined analysis was more promising.
  • Detectable geosynthetics. On new construction over karst or old mine workings, a radar-detectable geosynthetic placed in the trackbed lets later GPR surveys show any settlement of that layer.
  • GPR is also used on railroad bridge decks and in tunnels to locate reinforcement, delamination, voids behind linings and water.
Table 2.3-25. Published dielectric values of ballast (as compiled by Clark et al. 2003, in Saarenketo 2009)
ConditionClark et al. (2001)Sussmann et al. (2002), granite
Dry clean ballast33.6
Moist clean ballast3.54
Dry spent (fouled) ballast4.33.7
Moist spent ballast7.85.1
Wet spent ballast38.57.2

These measured values for clean ballast (3 to 4) are now the clean-ballast row of Table 2.3-6, which previously gave 5 to 6. Using 5 to 6 for clean, dry ballast underestimates the velocity and therefore the ballast thickness by roughly 10 to 30%. Use crib-dig or CMP calibration for each survey rather than either table. The two studies also differ widely for wet spent ballast (7 to 39), which shows how much the value depends on the fines, the water and the measurement.

For railroad work: Ask the GPR contractor which antennas will be used and why, how the dielectric value will be calibrated (CMP, crib digs or both), and whether lines will be run outside both rails as well as at the center. Schedule ballast-thickness surveys for frozen, dry or at least stable moisture conditions, and repeat surveys in the same season so the results can be compared. Treat a sharp difference between the three lines as a reason for a crib dig or boring at that location.

Source: Saarenketo, “NDT Transportation,” in Jol (ed.) (2009), Ch. 13, Section 13.8 and Table 13.3. Summarized and paraphrased; particle size converted. Full reference under S19.

Supplemental reference · Leng and Al-Qadi (2010)

What Controls the GPR Signal in Ballast: Laboratory Calibration and Field Check

A GPR depth is only as good as the dielectric constant used to convert travel time to depth. In practice that value is rarely known, and the change from clean to fouled ballast is usually gradual, so it may give no reflection at all. The study summarized here measured the dielectric constant of two ballast types in the laboratory, then used a time–frequency method to find fouling that does not show as a reflector.

Laboratory set-up. Two wooden boxes, 5 × 5 × 4 ft, were built with fiberglass screws so that no metal disturbed the signal. Each was filled with uniformly graded 2.5-in. granite or limestone ballast, oven-dry, compacted to 36.3% air voids (granite) and 37.8% (limestone). Data were collected with 2-GHz air-coupled horn antennas. The ballast was placed in 12-in. lifts. Dry clay was worked into the bottom lift at 10, 25, 40 and 50% of its void volume, clean lifts were added on top to a total of 36 in., and water was then sprayed into the bottom lift at up to 50% of its void volume. The layer thickness was measured at the box corners, so the dielectric constant could be back-calculated from the two-way travel time:

εr = (c · t / 2d)2

where c = 0.984 ft/ns, t = two-way travel time through the layer (ns) and d = layer thickness (ft). This is the depth equation of Section 2.3.9.2 solved for εr, and it is the same calculation used to calibrate a survey at a crib dig (Example 2.3-8).

Table 2.3-26. Laboratory dielectric constant of granite and limestone ballast vs. clay fouling and moisture (2-GHz air-coupled antennas)
BallastCondition variedFitted lineR2εr over the tested range
GraniteDry clay fouling F = 0 to 0.50εr = 3.24 + 1.04 F0.9873.24 to 3.76
LimestoneDry clay fouling F = 0 to 0.50εr = 3.73 + 1.63 F0.9933.73 to 4.55
Granite, 13% fouledWater W = 0 to 0.15εr = 3.96 + 31.9 W0.939about 3.9 to 9.1
Limestone, 13% fouledWater W = 0 to 0.15εr = 4.57 + 39.9 W0.980about 4.2 to 10.5

F = volume of dry clay as a fraction of the ballast void volume; W = volume of water as a fraction of the void volume. The ranges in the last column for moisture are those reported in the text of the paper; the fitted lines give 3.96 to 8.7 for granite and 4.57 to 10.6 for limestone. The paper’s conclusions give 3.96 to 4.84 for dry limestone over 0 to 50% fouling, which does not agree with its own fitted line (3.73 to 4.55); the granite range (3.25 to 3.77) does agree. Use the fitted lines, and read the 0.3 difference as a guide to how closely these values can be relied on. The moisture series also starts higher than the fouling line gives at 13% (3.37 granite, 3.94 limestone) because it was measured on the full 36-in. layered box. All of this is another reason to calibrate each survey rather than take a value from a table.

What the measurements show:

  • Ballast type matters. Limestone has a higher dielectric constant than granite at every fouling level. Calibrate to the rock type on the line; do not carry a value from one quarry source to another.
  • Dry fouling changes the value only a little. Filling half the voids with dry clay raised εr by about 0.5 (granite) to 0.8 (limestone), so dry fouled ballast and clean ballast can look much the same in velocity.
  • Water changes it a lot. The value more than doubles as water rises to 15% of the void volume. Water at only about 2% of the void volume moves εr as much as the whole 0 to 50% fouling range. Wet, fouled ballast is the case GPR finds most easily; dry fouled ballast is the case it can miss.
  • The ballast must be nearly clean for the clean-ballast values to apply. These are bulk values for the whole layer. Table 2.3-6 gives the higher values typical of moist and fouled field ballast.

Reading fouling from a time–frequency plot. A short-time Fourier transform (STFT) breaks the radar trace into short time windows and plots the energy at each frequency against travel time, which converts to depth with the calibrated εr. Three signatures were found (Figure 2.3-74):

  • Clean ballast: the energy fades gradually and smoothly with depth.
  • Fouled ballast: a sudden drop in energy at the top of the fouled zone. In the box, 24 in. of clean ballast over a lift with half its voids filled with clay showed the drop at about 26 in. The clay had settled into the bottom 10 to 11 in. of the lift, filling about 60% of the voids there, rather than filling the top 6 in. completely. The drop therefore marks where fouling becomes heavy, not where fines first appear.
  • Trapped water: a zone of high energy, from the strong reflection at the wet layer.
Depth (in.) 0122436 (a) Clean ballast(b) Fouled zone(c) Trapped water gradual fade sudden energy drop high-energy zone Frequency (low to high) →Frequency (low to high) →Frequency (low to high) → high energylow energySchematic, after the 36-in. laboratory boxes
Figure 2.3-74. The three STFT signatures: (a) gradual attenuation in clean ballast; (b) sudden energy drop at the top of a fouled zone; (c) high-energy zone at trapped water. Schematic drawn for this manual after Leng and Al-Qadi (2010), Fig. 9.

Antenna frequency. The voids in clean 2.5-in. ballast are about the size of the wavelength at 2 GHz (about 3.3 in. in clean, dry granite, where v ≈ 0.55 ft/ns), so the voids scatter the 2-GHz signal and that scatter is itself a sign of clean ballast. At 1 GHz the wavelength is about twice as long and the void scatter is barely visible. Choose 2 GHz where ballast condition is the question and lower frequencies (400 MHz to 1 GHz) where layer thickness and the subgrade are the question.

Field check. Data were collected on a main line of a Class I railroad located in eastern Wyoming, with granite ballast, using 2-GHz air-coupled antennas on a hi-rail vehicle. To reduce reflections from the rails and ties the antennas were carried 2 ft outside the rails, so the records are of the ballast shoulder. Shoulder samples were taken at 6-in. depth intervals for moisture and gradation, and the STFT depths were computed with the laboratory dielectric constant for the measured moisture. Table 2.3-27 compares the two.

Table 2.3-27. Fouling Index by depth from shoulder samples vs. the STFT signature, four field cases (granite ballast)
Case0–6 in.6–12 in.12–18 in.18–24 in.24–30 in.30–36 in.STFT signature
11.71.12.87.87582Energy drop from about 25 in. to 36 in.
200.210687––Energy drop at about 15 in.; high-energy zone at about 20 in. (rain before the survey)
39.25.919.3–––Energy drop at about 17 in.
45.65.013.834.8––Small drop at 11 to 14 in.; large drop at about 18 in.

FI = P4 + P200 (Table 2.3-5). The paper classes FI below 10 as clean, 10 to 20 as moderately fouled and above 20 as seriously fouled. FI can exceed 100 because the No. 200 fraction is also counted in P4. A dash means no sample at that depth.

In every case the energy drop fell in or at the top of the first sample interval classed as moderately or seriously fouled. Because each sample covers 6 in., a high FI shows fouling somewhere in that interval, not at its top. The GPR energy drop may locate the top of the fouling more closely than the samples do.

Limits. The authors warn against overselling the method. Noise from rails, ties and radio signals can hide the ballast information, and the STFT reading assumes a clean record. The laboratory fouling was dry clay; fines from ballast breakdown, coal dust or a pumping subgrade will give other values. The field records were taken on the shoulder, not under the ties. And without a good dielectric constant the depth of the energy drop is no better than the assumed value.

For railroad work: Ask the GPR contractor what dielectric constant was used for each reach and why, and require it to be calibrated at crib digs in each ballast type and moisture condition on the job. Ask for STFT (or similar time–frequency) plots where the clean-to-fouled change is gradual, and have energy drops and high-energy zones entered on the anomaly log (Section 2.3.9.3), with the high-energy zones treated as trapped water and a drainage question. Compare dry-season and wet-season surveys only if the calibration was repeated. Before setting an undercut depth from GPR, confirm the depth at a crib dig or boring, sampling in intervals of 6 in. or less.

Source: Leng, Z. and Al-Qadi, I. L. (2010). “Railroad Ballast Evaluation Using Ground-Penetrating Radar: Laboratory Investigation and Field Validation.” Transportation Research Record 2159, 110–117, Eqs. 1–5, Figs. 7–9, 11, Table 1. Summarized and paraphrased; fitted lines rounded and moisture and fouling expressed as fractions of void volume. Full reference under S5.

Example 2.3-8: Calibrating a GPR Survey at a Crib Dig

A Class I railroad located in Nebraska is planning an undercutting program on a granite-ballasted main line, and a 2-GHz hi-rail GPR survey has been run. Where the fouling is gradual there is no clear reflector, so the depth to the top of the fouled ballast is read from the energy drop on the STFT plot. The contractor converted travel time to depth with an assumed dielectric constant of 5.5. A crib dig at Station A found 14 in. of clean ballast over fouled ballast, and the energy drop there is at a two-way travel time of 4.5 ns. At Station B the drop is at 6.2 ns. The engineer must calibrate the dielectric constant at the dig, find the depth to fouling at Station B, and say how far the contractor’s depth is off.

ties and rail clean granite ballast fouled ballast antennaantenna Station A (crib dig)Station B d = 14 in.t = 4.5 ns dig d = ?t = 6.2 ns GivenCrib dig: d = 14 in., t = 4.5 nsStation B: t = 6.2 nsContractor’s εr = 5.5c = 0.984 ft/nsGranite ballast, 2-GHz antennas RequiredCalibrated εr and velocityDepth to fouling at Station BError in the contractor’s depthIs the calibrated εr reasonable? Black = given; red = required
Given and required for Example 2.3-8.

Given

VariableValueDescription
dA14 in. = 1.167 ftClean ballast thickness measured in the crib dig at Station A
tA4.5 nsTwo-way travel time to the energy drop at Station A
tB6.2 nsTwo-way travel time to the energy drop at Station B
εr,assumed5.5Dielectric constant assumed by the GPR contractor
c0.984 ft/nsSpeed of light
Reference valuesTables 2.3-25 and 2.3-26Measured dielectric constants of clean ballast

Required

  • (a) Calibrated dielectric constant at the crib dig
  • (b) Wave velocity in the clean ballast
  • (c) Depth to the top of the fouled ballast at Station B
  • (d) The depth the contractor reported with εr = 5.5, and its error
  • (e) Whether the calibrated value is reasonable

Equations

  1. Eq. 1: εr = (c t / 2d)2 — back-calculation at a known depth
  2. Eq. 2: v = c / √εr
  3. Eq. 3: d = v t / 2 — two-way time, so halve

Steps

Step 1 · (a) εr at the crib dig (Eq. 1)
(0.984 × 4.5 / (2 × 1.167))2 = (4.428 / 2.333)2 = 1.8982
εr = 3.60
↓
Step 2 · (b) Velocity (Eq. 2)
0.984 / √3.60 = 0.984 / 1.898
v = 0.518 ft/ns
Spot check: back at the dig, 0.518 × 4.5 / 2 = 1.167 ft = 14.0 in.
↓
Step 3 · (c) Depth at Station B (Eq. 3)
0.518 × 6.2 / 2
dB = 1.61 ft = 19.3 in.
↓
Step 4 · (d) Contractor’s depth (Eqs. 2 and 3)
v = 0.984 / √5.5 = 0.420 ft/ns; d = 0.420 × 6.2 / 2 = 1.30 ft
15.6 in.: 3.7 in. (19%) too shallow
Spot check: depth scales with 1/√εr: 19.3 × √(3.60/5.5) = 19.3 × 0.809 = 15.6 in.
↓
Step 5 · (e) Check against measured values
Dry clean granite in the laboratory: 3.24 (Table 2.3-26); moist clean ballast: 3.5 to 4 (Table 2.3-25)
3.60 fits clean, slightly moist granite ballast
↓
Solution
εr = 3.60; v = 0.518 ft/ns; fouling at 19.3 in. at Station B, not 15.6 in.

Solution

(a) εr = 3.60. (b) v = 0.518 ft/ns. (c) The top of the fouled ballast at Station B is 19.3 in. below the top of ballast. (d) With the assumed 5.5 the contractor reports 15.6 in., 3.7 in. (19%) too shallow. (e) The calibrated value is within the range measured for clean, slightly moist ballast.

An error of this size matters for undercutting: a cut set from the contractor’s depth would leave about 4 in. of fouled ballast in place. Because depth scales with 1/√εr, every survey reach needs its own calibration where the ballast type or moisture changes. Granite and limestone differ, and a rain before the survey can raise the value sharply (Table 2.3-26). Here a higher value than 3.60 would make the depth at Station B shallower, and a lower value deeper. The calibration only holds for the clean layer above the energy drop. Below it the fouled ballast has a higher value, so do not use 3.60 to convert deeper reflectors such as the subballast interface. Confirm Station B with a second crib dig before the undercut depth is fixed.

2.3.10 Client-Specific Subgrade Requirements
Table 2.3-7. Track Subgrade Design Requirements
RailroadMin. Ballast Depth (in.)Min. Subballast (in.)Blanket LayerGPR Required?FI ThresholdGoverning Std.
AREMA Min.106Per designCase-by-caseFI > 20AREMA MRE Ch. 1

Owner railroads may set different values. Confirm them against the owner railroad's current standards when the work is scoped.

2.3.11 Worked Calculation Examples
The three examples cover the three questions most often asked of a track section: is the subgrade overstressed, how fouled is the ballast, and will frost reach the subgrade. Each is laid out as Given, Required, Equations, a flow chart of the steps with a spot check at each, and the Solution with what it means for the track.
Example 2.3-1: Stress at the Top of Subgrade Under a Heavy-Haul Main Line

A main line on a Class I railroad located in the Powder River Basin of Wyoming carries unit coal trains at 286,000-lb gross rail load. The client asks whether the subgrade is adequate for the existing section. The method spreads the wheel load through the ballast and subballast to the subgrade and compares the stress there with what the subgrade can carry under repeated loading.

Clay subgrade, su = 350 psfballastsubballastPw = 40,000 lb, DLF 1.4Lt = 8.5 ft, Bt = 11 in.θ = 35°d = 2.0 ftσ at subgrade = ?d needed = ?GivenCooper E-80 wheel 40,000 lbDLF = 1.4Ballast 18 in. + subballast 6 in.Concrete tie 11 in. × 8.5 ftθ = 35°su = 350 psf; FS = 3.0RequiredDynamic load, σ at subgradeAllowable stress; adequate?Granular thickness if notBlack = given; red = required
Given and required for Example 2.3-1.

Given

VariableValueDescription
Pw40,000 lbCooper E-80 wheel load
DLF1.4Dynamic load factor (assumed for heavy tonnage)
db, dsb18 in. and 6 in.; d = 2.0 ftBallast and subballast thickness
Bt0.917 ft (11 in.)Concrete tie width
Lt8.5 ftTie length
θ35° (tanθ = 0.700)Load spread angle through the granular layers
su350 psfSubgrade undrained strength, average of five vane tests
FS3.0Factor of safety for cyclic loading

Required

  • Dynamic wheel load and stress at the top of subgrade
  • Allowable subgrade stress and whether the subgrade is adequate
  • The granular thickness needed if it is not

Equations

  1. Eq. 1: Pd = Pw × DLF — dynamic wheel load
  2. Eq. 2: Aeff = (Bt + 2d tanθ)(Lt + 2d tanθ) — area at the top of subgrade (Section 2.3.2)
  3. Eq. 3: σs = P / Aeff — average vertical stress at the top of subgrade
  4. Eq. 4: σallow = (π + 2) su / FS — allowable stress from undrained bearing capacity
  5. Eq. 5: Solve (0.917 + 1.4d)(8.5 + 1.4d) = Pw / σallow for d — required total granular thickness

Steps

Step 1 · Dynamic wheel load Pd (Eq. 1)
40,000 × 1.4
Pd = 56,000 lb
↓
Step 2 · Effective area Aeff (Eq. 2)
Uses: Bt, Lt, d, tanθ
2d tanθ = 2 × 2.0 × 0.700 = 2.80 ft
(0.917 + 2.80)(8.5 + 2.80) = 3.717 × 11.30
Aeff = 42.0 ft²
Spot check: The load spreads 1.4 ft on each side of the tie, so the area grows from 7.8 to 42 ft².
↓
Step 3 · Stress at the top of subgrade (Eq. 3)
Uses: Pd, Pw, Aeff
Dynamic: 56,000 / 42.0; static: 40,000 / 42.0
σs = 1,333 psf dynamic; 952 psf static
↓
Step 4 · Allowable stress (Eq. 4)
Uses: su, FS
5.14 × 350 / 3.0
σallow = 600 psf
Spot check: 5.14 × 350 = 1,799; 1,799 / 3 = 600.
↓
Step 5 · Adequacy
σallow / σs,static = 600 / 952
Ratio 0.63 < 1.0: overstressed even under static load
↓
Step 6 · Required thickness d (Eq. 5)
A needed = 40,000 / 600 = 66.8 ft²; (0.917 + 1.4d)(8.5 + 1.4d) = 66.8
d = 3.1 ft (37 in.)
Spot check: Check the recommended 38 in. (3.17 ft): A = 5.35 × 12.93 = 69.2 ft²; 40,000 / 69.2 = 578 psf < 600 psf.
↓
Solution
Subgrade overstressed (ratio 0.63); about 37 in. of granular material is needed.

Solution

The subgrade is overstressed: 952 psf static against 600 psf allowable, a ratio of 0.63. About 3.1 ft (37 in.) of ballast, subballast and blanket is needed.

A common section of 12 in. of ballast over 8 in. of subballast (20 in.) is far short. One solution is 24 in. of ballast over a 14-in. granular blanket (38 in. total), which brings the static stress to 578 psf. Where that much section is impractical, improving the subgrade itself, for example by wick drains and preloading (Chapter 7.2), is the alternative. The example compares the allowable stress with the static load because the factor of safety of 3 already allows for repeated loading; using the dynamic stress as well would count the dynamic effect twice.

Example 2.3-2: Ballast Fouling Assessment Along a Segment

A main line segment on a Class I railroad located in Georgia was reported for track geometry deviations. Ballast was sampled at 500-ft intervals over two miles. A single sample says how fouled the ballast is at one point; the pattern along the line says where to clean, where to undercut and where to look deeper.

0102030P4 (No. 4)14.2%P200 (No. 200)3.8%Percent passing (crib sample)FI = P4 + P200 = ? Class = ? Length to clean = ?Six stations at 0.3-mile spacingGivenP4 = 14.2%, P200 = 3.8%Six stations, 0.3 mile apartClasses (Table 2.3-5):moderately fouled 10–20,fouled 20–40, highly fouled ≥ 40RequiredFouling Index and classExtent needing cleaningor undercuttingBlack = given; red = required
Given and required for Example 2.3-2.

Given

VariableValueDescription
P414.2%Percent passing the No. 4 sieve, representative sample
P2003.8%Percent passing the No. 200 sieve, same sample
SamplesSix stations at 0.3-mile spacing (table in Step 3)Along-alignment results
ClassesTable 2.3-5Clean, moderately clean, moderately fouled (10 to 20), fouled (20 to 40), highly fouled (40 or more)

Required

  • Fouling Index and class for the representative sample
  • The extent of ballast needing cleaning or undercutting

Equations

  1. Eq. 1 (Selig): FI = P4 + P200 — Fouling Index

Steps

Step 1 · FI of the representative sample (Eq. 1)
14.2 + 3.8
FI = 18.0: moderately fouled, approaching the cleaning threshold of 20
↓
Step 2 · FI at every station
9.7, 18.0, 27.8, 40.6, 23.0, 13.7 (stations 1 to 6)
Moderately clean, moderately fouled, fouled, highly fouled, fouled, moderately fouled
Spot check: Station 4: 31.4 + 9.2 = 40.6; station 3: 22.1 + 5.7 = 27.8.
↓
Step 3 · Extent above the threshold
Stations 3 to 5 have FI ≥ 20
0.6 mile needs cleaning or undercutting; station 4 (FI 40.6) needs a subgrade investigation
↓
Solution
Representative FI = 18.0; 0.6 mile fouled, peaking at FI 40.6.

Solution

The representative sample has FI = 18.0, moderately fouled. Three consecutive stations are fouled or highly fouled, a 0.6-mile reach that needs ballast cleaning or undercutting.

The peak at station 4 is highly fouled and is the place to look for a ballast pocket or pumping subgrade; three borings there would tell whether undercutting alone is enough. Fouling that rises to a peak and falls again usually has a local source, such as a pumping subgrade or a drainage low point, rather than ballast wear, which is more uniform. At highly fouled locations track modulus often falls below 2,000 psi (Table 2.3-23); confirm it with a deflection measurement before designing the repair.

Example 2.3-3: Frost Blanket for a Frost-Susceptible Subgrade

A main line on a Class I railroad located on the Manitoba prairie crosses lacustrine clay and till, and track geometry defects appear every spring. The aim is to keep the freezing front out of the frost-susceptible subgrade. The example uses a simplified form of the modified Berggren equation; a full design uses the method of Chapter 7.3.

Frost-susceptible till (F3)12 in. ballast + 6 in. subballast = 1.5 ft2 in. XPS insulation (option)32°F isotherm depth = ?Blanket needed = ?FIair = 2,800 °F·daysGivenFI = 2,800 °F·daysExisting NFS cover 1.5 ftSubgrade: F3 tillλ = 0.5 (granular fill)2 in. XPS ≈ 2.5 ft fill (option)Keep 32°F above subgradeRequiredFrost penetration depthBlanket thickness, with andwithout insulationBlack = given; red = required
Given and required for Example 2.3-3.

Given

VariableValueDescription
FIair2,800 °F·daysDesign freezing index (assumed from climate data)
Existing section12 in. ballast + 6 in. subballast = 1.5 ftNon-frost-susceptible cover over the subgrade
SubgradeFrost-susceptible till, group F3Chapter 7.3
λ1.50 in./(°F·day)0.5Assumed coefficient for granular fill; check against Chapter 7.3
Insulation2 in. XPS, equivalent to about 2.5 ft of granular fill (assumed)Optional
CriterionThe 32°F isotherm stays above the top of the subgradeDesign requirement (assumed)

Required

  • Frost penetration depth
  • Blanket thickness needed, with and without insulation

Equations

  1. Eq. 1: X = λ √FI — simplified frost penetration
  2. Eq. 2: dblanket = X − existing cover − insulation equivalent — additional non-frost-susceptible thickness

Steps

Step 1 · Frost penetration X (Eq. 1)
1.50 × √2,800 = 1.50 × 52.9
X = 79.4 in. = 6.6 ft
Spot check: 52.9² = 2,798.
↓
Step 2 · Blanket without insulation (Eq. 2)
6.6 − 1.5
5.1 ft of additional blanket: impractical
↓
Step 3 · Blanket with 2 in. of XPS (Eq. 2)
6.6 − 1.5 − 2.5
2.6 ft (31 in.) of granular blanket
Spot check: 1.5 + 2.5 + 2.6 = 6.6 ft, the full penetration depth.
↓
Solution
31 in. of non-frost-susceptible blanket over 2 in. of XPS insulation.

Solution

Frost penetrates about 6.6 ft. Provide 31 in. of non-frost-susceptible (NFS or F1) granular blanket over 2 in. of XPS insulation board, below the existing subballast.

Without insulation the blanket would have to be over 5 ft thick, which is rarely possible under an operating track. Insulation trades thickness for cost and for a stiffness discontinuity at its ends, which needs tapering. The stress at the top of subgrade must still be checked with the new section (Example 2.3-1). Frost blanket designs are normally submitted under a professional engineer’s seal.

2.3.12 Representative Data Table
Table 2.3-8. Track Subgrade Data Summary — Illustrative Values (hypothetical stations; σ_s static from Section 2.3.2.1 with an 11-in. concrete tie; σ_allow = 5.14 s_u / 3)
StationClientSubgrade USCSs_u (psf)CBRFId_total (in.)σ_s static (psf)σ_allow/σ_sGPR Anomaly
A+00Class ICH3501.8N/A249520.63Mud pocket
B+50Class ISC6204.218.0249521.12Moderately fouled
C+00Class IML4803.127.8249520.86Fouled zone
D+25Class ICL2901.5N/A181,2510.40Wet subgrade
E+75PassengerSP7508.59.7307551.70Moderately clean
F+00Short lineSM9006.813.7249521.62Moderately fouled
G+50Class IML4202.8N/A181,2510.58Frost lens

Material parameters and typical European cross-sections

Table 2.3-17. Average mechanical parameters used in UIC finite-element track models
MaterialE (psi)Poisson’s νc (psi)φ (°)
Poor subgrade (S1)1,7800.42.110
Medium subgrade (S2)3,5600.31.420
Good subgrade (S3)11,4000.3035
Rock subgrade (R)427,0000.221020
Ballast18,5000.2045
Gravel subballast28,4000.3035
Sand14,2000.3030

Values converted from kp/cm² by the authors (1 kp/cm² = 14.22 psi). These are model inputs from UIC test programs, not design values for a specific site.

The cross-sections below show the European layering in practice: 3–5% crossfall on the subballast and subgrade, 2:3 ballast and fill side slopes, and 12 ft track centers to the edge of the formation on a double track with drains and signal/electrification foundations at the shoulder.

Figure 2.3-40. Single track with steel ties: ballast, subballast and subgrade with 3–5% crossfall. Profillidis Fig. 12.7.
Figure 2.3-40. Single track with steel ties: ballast, subballast and subgrade with 3–5% crossfall. Profillidis Fig. 12.7.
Figure 2.3-41. Double track with monoblock concrete ties (Vmax = 155 mph). Profillidis Fig. 12.9.
Figure 2.3-41. Double track with monoblock concrete ties (Vmax = 155 mph). Profillidis Fig. 12.9.

After Profillidis (2014), §8.4.6, Table 8.2, §12.6, Figs. 12.7, 12.9. Full reference under Supplemental References.

2.3.13 Reference Photographs
Flexible Pavement Layers — Subgrade to Asphalt
Flexible Pavement Layers — Subgrade to Asphalt
TxDOT Soil Classes C1–C4 for Embankment and Subgrade
TxDOT Soil Classes C1–C4 for Embankment and Subgrade
Geogrid placement on subgrade
Geogrid placement on subgrade
Track Load Transfer
Track Load Transfer
Cone Penetration Test
Cone Penetration Test
2.3.14 Practical Recommendations
  1. Always compute σ_s before assessing subgrade adequacy. The rail load reaches the subgrade modified by DLF, tie geometry, and layer thickness. Do not use static wheel load alone. With typical dynamic load factors, the dynamic stress is 20–50% higher than the static value.
  2. Use GPR as a screening tool, not a definitive diagnostic. GPR identifies anomalies efficiently over long distances but cannot replace borings for confirmation. Recommend correlation borings at all GPR anomaly stations before designing subgrade remediation.
  3. Design subballast as a filter, not just a filler. Verify Terzaghi filter criteria between subballast and subgrade. A subballast layer that fails the piping criterion will allow subgrade fines to migrate upward, accelerating fouling regardless of its thickness.
  4. Specify ballast quality by procurement source, not just gradation. Los Angeles abrasion and soundness test results are material-specific. Do not assume that any crusher-run angular stone meets AREMA requirements. Require pre-construction materials testing for all ballast sources and track compliance with client engineering standards.
  5. Address drainage first in all subgrade rehabilitation designs. A high fouling index in a well-drained section is a maintenance problem. The same fouling index in a poorly drained section is a structural problem. Restoring drainage often resolves ongoing pumping and progressive shear without requiring additional layer thickness.
  6. For freeze-thaw climates, treat frost blanket design as a geotechnical deliverable, not a construction detail. Submit PE-sealed frost blanket designs with supporting freezing index calculations. Confirm the jurisdiction's seal requirements.
  7. Track modulus data is a valuable project diagnostic. Where the client has track geometry car data or rail deflection measurements, obtain and include this data in the investigation report. Low track modulus zones correlate strongly with subgrade problems and improve boring location selection.
Supplemental reference

Geosynthetics and resilient layers in the trackbed

  • Long-term geogrid performance (a Class I railroad located in Mobile, Alabama). In 1988 a Class I railroad installed multi-layer punched-and-drawn polypropylene geogrid in the ballast and subballast of a 1,000-ft elevated curve that had needed resurfacing every six months or less. The resurfacing interval tripled. Samples exhumed in 2020 — after more than 2 billion gross tons and several floods, including Hurricane Katrina’s 12 ft of water — showed no loss of carbon black and a 45% increase in rib stiffness (Herbert and Gee, 2021).
  • Where geogrid is (and is not) worth it. The USACE WES literature review (Coleman, 1990) concluded that geogrid in ballast can reduce the rate of settlement and differential settlement, but warned against using it simply to reduce ballast thickness on low-density, low-speed track without site-specific justification. Place geogrid deep enough to stay below the tamping tines.
  • Sub-ballast mats. Resilient polyurethane mats placed under the ballast (for example on bridge decks or in tunnels) reduce structure-borne vibration and ballast breakdown on rigid bases. They are a structural/vibration measure and do not substitute for a drained subballast on soil subgrade.

Source: Herbert, D. and Gee, B. (2021). “Durability and Performance of Geogrid-Stabilized Ballast and Sub-ballast Track Section in Mobile, Alabama.” AREMA 2021 Annual Conference · Coleman, D. M. (1990). Use of Geogrids in Railroad Track: A Literature Review and Synopsis. U.S. Army Engineer Waterways Experiment Station, Misc. Paper GL-90 · Getzner Werkstoffe. Sub-Ballast Mats (product technical brochure)

Project management · ASCE (2012)

Resident Representative Duties and Acceptance of In Situ and Procured Materials

ASCE (2012) describes the owner’s resident project representative (RPR) as the person or firm that administers the construction contract on the owner’s behalf. RPR duties may include performing or directing QA, monitoring expenditures and progress payments, pushing timely review of submittals by the designer, evaluating and deciding on unforeseen conditions, coordinating owner site activities such as safety monitoring and testing, building the project record, and negotiating change orders.

The Manual divides materials into two classes. In situ materials are the native soil and rock; their suitability is established by laboratory testing and engineering evaluation, and the results and any retesting go into the project file. Procured materials include natural products such as earth fill and aggregates as well as manufactured items. For each procured material the file should record the qualification procedure and acceptance criteria, test type and date, the signature of the person testing, results, any nonconformance reports and, where specified, where in the structure the tested material was placed. Where workmanship is critical, the contractor may build a mock-up that, once accepted, becomes the standard for the remaining work. Substitutions are accepted only after the designer confirms they meet project objectives, and are then formalized by change order.

On unit-price contracts, common where quantities cannot be known precisely, the RPR and contractor jointly measure completed quantities. The Manual acknowledges that unknown soil conditions can change quantities enough that a unit price must be renegotiated, sometimes with a change in contract time. On lump-sum work the RPR checks that the schedule of values is not unbalanced.

For railroad work: Ballast, subballast, geosynthetics and select fill are procured materials and should be accepted against the railroad’s specification with traceable test records tied to stockpile, delivery ticket and placement station. Native subgrade exposed by undercutting is an in situ material whose acceptance (or further undercut) depends on the engineer’s evaluation at the time, which is a natural role for the RPR. A short test section at the start of a subgrade rehabilitation, accepted on proof rolling and density, can serve as the mock-up that sets the standard for the rest of the work.

Source: American Society of Civil Engineers (2012). Quality in the Constructed Project: A Guide for Owners, Designers, and Constructors, 3rd ed. ASCE Manuals and Reports on Engineering Practice No. 73. Reston, VA: ASCE, pp. 169–175. Summarized and paraphrased. Full reference under Supplemental References.

Project management · Kelly et al. (2004)

Function Analysis and FAST Diagramming for Substructure Remedies

Function analysis is the core of value management. It describes what a project or element must do, as two-word verb–noun pairs, before anyone discusses what it should be. Kelly, Male and Graham have a team brainstorm functions, sort them from high-order needs down to low-order wants, and arrange them in a FAST (Function Analysis System Technique) diagram. Read left to right, the diagram answers “how?”; read right to left, it answers “why?”. A scope line separates the project’s mission from the functions open to brainstorming. In their technical FAST for a river crossing in a park, the mission “facilitate passage across river” leads to the primary function “support people,” with the parallel function “span river” and secondary functions such as “protect people” and “control people.” Design objectives such as “non-slip surface” and “reduce downtime due to flooding” sit above the diagram. Because the team works from functions, the solutions it considers range beyond bridge types: the authors note the answer might be a cable ferry rather than a bridge. For elements, element function analysis has five stages: pick the cost-dominant elements; list every function the element can perform; delete the functions not needed in this context; brainstorm against the functions that remain; and evaluate.

Technical FAST diagram for a river crossing, arranging verb–noun functions along how/why logic with primary, parallel and secondary objectives and design objectives above.
Figure 2-PM1. Technical FAST diagram for a river crossing, arranging verb–noun functions along how/why logic with primary, parallel and secondary objectives and design objectives above. Source: Kelly et al. (2004), Fig. 3.8.

For railroad work: Apply element function analysis to the track substructure before choosing a remedy for a chronic soft spot. The candidate functions of ballast, subballast and subgrade include “distribute load,” “resist shear,” “drain water,” “separate layers,” “restrain track,” “limit frost penetration” and “provide resilience.” Keep only those the investigation shows are failing. If the evidence points to failed “drain water” and “separate layers,” that is, mud-pumping fines with a sound deeper subgrade, the brainstorm should center on drainage and filter or separation solutions, not a deep undercut. If “resist shear” is failing in the subgrade itself, the option set changes. Stating the needed functions explicitly ties the recommendation to the diagnosis and gives reviewers a clear reason why other remedies were set aside.

Source: Kelly, J., Male, S. and Graham, D. (2004). Value Management of Construction Projects. Oxford: Blackwell Science, pp. 62–69, 75–77. Summarized and paraphrased; figures reproduced for internal reference. Full reference under Supplemental References.

Project management · Jacob and Müller (2017)

Building an Earthwork Unit Price from Crew, Equipment and Haul Cycle

Passeck’s chapter in Jacob and Müller builds earthwork unit prices from the bottom up. The direct cost of each bid item is split into five parts: labor, equipment (including fuel and lubricants), materials, third-party services and transport, and site facilities. Percentage surcharges are then added. The example uses 8% general overhead, 6% site overhead, 3% risk and 3% profit, a total of 20%.

The cost components are built up as follows:

  • Labor. The all-in operator wage is the base wage plus premiums, ancillary costs, social costs and imputed costs. In the book’s example these add-ons total 140%, so the all-in rate is 2.4 times the base wage.
  • Equipment. The hourly rate is depreciation, interest and repair, from an equipment register at 170 hours per month, adjusted to market (60% in the example). Fuel and lubricants are added from rated power and specific consumption, plus the operator with a 10% maintenance allowance. For a 77,000-lb excavator the components were about 48% ownership and repair, 24% fuel and 28% operator.
  • Equipment choice by haul distance. Dozer up to about 230 ft, loader up to about 490 ft, scraper up to about 820 ft. Beyond that, excavator, haul units and spreader/compactor work separately. Articulated dumpers suit rough haul roads up to about 1.5 mi, and trucks suit longer hauls on better roads.

Worked haul example (book values converted to US units):

  • Loader output is 327 BCY/hr.
  • Each truck carries 10.5 BCY (13.1 LCY at 25% swell).
  • The one-way haul is 16,400 ft at 13 mph, which is 70% of the 18.6 mph site limit.
  • The cycle is 3 min to load, 2 min to dump and 28.6 min to travel, 33.6 min in all, so each truck makes 1.79 loads/hr, or 18.7 BCY/hr.
  • 327 ÷ 18.7 = 17.5, so 18 trucks are needed.
  • Haul cost per BCY is (18 × truck rate) ÷ 327.
Example 2.3-5: Truck Fleet for a Long Haul

The haul example from Jacob and Müller, in US units. Matching the truck fleet to the loader is the core of an earthwork unit price, and the same arithmetic sizes the haul for undercutting spoil and imported subballast.

Loader327 BCY/hrDumpHaul 16,400 ft at 13 mphReturn 16,400 ft at 13 mphload 3 mindump 2 minTruck: 10.5 BCY (13.1 LCY at 25% swell)Cycle time = ? Output per truck = ? Trucks = ?GivenLoader 327 BCY/hrTruck 10.5 BCYOne-way haul 16,400 ftSpeed 13 mphLoad 3 min, dump 2 minRequiredCycle time, output per truckTrucks to keep the loader busyBlack = given; red = required
Given and required for Example 2.3-5.

Given

VariableValueDescription
QL327 BCY/hrLoader output
c10.5 BCY per truckTruck capacity (13.1 LCY at 25% swell)
L16,400 ft one wayHaul distance
v13 mphHaul speed (70% of the 18.6-mph site limit)
tload, tdump3 min and 2 minFixed times per cycle

Required

  • Cycle time and output per truck
  • Number of trucks to keep the loader busy

Equations

  1. Eq. 1: ttravel = 2L / (88 v) — round-trip travel time in minutes (1 mph = 88 ft/min)
  2. Eq. 2: tcycle = tload + tdump + ttravel
  3. Eq. 3: q = (60 / tcycle) × c — truck output, BCY/hr
  4. Eq. 4: N = QL / q, rounded up — trucks needed

Steps

Step 1 · Travel time (Eq. 1)
2 × 16,400 / (88 × 13) = 32,800 / 1,144
28.7 min
↓
Step 2 · Cycle time (Eq. 2)
3 + 2 + 28.7
33.7 min (33.6 in the source)
↓
Step 3 · Output per truck (Eq. 3)
60 / 33.6 = 1.79 loads/hr × 10.5
q = 18.7 BCY/hr
↓
Step 4 · Number of trucks (Eq. 4)
327 / 18.7 = 17.4
N = 18 trucks
Spot check: 18 × 18.7 = 337 BCY/hr ≥ 327.
↓
Solution
18 trucks.

Solution

Each truck cycles in about 33.6 min and moves 18.7 BCY/hr; 18 trucks keep the loader working.

Travel is 85% of the cycle, which is why haul dominated the unit price in the source. On a railroad the same calculation is made per effective work-window hour, after setup, flagging and clearing, and with on-track or hi-rail haul where trucks cannot cross the live track.

The excavate-haul-place-compact item then added loading (14%), haul (57%), spreading and compaction with one dozer and two rollers (25%), and fine grading (4%). Haul dominated the cost.

The authors stress pricing all earthwork items together, using a mass haul diagram to minimize haul distance and stockpiling, and adjusting manufacturer production figures for soil class, swell and site constraints.

Example mass haul diagram plotting cumulative cut and fill volume against station, used to balance earthwork and find average haul distances (SI units in the original).
Figure 2-PM2. Example mass haul diagram plotting cumulative cut and fill volume against station, used to balance earthwork and find average haul distances (SI units in the original). Source: Jacob and Müller (2017), Figure 1.4.7.

For railroad work: Undercutting and subgrade rehabilitation estimates should be built the same way. The cycle is constrained by track-window length, the number of access points, and on-track or hi-rail haul instead of open haul roads. Haul units cannot cross or foul the live track without protection. Use productivity per effective window hour after setup, flagging and clearing time, not per shift hour. Show spoil disposal (especially fouled ballast) and imported subballast as separate cost lines.

Source: Jacob, D. and Müller, C. (Eds.) (2017). Estimating in Heavy Construction: Roads, Bridges, Tunnels, Foundations. Berlin: Ernst & Sohn, pp. 36–50. Summarized and paraphrased; figures reproduced for internal reference. Full reference under Supplemental References.

Project management · Pratt (2011)

Pricing Undercut, Haul and Imported Subballast: Crew Rates, Fixed Costs and Truck Fleet Size

Pratt prices excavation from productivity and crew cost, and keeps the two separate. Unit cost equals crew-hours per unit times cost per crew-hour. That way a change in wage rates and a change in productivity can each be applied on its own. Applied separately, an 8% wage increase and a 10% productivity loss raise the unit price by 18.8%, not the 18% you get by adding them.

Fixed costs depend heavily on job size. A backhoe that digs 60 CY/h, with $4,000 for transport and set-up, comes to $2.73/CY for equipment on a 3,000-CY job but $14.73/CY on a 300-CY job.

For hauling, Pratt sizes the truck fleet so that the excavator or loader never waits:

Number of trucks = (round-trip travel time + unloading time) / loading time + 1, always rounded up

Loading time is the truck’s bank-measure capacity divided by the loader output. Bank capacity is the loose capacity divided by (1 + swell). In his gravel example, the pit is 16 miles away, trucks average 20 mph and take 5 minutes to unload, so the cycle away from the loader is 101 minutes. A 12-CY truck with 12% swell carries 10.71 bank CY. At 50 BCY/h the loader fills it in 12.85 minutes, so the fleet is 101/12.85 + 1 = 8.86, rounded up to 9 trucks. With a $2.50/CY pit royalty, the delivered gravel costs $16.34 per bank CY. A price quoted per ton is converted using the weight of a compacted cubic yard: $/CY = $/ton × (lb/CY) / 2,000.

Table 2-PM2. Table: Loose and bank weights and compaction factors (after Pratt 2011, Figure 10.2)

MaterialLoose (lb/CY)Bank (lb/CY)Compaction factor
Clay, dry2,5003,10024.0%
Gravel, pit-run, dry2,5502,85011.8%
Sand, dry2,4002,70012.5%
Sand and gravel, dry2,9003,25012.1%

For railroad work: on undercutting and subgrade rehabilitation, the track window usually sets the production rate, not the excavator. Estimate the cubic yards that can be removed and replaced per window. Then size the spoil trucks, side-dump cars or ballast cars with Pratt’s formula, so the machine never waits during a window that has already been paid for. On short jobs, fixed costs (mobilization, work-train set-up, flagging) are spread over a small quantity and dominate the unit price, as Pratt’s 300-CY case shows. Price imported subballast in bank measure, with explicit compaction and waste allowances.

Source: Pratt, D. J. (2011). Fundamentals of Construction Estimating, 3rd ed. Clifton Park, NY: Delmar Cengage Learning, pp. 224–235. Summarized and paraphrased. Full reference under Supplemental References.

2.3.15 Design Checklist

Checklist · Part III · Track Substructure

Design Checklist

Investigation Phase0 of 10
Analysis and Design Phase0 of 8
Deliverable Phase0 of 7
Ticks are saved in this browser.
Plain text version

Investigation Phase

  • [ ] Confirm design train loading (Cooper E-80, GRL, DLF) with client project engineer
  • [ ] Obtain existing as-built track structure details (ballast depth, tie type, subballast)
  • [ ] Request GPR survey data (available from client or commission new survey)
  • [ ] Plan borings at GPR anomaly stations and at representative clean locations
  • [ ] Collect ballast samples for gradation and fouling index (sample at tie base level)
  • [ ] Perform field vane shear tests or collect undisturbed subgrade samples for s_u
  • [ ] Perform CBR tests on subgrade (field or lab per ASTM D1883)
  • [ ] Measure groundwater depth; install piezometers at soft subgrade stations
  • [ ] Assess frost susceptibility of subgrade (USACE FS classification; Chapter 1.3)
  • [ ] Obtain historical geometry car data from client (geometry deviation trends)

Analysis and Design Phase

  • [ ] Calculate σ_s for existing and proposed track section at each boring location
  • [ ] Compute FS_shear at each station; flag stations with FS < 3.0
  • [ ] Compute Fouling Index at each ballast sample location
  • [ ] Design subballast filter (Terzaghi criteria, AREMA Ch. 1)
  • [ ] Design blanket layer thickness (for CBR < 5 or frost-susceptible subgrade)
  • [ ] Compute frost penetration depth (modified Berggren) for projects in seasonal-frost regions
  • [ ] Design edge drain system (pipe size, outlet spacing, geotextile filter)
  • [ ] Check track modulus adequacy (u ≥ client minimum)

Deliverable Phase

  • [ ] Produce along-alignment subgrade characterization table (USCS, s_u, CBR, FI, σ_s, FS)
  • [ ] Flag high-priority rehabilitation stations clearly on plan and profile
  • [ ] Include ballast sampling data table with FI values and classification
  • [ ] Include GPR interpretation map (color-coded fouling zones referenced to station)
  • [ ] Include proposed track section diagram with layer thicknesses and materials
  • [ ] Include GSP language for blanket layer construction, compaction, and testing
  • [ ] PE seal calculations (commonly required)
2.3.16 Cross-Reference Table
TopicSee Also
CBR and subgrade M_r testingChapter 7.3
Frost blanket design (Modified Berggren)Chapter 7.3, Section 7.3.6
Ground improvement for soft subgradeChapter 7.2
Undrained shear strength from VST/CPTChapter 5.1
Consolidation settlement of subgradeChapter 6.2
Bearing capacity of subgrade layerChapter 6.1
Geotechnical Special Provisions (subgrade)Appendix C
Lab testing for subgrade soilsChapter 5.2
2.3.17 Practice Questions
Each question is worked in the same five parts as the examples. Try it from the Given and Required before opening the steps.
Question 2.3-1: Stress at the Top of Subgrade

Problem Statement

A Class I railroad main line on concrete ties carries Cooper E-80 loading. The track section has 14 in. of ballast over 8 in. of subballast, and the railroad uses a dynamic load factor of 1.3. The engineer must find the dynamic wheel load, the effective loaded area at the top of subgrade and the vertical stress on the subgrade.

The same spreading method as Example 2.3-1, for a thinner section and a lower dynamic factor.

SubgradeballastsubballastPw = 40,000 lb, DLF 1.3Lt = 8.5 ft, Bt = 11 in.θ = 35°d = 1.833 ftAeff = ? σ = ?GivenCooper E-80 wheel 40,000 lbDLF = 1.3Ballast 14 in. + subballast 8 in.Concrete tie 11 in. × 8.5 ftθ = 35°Required(a) Dynamic wheel load(b) Effective area at subgrade(c) Vertical stressBlack = given; red = required
Given and required for Question 2.3-1.

Given

VariableValueDescription
Pw40,000 lbCooper E-80 wheel load
DLF1.3Dynamic load factor
d14 in. + 8 in. = 1.833 ftBallast plus subballast
Bt0.917 ft (11 in.)Concrete tie width
Lt8.5 ftTie length
θ35° (tanθ = 0.700)Load spread angle through the granular layers

Required

  • (a) Dynamic wheel load
  • (b) Effective area at the top of subgrade
  • (c) Vertical stress

Equations

  1. Eq. 1: Pd = Pw × DLF — dynamic wheel load
  2. Eq. 2: Aeff = (Bt + 2d tanθ)(Lt + 2d tanθ) — area at the top of subgrade (Section 2.3.2)
  3. Eq. 3: σs = P / Aeff — average vertical stress at the top of subgrade

Steps

Step 1 · (a) Pd (Eq. 1)
40,000 × 1.3
Pd = 52,000 lb
↓
Step 2 · (b) Aeff (Eq. 2)
2 × 1.833 × 0.700 = 2.566 ft; (0.917 + 2.566)(8.5 + 2.566) = 3.483 × 11.066
Aeff = 38.5 ft²
↓
Step 3 · (c) σs (Eq. 3)
52,000 / 38.5
σs = 1,349 psf = 0.67 tsf
Spot check: Example 2.3-1 had a thicker section and a larger DLF and gave a similar 1,333 psf; the two changes nearly cancel.
↓
Solution
(a) 52,000 lb; (b) 38.5 ft²; (c) 1,349 psf.

Solution

(a) Pd = 52,000 lb. (b) Aeff = 38.5 ft². (c) σs = 1,349 psf (0.67 tsf).

Whether 1,349 psf is acceptable depends on the subgrade strength, which is the subject of the next question.

Question 2.3-2: Is the Subgrade Adequate, and How Much Section Is Needed?

Problem Statement

A Class I railroad main line has been losing surface over a clay subgrade where vane tests found the undrained strength shown. Under the existing section the effective area at subgrade level is 42 ft². The engineer must check whether the subgrade is adequate for cyclic loading and, if not, find the granular thickness that would make it adequate.

A stiffer subgrade than Example 2.3-1, with the same section. The question runs the adequacy check and, because the check fails, solves for the thickness that would pass.

Clay subgrade, su = 500 psfballastsubballastPw = 40,000 lb (static)Aeff = 42.0 ft² (existing)θ = 35°d existingσ vs allowable = ?d to meet allowable = ?GivenStatic wheel 40,000 lbAeff = 42.0 ft²su = 500 psf; FS = 3.0Tie 11 in. × 8.5 ft; θ = 35°Required(a) Static stress(b) Allowable stress(c) Adequate?(d) Thickness d neededBlack = given; red = required
Given and required for Question 2.3-2.

Given

VariableValueDescription
su500 psfUndrained strength from vane tests
Pw40,000 lbStatic wheel load
Aeff42.0 ft²Effective area for the existing section
FS3.0For cyclic loading
Bt0.917 ft (11 in.)Concrete tie width
Lt8.5 ftTie length
θ35° (tanθ = 0.700)Load spread angle through the granular layers

Required

  • (a) Static stress
  • (b) Allowable stress
  • (c) Adequacy
  • (d) Thickness d that brings the stress to the allowable

Equations

  1. Eq. 1: σs = Pw / Aeff
  2. Eq. 2: σallow = (π + 2) su / FS
  3. Eq. 3: (0.917 + 1.4d)(8.5 + 1.4d) = Pw / σallow — solve for d

Steps

Step 1 · (a) Static stress (Eq. 1)
40,000 / 42.0
952 psf
↓
Step 2 · (b) Allowable stress (Eq. 2)
5.14 × 500 / 3.0
857 psf
↓
Step 3 · (c) Compare
952 > 857
Not adequate
↓
Step 4 · (d) Required area and thickness (Eq. 3)
A = 40,000 / 857 = 46.7 ft²; solve the quadratic
d = 2.22 ft (27 in.); use 30 in.
Spot check: At d = 2.22 ft: (0.917 + 3.11)(8.5 + 3.11) = 4.03 × 11.61 = 46.7 ft².
↓
Solution
Not adequate; about 27 in. of granular material is needed, so use 30 in.

Solution

(a) 952 psf. (b) 857 psf. (c) Not adequate. (d) d = 2.22 ft (27 in.); use 30 in.

Rounding up to 30 in. allows for placement tolerance and for ballast that will foul over time. The required thickness grows fast as the subgrade weakens: at su = 350 psf (Example 2.3-1) it was 37 in.

Question 2.3-3: Fouling Index of a Ballast Sample

Problem Statement

Track geometry has been deteriorating on a Class I railroad main line, and a ballast sample was taken from the crib. The gradation gave the percentages passing the No. 4 and No. 200 sieves shown. The engineer must compute the Fouling Index, classify the ballast and recommend maintenance action.

0102030P4 (No. 4)17.5%P200 (No. 200)4.2%Percent passing (crib sample)FI = ? Class = ? Action = ?GivenP4 = 17.5%P200 = 4.2%Fouled: FI 20 to 40 (Table 2.3-5)Required(a) Fouling Index(b) Class(c) Recommended actionBlack = given; red = required
Given and required for Question 2.3-3.

Given

VariableValueDescription
P417.5%Passing the No. 4 sieve
P2004.2%Passing the No. 200 sieve
ClassesTable 2.3-5Fouled: FI 20 to 40

Required

  • (a) Fouling Index
  • (b) Fouling class
  • (c) Recommended action

Equations

  1. Eq. 1: FI = P4 + P200

Steps

Step 1 · (a) FI
17.5 + 4.2
FI = 21.7
↓
Step 2 · (b) Class
20 ≤ 21.7 < 40
Fouled
↓
Step 3 · (c) Action
Schedule ballast cleaning; if geometry defects are present, investigate the subgrade with borings
↓
Solution
FI = 21.7, fouled: schedule cleaning.

Solution

(a) FI = 21.7. (b) Fouled. (c) Schedule ballast cleaning (undercutter-cleaner), and investigate the subgrade with borings if track geometry defects are present.

Cleaning restores drainage, but if the fines are coming up from a pumping subgrade they will return. Fines that match the subgrade soil, rather than ballast breakdown, are the sign to look below.

Question 2.3-4: Characteristic Length and Rail Bending Moment

Problem Statement

A Class I railroad main line with 136 RE rail runs on soft track with a modulus of 2,500 psi. The engineer must find the characteristic length of the rail and the maximum bending moment under a 40,000-lb wheel, and explain what soft track does to rail stress.

Soft trackPw = 40,000 lbsprings: track modulus ul = ? Mmax = ?Given136 RE rail, I = 95.0 in.⁴E = 30 × 10⁶ psiu = 2,500 psi (soft track)Pw = 40,000 lbRequired(a) Characteristic length l(b) Maximum rail momentBlack = given; red = required
Given and required for Question 2.3-4.

Given

VariableValueDescription
I95.0 in.4136 RE rail
E30 × 106 psiSteel
u2,500 psiTrack modulus
Pw40,000 lbWheel load

Required

  • (a) Characteristic length l
  • (b) Maximum rail bending moment

Equations

  1. Eq. 1: l = 1/β = (4EI / u)1/4
  2. Eq. 2: Mmax = P l / 4 — single wheel

Steps

Step 1 · (a) l (Eq. 1)
(4 × 30×106 × 95.0 / 2,500)1/4 = (4.56×106)1/4
l = 46.2 in.
Spot check: 46.24 = 4.56 × 106.
↓
Step 2 · (b) Mmax (Eq. 2)
40,000 × 46.2 / 4
Mmax = 462,000 in.-lb = 38,500 ft-lb
↓
Solution
l = 46.2 in.; M = 462,000 in.-lb.

Solution

(a) l = 46.2 in. (b) Mmax = 462,000 in.-lb (38,500 ft-lb).

Softer track (lower u) gives a longer characteristic length and so a larger moment: the rail spans further between effective supports. Compare Example 2.3-7, where u = 3,000 gives l = 44.1 in.

Question 2.3-5: Depth to a GPR Reflector in Ballast

Problem Statement

A hi-rail GPR survey on a Class I railroad main line recorded a strong reflector at a two-way travel time of 8.5 ns, and the ballast is estimated to have the dielectric constant shown. The design section has the ballast and subballast interface at 24 in. The engineer must convert the travel time to depth and say whether the result agrees with the design section.

GPR measures travel time, not depth. The depth depends on the wave velocity, which depends on the dielectric constant of the ballast, and the dielectric constant rises as the ballast fouls and holds water.

Ballast, εr = 6.5SubballastGPR antenna (hi-rail)t = 8.5 ns two-wayDesign interface 24 in.Depth = ? v = ?GivenTwo-way time t = 8.5 nsεr = 6.5c = 0.984 ft/nsDesign interface 24 in. (2.0 ft)Required(a) Wave velocity(b) Depth to reflector(c) Consistent with design?Black = given; red = required
Given and required for Question 2.3-5.

Given

VariableValueDescription
t8.5 nsTwo-way travel time to the reflector
εr6.5Estimated relative dielectric constant of the ballast
c0.984 ft/nsSpeed of light
Design24 in. (2.0 ft)Expected ballast/subballast interface depth

Required

  • (a) Wave velocity
  • (b) Depth to the reflector
  • (c) Whether the result is consistent with the design section

Equations

  1. Eq. 1: v = c / √εr
  2. Eq. 2: d = v t / 2 — two-way time, so halve

Steps

Step 1 · (a) v (Eq. 1)
0.984 / √6.5 = 0.984 / 2.550
v = 0.386 ft/ns
↓
Step 2 · (b) d (Eq. 2)
0.386 × 8.5 / 2
d = 1.64 ft = 19.7 in.
↓
Step 3 · (c) Compare
19.7 in. against 24 in.; εr of 6.5 is above the measured clean range (3 to 4) and the 5 to 6 often assumed, and below moderately fouled (8 to 12), Table 2.3-6
Less ballast than designed, in near-clean ballast
↓
Solution
v = 0.386 ft/ns; d = 19.7 in., about 4 in. less than the design section.

Solution

(a) v = 0.386 ft/ns. (b) d = 1.64 ft (19.7 in.). (c) The reflector is about 4 in. shallower than the design interface.

Either the ballast has settled or the section was built thin. The depth also depends on the assumed dielectric constant: had the ballast been more fouled than assumed, the true depth would be shallower still. A correlation boring or test pit at the station calibrates the dielectric constant and confirms the layer thicknesses.

2.3.18 Case Studies

Field case studies by Burt G. Look, from Earthworks: Theory to Practice – Design and Construction (CRC Press/Balkema, 2023), chosen for this chapter’s topics. Each is summarized from the book with its key figures and a closing note on railroad application added by the authors of this manual. Credit for the case material belongs to Look; see item S13 under Supplemental References.

Case Study 2.18.1 — Zoning the best subgrade material, and losing it in the stockpile
Case study · Look (2023) §14.15

Related section: 2.3.4 Subballast Requirements and Blanket Layer Design

In a 2008 rail project, residual soils in Cut No. 5 (about 40,500 yd³) had their highest CBR in the middle of the cutting, not at depth. Strength does not necessarily increase with depth. Using the CBR 10 material at subgrade level would have reduced layer thickness and the imported capping layer, here the subballast, so it was stockpiled for reuse.

Checks on the stockpile found inconsistent CBR, and inspection showed it had been mixed with poorer material, visible as a change in color. Look’s shorthand for the result: CBR 10 + CBR ≤ 5 ≠ CBR 7; the mix behaves more like CBR 5.

For railroad work: selective excavation and zoning can cut subballast quantities, but only with stockpile control: separate, marked piles, a haul plan, and verification testing of the stockpile before it is placed. Without that, design the subballast for the poorer material.

Spatial variation of CBR in Cut 5 (yield about 40,500 yd³): the best material lies in the middle zone.
Figure 2-LK1. Spatial variation of CBR in Cut 5 (yield about 40,500 yd³): the best material lies in the middle zone. Source: Look (2023), Figure 14.16-1, p. 555.
Stockpile checks: consistent CBR 10 material (top) and inadvertent mixing visible as color change (bottom).
Figure 2-LK2. Stockpile checks: consistent CBR 10 material (top) and inadvertent mixing visible as color change (bottom). Source: Look (2023), Figure 14.16-2, p. 555.

Source: Look, B. G. (2023). Earthworks: Theory to Practice – Design and Construction. CRC Press/Balkema. Case study §14.15, pp. 552–554. Summarized and paraphrased; figures reproduced for internal reference. Full reference under Supplemental References.

Case Study 2.18.2 — Rail formation on broken hard rock: ruts after a week, tests all passed
Case study · Look (2023) §14.13

Related section: 2.3.8 Subgrade Drainage Design

On a 3.7 mi rail alignment around 2008, a short cutting (under 490 ft) hit very high-strength volcanic rock near the surface. With small volumes and no other large cuts, the contractor used a rock breaker, and the work took more than six months. The broken rock surface was uneven and out of tolerance for the required vertical grade. High-quality fill was compacted into the voids to even it out before the capping layer was placed.

Rain followed soon after. No ponding showed at the surface, but water collected in the hollows of the impermeable rock below and could not drain. About a week after completion, construction traffic rutted the formation, although the density and plate load tests had passed. With water trapped in these “bowls”, Skempton’s B is about 1, so each truck pass generated high excess pore pressure. Look’s lessons:

  • Passing strength and density tests do not guarantee against failure, and the failure was not due to material quality.
  • Water must not pond, including where ponding is hidden in an uneven rock surface below the fill.
  • Drainage is needed but hard to achieve everywhere when a rock breaker cannot produce a level surface.
  • Here, a low-strength concrete backfill to give an even, impermeable surface is the better detail.

For railroad work: the same trapped-water mechanism produces mud pumping and track geometry defects where subballast sits on an irregular rock or old hard-pan surface. Shape the rock formation to drain, or level it with lean concrete, before placing subballast.

Ruts formed about one week after completion, under construction traffic.
Figure 2-LK3. Ruts formed about one week after completion, under construction traffic. Source: Look (2023), Figure 14.13-2, p. 551.

Source: Look, B. G. (2023). Earthworks: Theory to Practice – Design and Construction. CRC Press/Balkema. Case study §14.13, pp. 548–550. Summarized and paraphrased; figures reproduced for internal reference. Full reference under Supplemental References.

Author and Sources

Authors: Daniel P. Colwell and Mario Ruel. This chapter was written and compiled by Daniel P. Colwell and Mario Ruel for Railway Ground Hazard Risk Management.

Technical content is drawn from the published sources below, and credit for that material belongs to their authors and publishers. Tables, equations and figures taken from a specific source are also cited where they appear.

Primary sources

Supplemental references

  • Li, D., Hyslip, J., Sussmann, T. and Chrismer, S. (2016). Railway Geotechnics. CRC Press / Taylor & FrancisFind source ↗
  • Usman, K., Burrow, M. and Ghataora, G. (2015). “Railway track subgrade failure mechanisms using a fault chart approach.” Procedia Engineering 125, 547–555 (open access, CC BY-NC-ND 4.0)Find source ↗
  • McHenry, M. and Rose, J. (2012). Railroad Subgrade Performance Indicators — A Review of Available Testing Methods. University of KentuckyFind source ↗Library entry
  • Herbert, D. and Gee, B. (2021). “Durability and Performance of Geogrid-Stabilized Ballast and Sub-ballast Track Section in Mobile, Alabama.” AREMA 2021 Annual ConferenceFind source ↗
  • Leng, Z. and Al-Qadi, I. L. (2010). “Railroad Ballast Evaluation Using Ground-Penetrating Radar: Laboratory Investigation and Field Validation.” Transportation Research Record 2159, 110–117. DOI 10.3141/2159-14Find source ↗
  • Coleman, D. M. (1990). Use of Geogrids in Railroad Track: A Literature Review and Synopsis. U.S. Army Engineer Waterways Experiment Station, Misc. Paper GL-90Find source ↗
  • Getzner Werkstoffe. Sub-Ballast Mats (product technical brochure)Find source ↗Library entry
  • Martland, C. D. (2013). “Introduction of Heavy Axle Loads by the North American Rail Industry.” Journal of the Transportation Research Forum 52(2): 103–125Find source ↗
  • Look, B. G. (2023). Earthworks: Theory to Practice – Design and Construction. CRC Press/Balkema. Case studies §14.13, §14.15Find source ↗Library entry

File locations for these documents are listed under Supplemental References.

Project management sources

  • Seeley, I. H. (1993). Civil Engineering Quantities, 5th ed. Basingstoke: The Macmillan PressFind source ↗
  • American Society of Civil Engineers (2012). Quality in the Constructed Project: A Guide for Owners, Designers, and Constructors, 3rd ed. ASCE Manuals and Reports on Engineering Practice No. 73. Reston, VA: ASCEFind source ↗
  • Kelly, J., Male, S. and Graham, D. (2004). Value Management of Construction Projects. Oxford: Blackwell ScienceFind source ↗
  • Jacob, D. and Müller, C. (Eds.) (2017). Estimating in Heavy Construction: Roads, Bridges, Tunnels, Foundations. Berlin: Ernst & SohnFind source ↗
  • Pratt, D. J. (2011). Fundamentals of Construction Estimating, 3rd ed. Clifton Park, NY: Delmar Cengage LearningFind source ↗
Supplemental References

Material in the green “Supplemental reference” boxes throughout this chapter was added from the following documents in the LEVI geotechnical library. Text is summarized or paraphrased; tables are reproduced with their original source noted; figures are reproduced from the cited document for internal reference use. Consult the original document before relying on a value for design. Blocks marked “After UFC 4-860-01FA (2004)” draw on item S11 and are rewritten for railroad clients. Blocks marked “After Selig & Waters (1994)” summarize item S12 for railroad clients; tables are condensed from the book and its figures are not reproduced. The Case Studies section summarizes case studies from item S13 by Burt G. Look; its figures are reproduced from the book for internal reference use, and the closing “For railroad work” note in each case study is added by the authors of this manual. Blocks tagged “Project management” summarize methods, examples and figures from the project-management, estimating and construction-management books listed here, applied to railroad work; the closing “For railroad work” note in each block is added by the authors of this manual.

  1. Li, D., Hyslip, J., Sussmann, T. and Chrismer, S. (2016). Railway Geotechnics. CRC Press / Taylor & FrancisFind source ↗
  2. Usman, K., Burrow, M. and Ghataora, G. (2015). “Railway track subgrade failure mechanisms using a fault chart approach.” Procedia Engineering 125, 547–555 (open access, CC BY-NC-ND 4.0)Find source ↗
  3. McHenry, M. and Rose, J. (2012). Railroad Subgrade Performance Indicators — A Review of Available Testing Methods. University of KentuckyFind source ↗Library entry
  4. Herbert, D. and Gee, B. (2021). “Durability and Performance of Geogrid-Stabilized Ballast and Sub-ballast Track Section in Mobile, Alabama.” AREMA 2021 Annual ConferenceFind source ↗
  5. Leng, Z. and Al-Qadi, I. L. (2010). “Railroad Ballast Evaluation Using Ground-Penetrating Radar: Laboratory Investigation and Field Validation.” Transportation Research Record 2159, 110–117. DOI 10.3141/2159-14Find source ↗
  6. Coleman, D. M. (1990). Use of Geogrids in Railroad Track: A Literature Review and Synopsis. U.S. Army Engineer Waterways Experiment Station, Misc. Paper GL-90Find source ↗
  7. Getzner Werkstoffe. Sub-Ballast Mats (product technical brochure)Find source ↗Library entry
  8. Martland, C. D. (2013). “Introduction of Heavy Axle Loads by the North American Rail Industry.” Journal of the Transportation Research Forum 52(2): 103–125Find source ↗
  9. Profillidis, V. A. (2014). Railway Management and Engineering, 4th ed. Farnham, UK: Ashgate. Chapters 7–9, 11–13, 16–17, 20 and 22 (track system, mechanical behavior of track, subgrade, sleepers, ballast, transverse effects, maintenance, slab track, electrification foundations, safety)Find source ↗Library entry
  10. Geotechnology for Railroaders Program, Modules 1–8 (two-day training course reference: risk management, geology and soils, ballast and sub ballast, drainage, slides, slope and subgrade stabilization, scour, rock falls, beaver dams, winter problems, spring thaw, extreme weather, earthquakes). Field photographs and figures from the course; slope stabilization process slides adapted from material by D. ColwellFind source ↗
  11. U.S. Army Corps of Engineers, Naval Facilities Engineering Command and Air Force Civil Engineer Support Agency (2004). UFC 4-860-01FA, Railroad Design and Rehabilitation. Unified Facilities Criteria, 16 January 2004 (supersedes TI 850-02, 1 March 2000); approved for public release, distribution unlimited. Used on this page: ch. 2 (§4), ch. 6 (§§5, 8)Find source ↗Library entry
  12. Selig, E. T. and Waters, J. M. (1994). Track Geotechnology and Substructure Management. London: Thomas Telford. Used on this page: chs. 1–3, 5–10, 12, 13 and 16Find source ↗Library entry
  13. Look, B. G. (2023). Earthworks: Theory to Practice – Design and Construction. Leiden: CRC Press/Balkema (Taylor & Francis). ISBN 978-1-032-10470-6. Case studies used on this page: §14.13, §14.15Find source ↗Library entry
  14. Seeley, I. H. (1993). Civil Engineering Quantities, 5th ed. Basingstoke: The Macmillan Press. Used on this page for project-management materialFind source ↗
  15. American Society of Civil Engineers (2012). Quality in the Constructed Project: A Guide for Owners, Designers, and Constructors, 3rd ed. ASCE Manuals and Reports on Engineering Practice No. 73. Reston, VA: ASCE. Used on this page for project-management materialFind source ↗
  16. Kelly, J., Male, S. and Graham, D. (2004). Value Management of Construction Projects. Oxford: Blackwell Science. Used on this page for project-management materialFind source ↗
  17. Jacob, D. and Müller, C. (Eds.) (2017). Estimating in Heavy Construction: Roads, Bridges, Tunnels, Foundations. Berlin: Ernst & Sohn. Used on this page for project-management materialFind source ↗
  18. Pratt, D. J. (2011). Fundamentals of Construction Estimating, 3rd ed. Clifton Park, NY: Delmar Cengage Learning. Used on this page for project-management materialFind source ↗
  19. Jol, H. M. (ed.) (2009). Ground Penetrating Radar: Theory and Applications. Amsterdam: Elsevier. Chapters used: Annan (Ch. 1), Cassidy (Chs. 2 and 5), Doolittle and Butnor (Ch. 6), Saarenketo (Ch. 13). Used on this page: Section 2.3.9Find source ↗
Railway Track Foundation and structure
Railway Track Foundation and structure

Photograph credits

The photographs in this chapter come from the Geo Technology Reference library. Each is credited as stated in its source document; they are reproduced for reference and remain the property of the credited owners.

  1. Photo 2.3.8-1 — Prefabricated geocomposite edge drain (PGED). Koerner et al. (1996). Source: FHWA / SHRP2 R02, GeoTechTools.org technology photo sheet.GeoTechTools.org ↗
  2. Photo 2.3.8-2 — Prime coat application on top of geocomposite membrane. From Elseifi, M., Al-Qadi, I., Loulizi, A., and Wilkes, J. (2001), Transportation Research Record 1772, Figure 2, p. 169. Copyright, National Academy of Sciences, Washington, D.C., 2001. Reproduced with permission of the Transportation Research Board. Source: FHWA / SHRP2 R02, GeoTechTools.org technology photo sheet.GeoTechTools.org ↗
  3. Photo 2.3.8-3 — Geotextile in pavement drainage. From National Highway Institute Lecture notes. Source: FHWA / SHRP2 R02, GeoTechTools.org technology photo sheet.GeoTechTools.org ↗
← Previous · 2.0 The Underworld Chapter 2.2 — Soil and Rock Classification
Next · 2.0 The Underworld → Chapter 2.4 — Silts: Properties, Typical Values and Liquefaction